Air Conditioning and Heat Pumps Questions And Answers With Latest Study Quiz
- Tentamen (uitwerkingen) • 27 pagina's • 2024
-
Ook in voordeelbundel
-
- €7,68
- + meer info
Which of the following factors affects a customer's level of comfort? 
a. Air movement 
b. Humidity 
c. Temperature 
d. All of the above - Answer-d (All of the above: air movement, humidity, temperature) 
A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible 
capacity of a cooling-only system should be within ____% of this calculated value. 
a. ±10% 
b. +10% 
c. +15% 
d. +30% - Answer-c (+15%) 
The maximum sensible cooling capacity of a heat pump shou...
-
CSLB C10 Test 1 | 120 Questions with 100% Correct Answers
- Tentamen (uitwerkingen) • 8 pagina's • 2022
-
Ook in voordeelbundel
-
- €8,16
- 1x verkocht
- + meer info
What is the minimum working clearance from an electrical panel under 600 V? - 36" Voltage drop in wire is a function of: - Wire gauge, Length of wire, Current flow in the wire A 12-volt direct current, 13-watt fluorescent light is controlled by a photocell. The average daily on-time is 12 hours per day. How many watt-hours are consumed by the light on an average day? - 156 Where may you use nonmetallic-sheathed cable? - inside floors and walls What is the maximum permitted distance between conv...
-
NATE Exam: Air Conditioning and Heat Pumps Study Questions and Answers 2024
- Tentamen (uitwerkingen) • 18 pagina's • 2023
-
- €12,96
- + meer info
Which of the following factors affects a customer's level of comfort? 
 
a. Air movement 
b. Humidity 
c. Temperature 
d. All of the above - d (All of the above: air movement, humidity, temperature) 
 
A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. 
 
a. ±10% 
b. +10% 
c. +15% 
d. +30% - c (+15%) 
 
The maximum sensible cooling capacity of a heat pump should be w...
-
NATE Exam: Air Conditioning and Heat Pumps Exam Questions And Answers
- Tentamen (uitwerkingen) • 21 pagina's • 2024
-
Ook in voordeelbundel
-
- €12,48
- + meer info
NATE Exam: Air Conditioning and Heat Pumps Exam Questions And Answers 
 
Which of the following factors affects a customer's level of comfort? 
 
a. Air movement 
b. Humidity 
c. Temperature 
d. All of the above - ANS d (All of the above: air movement, humidity, temperature) 
 
A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. 
 
a. ±10% 
b. +10% 
c. +15% 
d. +3...
-
NATE Exam Question and answers already passed 2024
- Tentamen (uitwerkingen) • 19 pagina's • 2024
-
Ook in voordeelbundel
-
- €14,40
- + meer info
NATE Exam Question and answers already passed 2024 Which of the following factors affects a customer's level of comfort? 
 
a. Air movement 
b. Humidity 
c. Temperature 
d. All of the above - correct answer d (All of the above: air movement, humidity, temperature) 
 
A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. 
 
a. ±10% 
b. +10% 
c. +15% 
d. +30% - correct...
Wil jij je uitgaves terugverdienen?
-
Nate Heat Pump Test Exam with Verified Answers
- Tentamen (uitwerkingen) • 18 pagina's • 2024
-
- €14,88
- + meer info
Nate Heat Pump Test Exam with Verified 
Answers 
The three processes that transfer heat energy are conduction, convection and 
________ 
a. Concentration. 
b. Radiation. 
c. Refraction. 
d. Static pressure. - CORRECT ANSWER-Radiation 
Which of the following factors affects a customer's level of comfort? 
a. Air movement. 
b. Humidity. 
c. Temperature. 
d. All of the above. - CORRECT ANSWER-All of the above 
A cooling load calculation estimates the sensible heat gain of a structure. The...
-
C957 Unit 3 Module 3 Quiz actual exam with 100% correct answers(latest update)
- Tentamen (uitwerkingen) • 18 pagina's • 2024
-
Ook in voordeelbundel
-
- €14,88
- + meer info
The population of a small town is shown in the following table: 
Year Population 
2000 7,400 
2002 8,300 
2005 9,000 
What was the average rate of change between the years 2000 and 2005, and what is an accurate interpretation of the change? 
A) The average rate of change was 450 people per year. The mayor can anticipate seeing about 450 people a year moving into the town, based on this data. 
B) The average rate of change was -320 people per year. The mayor can anticipate seeing about 320 people...
-
CSLB C10 Test 1 exam part 1/2/3/4 Exam | Questions and Answers Graded A+ Latest 2024/2025
- Tentamen (uitwerkingen) • 25 pagina's • 2024
-
- €12,00
- + meer info
CSLB C10 Test 1 exam part 1/2/3/4 Exam | 
Questions and Answers Graded A+ Latest 
2024/2025 
What is the minimum working clearance from an electrical panel under 600 V? 
36" 
Voltage drop in wire is a function of: 
Wire gauge, Length of wire, Current flow in the wire 
A 12-volt direct current, 13-watt fluorescent light is controlled by a photocell. 
The average daily on-time is 12 hours per day. How many watt-hours are 
consumed by the light on an average day? 
156 
Where may you use nonmet...
-
CSLB C10 Test 1 | 120 Questions with 100%Correct Answers Already Passed.
- Tentamen (uitwerkingen) • 39 pagina's • 2024
-
- €11,04
- + meer info
CSLB C10 Test 1 | 120 Questions with 100%Correct Answers Already Passed. 
What is the minimum working clearance from an electrical panel under 600 V? 
36" 
Voltage drop in wire is a function of: 
Wire gauge, Length of wire, Current flow in the wire 
A 12-volt direct current, 13-watt fluorescent light is controlled by a photocell. The average daily 
on-time is 12 hours per day. How many watt-hours are consumed by the light on an average day? 
156 
Where may you use nonmetallic-sheathed cable? 
i...
-
CSLB B GENERAL EXAM 2024 WITH 100% CORRECT ANSWERS
- Tentamen (uitwerkingen) • 17 pagina's • 2024
-
- €15,84
- + meer info
what size of a circuit breaker can be installed on a line with 7 outlets 14 AWG wire? - correct answer 15 amp; according to code, the conductor ampacity rating for a 14 gauge wire is 15 amps. for 12 gauges wire is 20 amps. the number of outlets does not determine the size of circuit breaker. 
 
how many roof squares are in the roof measuring 45' by 50'? - correct answer 22.5; (45x50) / 100 (roofing squares made of 10'x10'). 
 
total drop for a 120' pipe with a 2% slope? - correct answe...