How is the cooling effect in a mechanical refrigeration system produced? - 
Evaporation of liquid refrigerant into vapor 
What is the primary purpose of a compressor? - It circulates and 
pressurizes the refrigerant vapor before the vapor Is condensed for re use 
Name another function that must be performed by the compressor - 
Is raise the pressure and temperature of the refrigerant vapor. This 
allows the refrigerant to ...
Exam (elaborations)
Commercial Refrigeration Certification Exam Questions and Answers 100% Pass
perate at high efficiency. 
B. ensure that frost does not accumulate. 
C. sub-cool the compressor. 
D. ensure proper oil return. - A. operate at high efficiency. 
The difference between the temperature of the refrigerant boiling in the 
evaporator and the temperature at the evaporator outlet is known as: 
A. evaporator superheat. 
B. latent heat. 
C. evaporator sub-cooling. 
D. sublimation. - A. evaporator superheat. 
An expansion device that is stuck open will cause: 
A. low suction pressure
Package deal
Commercial Refrigeration Exams Compiled (Package Deal) With Complete Solutions
Commercial Refrigeration Exams Compiled (Package Deal) With Complete Solutionscommercial Refrigeration Exams Compiled (Package Deal) With Complete Solutionscommercial Refrigeration Exams Compiled (Package Deal) With Complete Solutionscommercial Refrigeration Exams Compiled (Package Deal) With Complete Solutionscommercial Refrigeration Exams Compile
Exam (elaborations)
Commercial Refrigeration FINAL TEST 2024/2025 Questions and Answers (Graded A)
Commercial Refrigeration FINAL TEST 2024/2025 Questions and Answers (Graded A)Commercial Refrigeration FINAL TEST 2024/2025 Questions and Answers (Graded A)Commercial Refrigeration FINAL TEST 2024/2025 Questions and Answers (Graded A)Commercial Refrigeration FINAL TEST 2024/2025 Questions and Answers (Graded A) 
How is the cooling effect in a mechanical refrigeration system produced? - ANSWER - Evaporation of liquid refrigerant into vapor 
 
What is the primary purpose of a compressor? - ANSWER ...
Exam (elaborations)
Commercial Refrigeration Units 29 and 30 with Complete Questions and Answers
Commercial Refrigeration Units 29 and 30 with Complete Questions and AnswersCommercial Refrigeration Units 29 and 30 with Complete Questions and AnswersCommercial Refrigeration Units 29 and 30 with Complete Questions and Answers 
Which of the following is an indicator of a leaking refrigerant system? - ANSWER - Metal-to-metal contact points. 
 
Why will the compressor on a leaking system become overheated? - ANSWER - There is a reduced amount of coolant. 
 
How are trigger rates established? - A...
Exam (elaborations)
Commercial Refrigeration Unit 16 Questions and Answers 100% Correct
Commercial Refrigeration Unit 16 Questions and Answers 100% CorrectCommercial Refrigeration Unit 16 Questions and Answers 100% CorrectCommercial Refrigeration Unit 16 Questions and Answers 100% CorrectHow deep should the condensate drain trap be? - ANSWER - 3 inches deep (teacher agrees, this answer is bullshit) 
 
Commercial refrigeration equipment for ice cream storage typically uses: - ANSWER - Low temperature evaporators 
 
The wet coil static pressure drop is - ANSWER - Higher than the dry ...
Exam (elaborations)
Commercial Refrigeration Ch 11 (Walk-in System Sizing and Installation) with Complete Solutions
Commercial Refrigeration Ch 11 (Walk-in System Sizing and Installation) with Complete SolutionsCommercial Refrigeration Ch 11 (Walk-in System Sizing and Installation) with Complete SolutionsCommercial Refrigeration Ch 11 (Walk-in System Sizing and Installation) with Complete SolutionsCommercial Refrigeration Ch 11 (Walk-in System Sizing and Installation) with Complete Solutions 
Four inches of urethane insulation is equivalent to how many inches fiberglass insulation? - ANSWER - 10 inches 
 
Why...
Exam (elaborations)
Commercial Refrigeration Final Exam Questions From Quizzes with 100% Correct Answers
Commercial Refrigeration Final Exam Questions From Quizzes with 100% Correct AnswersCommercial Refrigeration Final Exam Questions From Quizzes with 100% Correct AnswersCommercial Refrigeration Final Exam Questions From Quizzes with 100% Correct Answers___ are snap-acting valves that open and close very fast when the electrical energy is applied to the coil. - ANSWER - Solenoid valves 
 
A suction line accumulator is used to ensure that liquid refrigerant enters the compressor. - ANSWER - False 
...
Exam (elaborations)
Commercial refrigeration Chapter 10 Questions and Answers 100% Correct
Commercial refrigeration Chapter 10 Questions and Answers 100% CorrectCommercial refrigeration Chapter 10 Questions and Answers 100% CorrectCommercial refrigeration Chapter 10 Questions and Answers 100% Correct 
What is the proper temperature of a meat case? - ANSWER - 28 to32° 
 
What is a parallel rack system - ANSWER - A system of multiple compressors that share a common source of refrigerant and oil to refrigerate a group of cases. 
 
Why are parallel rack systems used in supermarket refrig...
Exam (elaborations)
Commercial Refrigeration Exam Questions and Answers (Graded A)
Commercial Refrigeration Exam Questions and Answers (Graded A)Commercial Refrigeration Exam Questions and Answers (Graded A)Commercial Refrigeration Exam Questions and Answers (Graded A)Commercial Refrigeration Exam Questions and Answers (Graded A) 
The defrost cycle is normally terminated - ANSWER - Based on either temperature, pressure, or time 
 
Why would a 35 degree meduim temperature case need to defrost? - ANSWER - The coil temperature for a 35 degree box opertes below freezing 
 
The low...
Exam (elaborations)
Commercial Refrigeration Chapter 8 Review Questions and Answers 100% Correct
Commercial Refrigeration Chapter 8 Review Questions and Answers 100% CorrectCommercial Refrigeration Chapter 8 Review Questions and Answers 100% CorrectCommercial Refrigeration Chapter 8 Review Questions and Answers 100% CorrectCommercial Refrigeration Chapter 8 Review Questions and Answers 100% Correct 
What are the two main weaknesses of 3Ø motors? - ANSWER - Phase loss and voltage imbalance. 
 
What formula is used to measure the percentage of voltage unbalance? - ANSWER - Vu = Vd ÷ Va 
 
W...
Exam (elaborations)
Commercial Refrigeration Final Study Guide with Complete Solutions
Commercial Refrigeration Final Study Guide with Complete SolutionsCommercial Refrigeration Final Study Guide with Complete SolutionsCommercial Refrigeration Final Study Guide with Complete SolutionsCommercial Refrigeration Final Study Guide with Complete Solutions 
The evaporator in a refrigeration system must be colder Than the refrigerated space in order to absorb heat. - ANSWER - True 
 
The rule of thumb for low temperature refrigeration is 5 degrees superheat. - ANSWER - True 
 
Capillary t...
Exam (elaborations)
Commercial Refrigeration Ch 1 & 2 Questions and Answers 100% Correct
Commercial Refrigeration Ch 1 & 2 Questions and Answers 100% CorrectCommercial Refrigeration Ch 1 & 2 Questions and Answers 100% CorrectCommercial Refrigeration Ch 1 & 2 Questions and Answers 100% CorrectCommercial Refrigeration Ch 1 & 2 Questions and Answers 100% CorrectWhat is considered the "normal" box temperature of a walk-in refrigerator? - ANSWER - 35°F-37°F 
 
What is considered the "normal" box temperature of a reach-in refrigerator? - ANSWER - 38°F-40°F 
 
What is considered th...
Exam (elaborations)
Exam (elaborations) Commercial Refrigeration
5%️️If converting from mineral oil to POE oil, what is considered to be the industry standard 
for residual mineral oil content? 
Refractometer 
Oil conversion test kit️️When converting to POE from mineral oil, what can be used to 
determine residual mineral oil content? 
Global warming potential (GWP)️️Some refrigerants are now being phased out due to their 
HCFC️️Which currently used refrigerant category is quickly disappearing due to its ozone 
depletion potential? 
404a️️...
Exam (elaborations)
Commercial Refrigeration Final Study Guide A+ GRADED QUESTIONS AND ANSWERS/2024
Commercial Refrigeration Final Study Guide A+ GRADED QUESTIONS AND ANSWERS/2024
Exam (elaborations)
Commercial Refrigeration Final Study Guide Questions And Correct Answers Verified Latest 2023-2024 Grade A +
Commercial Refrigeration Final Study Guide Questions And Correct Answers Verified Latest Grade A + 
Commercial Refrigeration Final Study Guide Questions And Correct Answers Verified Latest Grade A + 
Commercial Refrigeration Final Study Guide Questions And Correct Answers Verified Latest Grade A +
Exam (elaborations)
Refrigeration Air Conditioning Work Ready Certification Exam Questions and Answers
Refrigeration Air Conditioning Work Ready Certification Exam Questions and Answers
Exam (elaborations)
Commercial Refrigeration Exam Questions with Complete and Correct Answers
Commercial Refrigeration Exam Questions with Complete and Correct Answers
Exam (elaborations)
Commercial refrigeration mid term Exam Questions and Answers