EVITP TEST FINAL EXAM 2025 ACTUAL EXAM COMPLETE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+ Level 2 EVSEs with a rating of 6.6 kilowatts can supply ? of charge current when operating at 220 VAC.

Document preview thumbnail
Preview 3 out of 22 pages

EVITP TEST FINAL EXAM 2025 ACTUAL EXAM COMPLETE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY GRADED A+ Level 2 EVSEs with a rating of 6.6 kilowatts can supply ? of charge current when operating at 220 VAC.

Content preview

EVITP TEST FINAL EXAM 2025 ACTUAL EXAM COMPLETE
EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS
(100% CORRECT ANSWERS) /ALREADY GRADED A+



Level 2 EVSEs with a rating of 6.6 kilowatts can supply ? of charge current when
operating at 220 VAC.
Select one:
a.20 A
b.30 A
c.40 A
d.50 A
b.30 A
What is the minimum branch circuit size for a Level II EVSE with a 32-ampere
current rating?
Select one:
a.32 A
b.35 A
c.40 A
d.55 A
c.40 A

32 A × 1.25 = 40 A minimum OCPD
Two Level II EVSE circuits are installed in the same PVC conduit. Each EVSE is
served by a 40-ampere circuit at 240 volts with an EGC run along with the
circuits. What size copper EGC is required for this installation?
Select one:
a.10 AWG
b.8 AWG

,c.6 AWG
d.4 AWG
a.10 AWG

Note: T250.122 - 40 A Circuit = 10 AWG CU equipment ground
A 32,000 square foot office building has 120 20-ampere, 120-volt duplex
receptacle outlets. What is the branch circuit receptacle load?
Select one:
a.9,600 VA
b.21,600 VA
c.28,000 VA
d.32,000 VA
d.32,000 VA

Note: 220.14(K) - use largest of either 1 VA per square foot or 180 VA per outlet.

180 VA × 120 = 21,600 VA32,000 ft2 × 1

VA = 32,000 VA
An existing 400-ampere, 120/208-volt, 3-phase, 4-wire service has 30 kilovolt-
amperes of non-continuous load and 58 kilovolt-amperes of continuous load.
How much more continuous load can be added to the service? (Note: Use 1.732
for the square root of 3.)
Select one:
a.33,281.92 VA
b.41,436 VA
c.102.5 kVA
d.143.93 kVA
a.33,281.92 VA

Note: 30 kVA + (58 kVA × 1.25) = 102.5 kVA

400 A × 208 V × 1.732 = 144,102.4 VA

, Remaining VA available prior to continuous load correction = 41,602.4 VA

41,602 VA × 0.8 = 33,281.92 VA
A Level II EVSE with a rating of 32 amperes at 208 volts is installed. What is the
minimum size copper equipment grounding conductor required to serve the
installation?
Select one:
a.10 AWG
b.8 AWG
c.6 AWG
d.4 AWG
a.10 AWG

Note: Section 250.122 - the EVSE will be served by a 40A OCPD; therefore, the
minimum size equipment ground will be 10 AWG.
Additional EVSEs are to be added to an existing 120/208-volt, 3-phase, 4-wire,
600-ampere service with 220 amperes of non-continuous load and 172 amperes
of continuous load. The EVSEs each draw 32 amperes. How many new EVSEs can
be added to the service? (Note: Use 1.732 for the square root of 3.)
Select one:
a.2
b.3
c.6
d.9
c.6

220 A + (172 A × 1.25) = 435 A

600 A - 435 A = 165 A

165 A × 0.8 = 132 A left (due to EVSEs being continuous loads)

Document information

Uploaded on
December 18, 2025
Number of pages
22
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NursingTotur2
3.3
(78)
Sold
532
Followers
36
Items
5943
Last sold
8 hours ago


Reviews from verified buyers

3 months ago

Thank you so much for the rating! I truly appreciate your support and feedback — it means a lot. If you’d like to see more high-quality nursing resources and updates, feel free to follow Nursing Tutor 2 here: https://www.stuvia.com/user/NursingTotur2 Thanks again, and wishing you all the best in your studies!



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions