STUDY GUIDE SOLVED QUESTIONS 2026
GRADED A+.
⫸ Multihole, solidback, clusterhole Answer: Trident II Tritanium
shells are offered in the following configuration:
⫸ True Answer: Trident II Tritanium shells utilize the Trident
Locking Mechanism also known as the Innerchange locking
mechanism?
⫸ True Answer: All shell families within the Trident II Acetabular
System are recommended for line-to-line reaming unless adjusted due
to bone quality?
⫸ Interference fit Answer: The trial is windowed for visualization
and assessment of all the following except?
⫸ 6mm Answer: The difference in size (mm) between the ADM
insert OD and ADM cup OD is:
⫸ -May allow surgeons to optimally prepare the femoral canal
-Polished distal lateral relief accommodates all surgical procedures
, -Advanced tooth geometry for efficient removal of bone Answer:
What is/are the potential advantages of the Advanced Broach
Technology?
⫸ True Answer: The dome of the shell is 52mm and the periphery is
53.8 on a PSL Clusterhole HA. PSL 1.8
⫸ False Answer: The PSL and Hemi Clusterhole HA cups are
additive manufacturing.
⫸ Superiorly Answer: When implanting an acetabular shell with
screw holes, the shell should be oriented with the screw holes
positioned __________?
⫸ 37 Answer: Trident II Tritanium features a recessed screw position
which offers an average screw angulation of ______ degrees.
⫸ SOMA Answer: Screw hole patterns for Trident II shells have been
_______-verified to help achieve multiple screws in the safe zone of
the acetabulum.
⫸ Innerchange Answer: The Trident II Acetabular System utilizes the
patented _________ locking mechanism?
⫸ As well as constrained Answer: MDM and X3 can go with all
Trident II