– I6 STATE CERTIFICATION
EXAMINATION COMPLETE QUESTIONS
AND DETAILED SOLUTIONS LATEST
UPDATE THIS YEAR JUST RELEASED
The California Building Plans Examiner – I6 State
Certification Examination evaluates a candidate's ability
to review construction documents for compliance with
California building regulations, including occupancy
classifications, construction types, structural
requirements, accessibility, fire-resistance features, means
of egress, energy compliance, CALGreen requirements,
permit administration, and plan review procedures. The
examination emphasizes practical code application,
interpretation of construction documents, and identifying
code deficiencies during the review process. Primary
references include California Title 24 regulations,
California Building Code (CBC), California Residential
Code (CRC), California Fire Code (CFC), accessibility
provisions, structural requirements, and plan review
administration procedures.
,Exam Coverage
Plan review administration and permit processing
Construction document completeness verification
Occupancy classification determination
Mixed-use and accessory occupancy requirements
Building height and area limitations
Types of construction and material requirements
Fire-resistance-rated assemblies
Fire barriers and fire partitions
Means of egress calculations
Occupant load determination
Exit access, exits, and exit discharge requirements
Accessibility compliance review
Structural design criteria evaluation
Seismic design requirements
Foundation and soil report review
Floor, wall, and roof system evaluation
Exterior wall requirements
Opening protection requirements
, Fire protection systems review
Mechanical ventilation requirements
Energy efficiency compliance
CALGreen provisions
Site development requirements
Drainage and grading review
Special occupancy provisions
Deferred submittal requirements
Alternate materials and methods review
California-specific amendments and regulations
1.
A plans examiner reviewing a new mixed-use project
should first verify which critical factor before evaluating
specific construction details?
A. Landscaping species selection
B. Occupancy classification and use designation
C. Contractor equipment inventory
D. Parking enforcement procedures
Answer: B
, Rationale: Occupancy classification establishes the code
requirements that govern nearly every other review
component.
2.
A commercial building includes a conference room
expected to accommodate 180 occupants during special
events. Which review activity is most critical?
A. Reviewing paint color schedules
B. Verifying occupant load calculations and egress
capacity
C. Reviewing furniture selection
D. Confirming utility billing accounts
Answer: B
Rationale: Occupant load directly affects egress widths,
exits, and life-safety requirements.
3.
When reviewing structural plans, why should a plans
examiner verify design loads shown on construction
documents?
A. To determine contractor wages
B. To evaluate structural adequacy under expected