HVAC JOURNEYMAN EXAM QUESTIONS AND ANSWERS Listed transition ducts f or clothes dryers shall not exceed_____ feet in length. A.3 B.4 C.5 D.6. correct answ-D. Dryers shall not exceed 6 feet in length. UMC Section 504.3.2.1 Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid materials shall be constructed of _____.(A) sheet meta(B) polyvinyl chloride l (C) fiberglass (D) A and C apply correct answ-A. Shall Be Constructed of sheet metal. UMC Section. 5 0 6.1 Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid materials shall be constructed of _____.(A) sheet metal ((B) polyvinyl chloride C) fiberglass (D) A and C apply correct answ-A 511.2 Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less than _____ inches. Is the Answer: A. 10" B. 12" C 16" D. 18". correct answ-D. clearance of an unlisted vented gas fireplace at the sides and the rear not less than 18". UMC Section 908.2(B)

Montrer plus Lire moins
Établissement
Journey
Cours
Journey









Oups ! Impossible de charger votre document. Réessayez ou contactez le support.

École, étude et sujet

Établissement
Journey
Cours
Journey

Infos sur le Document

Publié le
14 février 2025
Nombre de pages
12
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Aperçu du contenu

HVAC JOURNEYMAN EXAM
QUESTIONS AND ANSWERS
Listed transition ducts f or clothes dryers shall not exceed_____ feet in length. A.3 B.4 C.5 D.6.
✅✅correct answ-D. Dryers shall not exceed 6 feet in length. UMC Section 504.3.2.1



Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid
materials shall be constructed of _____.(A) sheet meta(B) polyvinyl chloride l (C) fiberglass (D) A and
C apply ✅✅correct answ-A. Shall Be Constructed of sheet metal. UMC Section. 5 0 6.1



Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust or solid
materials shall be constructed of _____.(A) sheet metal ((B) polyvinyl chloride C) fiberglass (D) A and
C apply ✅✅correct answ-A 511.2



Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less than _____
inches. Is the Answer: A. 10" B. 12" C 16" D. 18". ✅✅correct answ-D. clearance of an unlisted
vented gas fireplace at the sides and the rear not less than 18". UMC Section 908.2(B)



Leaks in gas piping shall be located _____.(A) with a sniffer(B) with a presto-lite flame (C) with a
noncorrosive leak-detecting fluid (D) by increasing the air pressure during a test until the leaks are
heard as a whistle. ✅✅correct answ-C. leaks in a gas piping shall be located with a non corrosive
leak detecting fluid. UMC Section 1316.4.2

Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C)
repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test.
✅✅correct answ-B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3



Every absorption refrigerating system supported from the ground shall rest on a concrete slab
extending not less than _____ the adjoining ground level.(A) 3 inches below(B) 3 inches above (C) 6
inches below(D) 6 inches above. ✅✅correct answ-B. Slab extending not less than 3" above the
adjoining ground level. UMC Section 1106.2



Any part of a venting system installed at an angle greater than 45 degrees from the vertical is
considered by code to be _____.(A) vertica(B) horizontal l (C) a flat vent (D) an offset vent
✅✅correct answ-B. any part of the venting installed at an angle GREATER than 45 degrees is
considered by this code to be Horizontal UMC Section 802.6.1.1

, Condensate drain piping shall have a slope of not less than _____ inch per foot. A 1⁄8" B.¼" C.½" D.
1" ✅✅correct answ-A. Slope of not less than 1/8" per foot. UMC Section 309.1



The minimum gauge or size steel wire used to support horizontal metal ducts 10 inches or less in size
is _____. A.14 AWG B.16 AWG C.18 AWG D.20 AWG ✅✅correct answ-C. 18 Minimum Gauge
note: AWG is the abbreviation for "gauge size" Table 6-7(B)



When smoke detectors are required as part of an automatic shutoff system, they shall be installed in
the _____. A. return air duct ahead of any fresh-air inlet(B) main supply air duct served by such
equipment(C) fresh-air inlet(D) main return and the main supply duct. ✅✅correct answ-B. shall be
installed in the main supply air duct served by equipment. UMC Section 609.0(5)



The largest fuel-burning appliance allowed in a room 100'W x 20'L x 8'H without combustion air
openingsis _____ Btu.(A) 80,000 (C) 140,000(B) 100,000 (D) 320,000 ✅✅correct answ-31 D.
701.2.1



Return air ducts that serve a dwelling unit shall be permitted to be of _____ construction? A.non-
combustible B. combustible C. rated D. none of the above. ✅✅correct answ-B. Shall be permitted
to be of combustible type UMC Section 602.2 Ex (1)



Solid fuel-burning appliances _____ be connected to a venting system that serves a gas- or oil-
burningappliance.(A) shall (B) may (C) shall not(D) with special approval may ✅✅correct answ-C.
appliances shall not UMC Section 802.5.5.1



Any joint obtained by joining of metal parts with alloys that melt at temperatures higher than 840°F,
but lowerthan the melting temperature of the parts to be joined, is a _____ joint.(A) brazed(B) fused
(D) soldered (C) welded ✅✅correct answ-A. Is a brazed joint UMC section 2 1 2.0



A vessel or arrangement of piping or tubing in which vaporized refrigerant is liquefied by removal of
heat is a _____.(A) compressor (C) evaporator(B) generator (D) condenser ✅✅correct answ-D. A
condenser is the piping which vaporizes the refrigerant liquefied by removal of heat, UMC Section 2
0 5.0



is a _____.(A) compressor (C) evaporator(B) generator (D) condenser ✅✅correct answ-18 D 502.0



... ✅✅correct answ-19 C 1313.4

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
PEAKGRADES Chamberlain College Of Nursing
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
26
Membre depuis
2 année
Nombre de followers
6
Documents
4006
Dernière vente
1 mois de cela
PEAK GRADES

Hello everyone...Explore a wide range of Nursing Exams, Test Banks, Study Guides, and other valuable study materials on this page. If you need any additional resources, simply reach out to us, and we’ll deliver them promptly! Please remember to leave a review after your purchase to help us improve customer satisfaction. Thank you

4.3

4 revues

5
2
4
1
3
1
2
0
1
0

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions