On low pressure chillers, moisture typically enters the refrigerant system through ans air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: ans 10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller ans ... A hydrostatic tube test kit is used to: ans determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. ans 35% Refrigerant recovery typically start with liquid recovery it is faster. ans ... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: ans 15 psig According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. ans 2.5 mm Hg The primary water source for a recovery unit condensing coil is _____. ans local municipal water supply

Meer zien Lees minder

Voorbeeld van de inhoud

EPA 608 Type 3 questions with correct answers
On low pressure chillers, moisture typically enters the refrigerant system through ans ✓✓ air leaks from areas with gaskets or fittings
The maximum test pressure for leak testing a low pressure centrifugal is: ans ✓✓
10 psig
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-
11 chiller ans ✓✓ ...
A hydrostatic tube test kit is used to: ans ✓✓ determine if a tube leaks
Commercial and industrial process refrigeration systems must be repaired when the
leak rate exceeds ____ of the charge per year. ans ✓✓ 35%
Refrigerant recovery typically start with liquid recovery it is faster. ans ✓✓ ...
A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: ans
✓✓ 15 psig
According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. ans ✓✓ 2.5 mm Hg
The primary water source for a recovery unit condensing coil is _____. ans ✓✓ local municipal water supply When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? ans ✓✓ 16.9" Hg vacuum
After recovering the liquid refrigerant you must: ans ✓✓ recover the vapor refrigerant
According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. ans ✓✓ 100 pounds
Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the: ans ✓✓ system water to freeze
A system does not have to be evacuated all the way to the required level when: ans ✓✓ leaks in the appliance make evacuation to the prescribed level unattainable
Which of the foloowing repairs would ALWAYS be considered "major" under EPA's ans ✓✓ replacement of evaporator coil
Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening the system for a non major repair? ans ✓✓ warming the
refrigerant
If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure appliance to _______ before making a major repair. ans
✓✓ 25 mm of Hg absolute After reaching the required recovery vacuum on a chiller, you should ans ✓✓ Wait for at least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in the oil
The pressure corresponding to 32 F for R-123 ans ✓✓ 20 inches of HG vacuum
When evacuating a system the use of too large a vacuum pump can cause? ans ✓✓ trapped water to freeze
Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: ans ✓✓ 35F
During the evacuation of a system containing large amounts of moisture you can prevent freezing of this moisture by increasing the pressure with______gas ans ✓✓ nitrogen
ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and mechanical ventilation beofre refrigerant concentrations exceed: ans ✓✓ the threshold limit valve and time weighted average
The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning system is set at_______ ans ✓✓ 15 psi
Heat pumps that have been retrofitted from R22 to R407C should be leak checked with: ans ✓✓ pressurized nitrogen
When a new system has been assembled, the first thing to do is: ans ✓✓ pressurize the system with inert gas and leak check

Documentinformatie

Geüpload op
8 mei 2023
Aantal pagina's
17
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BillRanker Tennessee State University
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
197
Lid sinds
2 jaar
Aantal volgers
139
Documenten
7129
Laatst verkocht
3 weken geleden

4.5

65 beoordelingen

5
47
4
10
3
3
2
1
1
4

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen