ASRT MAMMOGRAPHY MODULE UPDATED ACTUAL Questions and CORRECT Answers Using kVp settings of 20 to 40 creates a lower-energy x-ray beam that results in increased: 1. Scatter Radiation 2. Radiographic Contrast 3. Radiation Dose A. 1 and 2 B. 1 and 3 C. 2 and 3 D. 1, 2, and 3 - CORRECT ANSWER - C. 2 and

Montrer plus Lire moins
Établissement
ASRT
Cours
ASRT

Aperçu du contenu

ASRT MAMMOGRAPHY MODULE
UPDATED ACTUAL Questions and
CORRECT Answers
Using kVp settings of 20 to 40 creates a lower-energy x-ray beam that results in increased:
1. Scatter Radiation 2. Radiographic Contrast 3. Radiation Dose
A. 1 and 2
B. 1 and 3
C. 2 and 3

D. 1, 2, and 3 - CORRECT ANSWER - C. 2 and 3


All of the following are types of filter materials used in mammography, except:
A) molybdenum.
B) rhodium.
C) silver.

D) tungsten. - CORRECT ANSWER - D. Tungsten


Mammography x-ray tubes are oriented so that the strongest part of the x-ray beam is directed to
the patient's:
A. nipple side
B. chest wall side
C. lateral side

D. medial side - CORRECT ANSWER - B. chest wall side


The focal spot sizes used in mammography range between ______ and _____mm.
A. 0.1;0.3
B. 0.3;0.6
C. 0.6;0.9

,D. 0.9;1.2 - CORRECT ANSWER - A. 0.1;0.3


Manual technique are used instead of automatic exposure only when the patient has:
A. dense breast
B. fatty breast
C. a palpable lump

D. breast implants - CORRECT ANSWER - D. breast implants


Which of the following are benefits of using compression in mammography?
1. Increased spatial resolution 2. Uniform radiation exposure 3. Decreased tissue overlap
A. 1 and 2
B. 1 and 3
C. 2 and 3

D. 1, 2, and 3 - CORRECT ANSWER - D. 1, 2, and 3


Which of the following is not a standard function of a picture archiving and communication
system (PACS)?
A. image acquisition
B. image transfer
C. image evaluation

D. image management - CORRECT ANSWER - C. image evaluation


The ACR mammography phantom contains a wax insert that simulates ______cm of breast
tissue.
A. 2.2
B. 3.4
C. 4.2

D. 5.4 - CORRECT ANSWER - C. 4.2

,Which of the following is not a requirement for mammographers under MQSA?
A. passing a criminal background check
B. holding a state license
C. completing 40 hours of mammography instruction

D. performing 200 mammograms every 2 years - CORRECT ANSWER - A. passing a
criminal background check


Diagnostic mammography is used to confirm a diagnosis of breast cancer.
A. True

B. False - CORRECT ANSWER - B. False


________ is especially useful in determining whether a lesion is a solid mass or a fluid-filled
cyst.
A. breast ultrasound
B. breast MR
C. breast-specific gamma imaging

D. digital breast tomosynthesis - CORRECT ANSWER - A. breast ultrasound


A major disadvantage of _________ in breast evaluation is the high false-positive rate from the
exams.
A. digital breast tomosynthesis
B. ultrasound
C. magnetic resonance (MR) imaging

D. molecular imaging - CORRECT ANSWER - C. magnetic resonance (MR) imaging


A milliamperage setting of _____mA is outside of the normal output range of a typical
mammography unit.
A. 20

, B. 40
C. 100

D. 200 - CORRECT ANSWER - D. 200


An interaction with an atom's ______ is most likely to result in photoelectric absorption.
A. K-shell
B. L-shell
C. M-shell

D. N-shell - CORRECT ANSWER - A. K-shell


Compared to molybdenum, rhodium is less desirable for routine use as a mammography target
material because rhodium:
A. has a lower k-edge
B. produces more low-energy bremsstrahlung photons
C. has a higher heat load capacity

D. produces fewer characteristic photons - CORRECT ANSWER - B. produces more low-
energy bremsstrahlung photons


The total filtration requirement of a mammographic tube operating at 30 kVp must be
______mm aluminum (Al) equivalent.
A. 0.25
B. 0.30
C. 0.35

D. 0.40 - CORRECT ANSWER - B. 0.30


To compensate for the relatively short source-to-image distance (SID) used in mammography,
dedicated mammography equipment takes advantage of:
A. the anode heel effect
B. a longer object-to-image distance (OID)

École, étude et sujet

Établissement
ASRT
Cours
ASRT

Infos sur le Document

Publié le
24 décembre 2024
Nombre de pages
31
Écrit en
2024/2025
Type
Examen
Contient
Questions et réponses

Sujets

Faites connaissance avec le vendeur

Seller avatar
Les scores de réputation sont basés sur le nombre de documents qu'un vendeur a vendus contre paiement ainsi que sur les avis qu'il a reçu pour ces documents. Il y a trois niveaux: Bronze, Argent et Or. Plus la réputation est bonne, plus vous pouvez faire confiance sur la qualité du travail des vendeurs.
MGRADES Stanford University
Voir profil
S'abonner Vous devez être connecté afin de suivre les étudiants ou les cours
Vendu
1247
Membre depuis
2 année
Nombre de followers
103
Documents
72988
Dernière vente
11 heures de cela
MGRADES (Genius Brains)

Welcome to MGRADES Exams, practices and Study materials The work speaks for itself Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

197 revues

5
84
4
35
3
50
2
10
1
18

Documents populaires

Récemment consulté par vous

Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Foire aux questions