Questions And Correct Answers
(Verified Answers) Plus Rationale2026
Q&A| Instant Download Pdf
1. What is the minimum wire size allowed for a 20-ampere branch circuit
supplying general lighting in a dwelling?
A. 14 AWG
B. 12 AWG
C. 10 AWG
D. 8 AWG
Rationale: 12 AWG copper wire is the minimum size for a 20-ampere
general lighting branch circuit according to the National Electrical
Code (NEC).
2. What is the standard residential voltage for most household
appliances in Illinois?
A. 120 V
B. 208 V
C. 120/240 V
D. 277 V
Rationale: Most residential homes use 120/240 volts single-phase
service for standard appliances and outlets.
3. According to the NEC, how many disconnecting means are required for
a single-family dwelling service?
A. None
B. One
C. Two
D. Three
, Rationale: A single-family dwelling requires at least one main
disconnecting means to shut off all power to the building safely.
4. Ground-fault circuit interrupters (GFCIs) are required in which areas of
a dwelling?
A. Bedrooms only
B. Bathrooms, kitchens, garages, and outdoor outlets
C. Living rooms
D. Attics
Rationale: NEC requires GFCIs in locations with increased risk of
electric shock, such as bathrooms, kitchens, garages, and outdoor
outlets.
5. What is the purpose of an arc-fault circuit interrupter (AFCI)?
A. Reduce voltage
B. Prevent fires caused by arcing faults
C. Protect from ground faults
D. Increase current
Rationale: AFCIs detect arcing conditions in wiring and prevent fires
caused by electrical arcs.
6. The maximum number of 12 AWG conductors allowed in a 3/4-inch
EMT conduit is:
A. 4
B. 5
C. 6
D. 7
Rationale: According to NEC conduit fill tables, 6 conductors of 12
AWG can fit safely in a 3/4-inch EMT.
7. Which type of grounding electrode is required for a residential
service?
A. Water pipe only
B. Metal underground water pipe, concrete-encased electrode, or
ground rod
C. Plastic pipe
D. None
Rationale: NEC specifies acceptable grounding electrodes such as
metal water pipes, concrete-encased electrodes, or ground rods.
, 8. What color is typically used for a grounded (neutral) conductor?
A. Black
B. Red
C. White
D. Green
Rationale: White or gray insulation is designated for grounded
(neutral) conductors in residential wiring.
9. Which device is used to protect a branch circuit from overcurrent?
A. Transformer
B. Circuit breaker or fuse
C. Switch
D. GFCI
Rationale: Circuit breakers or fuses interrupt current flow when a
circuit is overloaded or short-circuited.
10. How far above the floor must receptacles be installed in a
kitchen per NEC?
A. 12 inches
B. 15 inches
C. Not more than 48 inches above the countertop
D. 60 inches
Rationale: NEC specifies receptacles above countertops should not
exceed 48 inches for accessibility.
11. In a 240 V single-phase circuit, what is the phase-to-phase
voltage?
A. 120 V
B. 240 V
C. 208 V
D. 480 V
Rationale: Single-phase 240 V circuits have 240 volts across the two
hot conductors.
12. Which conductor is used for equipment grounding?
A. Black
B. Red
C. Green or bare copper
D. White