2025 IRC EXAM PART 3 QUESTIONS WITH CORRECT ANSWERS 2025/2026

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
19-12-2025
Written in
2025/2026

2025 IRC EXAM PART 3 QUESTIONS WITH CORRECT ANSWERS 2025/2026

Institution
IRC
Course
IRC









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IRC
Course
IRC

Document information

Uploaded on
December 19, 2025
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

2025 IRC EXAM PART 3 QUESTIONS
WITH CORRECT ANSWERS 2025
Photoelectric smoke alarms shall not be installed less than feet horizontally from a per
manently installed cooking appliance.

Ionization alarm separation distance is feet, and ionization alarms with a silencing button i
s __________ feet. - CORRECT ANSWER -6

20

10



Section R314 3.1 Installation near cooking appliances, Item 3.



Smoke alarms shall receive their primary power from the building wiring where such wiring is served f
rom a commercial source and, where primary power is interrupted, shall receive power from a
. - CORRECT ANSWER -battery



Section R314.6 Power source.



Physical interconnection of smoke alarms shall not be required where
alarms are installed. - CORRECT ANSWER -listed wireless

(all alarms must sound upon activation of one alarm)



Section R314.4 Interconnection.



Smoke alarms are required in each .

Smoke alarms are required outside each separate .

Smoke alarms are required on each additional story of the dwelling, including and
and not including and .-
CORRECT ANSWER -sleeping room

sleeping area

basements, habitable attics

crawl spaces, uninhabitable attics

, R314.3 Smoke Alarms - Location



Carbon monoxide alarms shall be installed outside of each separate in
the immediate vicinity of the . - CORRECT ANSWER -sleeping area

bedrooms

(CO alarms are not required if there are no fuel-fired appliances and no attached garage)



Section R315.3 Location



When a -
is located within a bedroom or its attached bathroom, a carbon monoxide al
arm shall be installed within the bedroom. - CORRECT ANSWER -fuel-burning appliance



R315.3 Carbon Monoxide Alarms - Location



Foam plastic insulation installed at 4 inches in thickness or less shall have a flame spread index of not
more than and a smoke-developed index of not more than .-
CORRECT ANSWER -75

450



Section R316.3.1 Foam plastic insulation 4 inches thick or less.



Foam plastic shall be separated from the interior of a building by an approved
of not less than -inch gypsum wallboard. - CORRECT ANSWER -
thermal barrier

1/2



Section R316.4 Thermal barrier.



A thermal barrier is not required for foam plastic insulation in an attic that is entered only for purpose
s of or . - CORRECT ANSWER -repairs
$13.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
Kelex

Get to know the seller

Seller avatar
Kelex stuvia
View profile
Follow You need to be logged in order to follow users or courses
Sold
New on Stuvia
Member since
1 month
Number of followers
0
Documents
101
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions