100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA SECTION 608 CORE SECTION EXAM | QUESTIONS AND ANSWERS | VERIFIED ANSWERS | LATEST EXAM

Rating
-
Sold
-
Pages
21
Grade
A+
Uploaded on
03-12-2025
Written in
2025/2026

EPA SECTION 608 CORE SECTION EXAM | QUESTIONS AND ANSWERS | VERIFIED ANSWERS | LATEST EXAM

Institution
EPA SECTION 608 CORE
Course
EPA SECTION 608 CORE










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA SECTION 608 CORE
Course
EPA SECTION 608 CORE

Document information

Uploaded on
December 3, 2025
Number of pages
21
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EPA SECTION 608 CORE SECTION EXAM | QUESTIONS AND
ANSWERS | VERIFIED ANSWERS | LATEST EXAM




Always measure the final system vacuum _____. - CORRECT ANSWER -
With the system isolated from the vacuum pump.


The fill level of a recovery cylinder can be determined by _____. - CORRECT
ANSWER - Mechanical-float or electronic shut off devices/The weight of
cylinder. (Both A&B)


*Which of the following proves that HCFC's are in the stratosphere? -
CORRECT ANSWER - HCFC's found in air samples from the stratosphere.


A system containing a flammable refrigerant must have the process tubes or
service connection marked with a color marking that extends a minimum of
_____ in both directions. - CORRECT ANSWER - 1 Inch.


*Approved refrigerant recovery cylinders have _____. - CORRECT ANSWER
- Yellow tops and gray bodies.


After proper R-410A refrigerant recovery, you should use _____ to leak check
the system. - CORRECT ANSWER - Nitrogen, And if a trace gas is desired,
add a small amount of R-410A. 🌬


The _____ program identifies alternative refrigerants for use - CORRECT
ANSWER - SNAP. (Significant New Alternatives Policy)


An example of an HCFC refrigerant is. - CORRECT ANSWER - R-123.

,_____ refrigerants have the highest ODP. (Ozone Depletion Potential) -
CORRECT ANSWER - CFC's. (Chlorofluorocarbons)


*If R-410A was added to an R-22 system, _____. - CORRECT ANSWER -
Recover the mixture in a separate recovery tank.


_____ means that the refrigerant blend has a range of bubble or dew points at a
constant pressure. - CORRECT ANSWER - Temperature glide. 🌡⛷


When a system is operating, the _____ changes a low-pressure vapor to a high-
pressure vapor. - CORRECT ANSWER - Compressor.


*______ damages stratospheric ozone. - CORRECT ANSWER - HCFC's.
(Hydro-chlorofluorocarbon)


Which refrigerant's must be recovered _____. - CORRECT ANSWER - All
non-exempt refrigerants


Never fill a refillable refrigerant cylinder beyond ________. - CORRECT
ANSWER - 80% of its capacity by weight


Under the EPA's new regulations, when can disposable cylinders be used to
recover refrigerant? - CORRECT ANSWER - Never


A "self-contained" recovery device _____. - CORRECT ANSWER - Removes
refrigerant with the assistance of components in the appliance


What action violates the EPA's prohibition on venting? - CORRECT
ANSWER - Opening the system without properly recovering the refrigerant
first

, ______ Returns refrigerant to a new product specifications and requires
chemical analysis to verify the purity to (Air Conditioning, Heating, &
Refrigeration Institute) AHRI-700 standards. - CORRECT ANSWER -
Reclaiming


When a system is operating, refrigerant enters the compressor of a refrigeration
system as a ______. - CORRECT ANSWER - Superheated Vapor


Which of the following is NOT classified as an A3 refrigerant? - CORRECT
ANSWER - R-1234yf


The service hose between the system and the vacuum pump should ______. -
CORRECT ANSWER - Be as short as possible


Why is venting an "exempt refrigerant" legal? - CORRECT ANSWER -
Because the EPA has determined that the refrigerant does not pose a threat to the
environment if released.


EPA regulations only allow recovered or recycled refrigerant to be ______. -
CORRECT ANSWER - Charged into the same or another appliance owned by
the same person.


All non-exempt refrigerants ______. - CORRECT ANSWER - Must be
recovered before opening or disposing of appliances


What is being done in the U.S. to stop damage to the stratospheric ozone layer?
- CORRECT ANSWER - Eliminating the use of CFC's and HCFC's
refrigerants.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
tutorlorghon University Of Massachusetts
View profile
Follow You need to be logged in order to follow users or courses
Sold
692
Member since
1 year
Number of followers
16
Documents
3559
Last sold
1 week ago
TutorLORGHON

On this page you will find Nursing exams , testbank exams and case study among other many exams. We sell the best exams. Buy and have no regrets.

4.8

233 reviews

5
198
4
22
3
7
2
3
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions