Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 27 pages
Exam (elaborations)

REFRIGERATION EXCELLENCE EXAM 2025/2026 QUESTIONS AND ANSWERS 100% PASS

Document preview thumbnail
Preview 3 out of 27 pages

REFRIGERATION EXCELLENCE EXAM 2025/2026 QUESTIONS AND ANSWERS 100% PASS

Content preview

REFRIGERATION EXCELLENCE EXAM
2025/2026 QUESTIONS AND ANSWERS
100% PASS




1. In a dry type (direct expansion) evaporator, liquid refrigerant must boil away as close to the
end of the coil as possible in order to:

A. Operate at high-efficiency

B. Ensure that Frost is not accumulate

C. Subcool the compressor

D. Ensure proper oil return - ANS A. Operate at high-efficiency



2. The difference between the temperature of the refrigerant boiling in the evaporator and the
temperature at the evaporator outlet is known as

A. Evaporator superheat

B. Latent heat

C. Evaporator sub-cooling

D. Sublimation - ANS A. Evaporator superheat



3. An expansion device that is stuck open will cause

A. Low suction pressure

B. A starved evaporator


1 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

,C. Excessive superheat

D. A flooded evaporator - ANS D. A flooded evaporator



4. When measuring evaporator superheat on a commercial system that has a long suction line,
the pressure reading should be taken at the

A. Compressor inlet

B. Evaporator outlet

C. Condenser outlet

D. Receiver Inlet - ANS A. Compressor inlet



5. Superheat measurements are best taken

A. During a hot pulldown

B. At 8°F two 12°F

C. During defrost

D. With the system operating at design conditions - ANS D. With the system operating at
design conditions



6. A technician is checking the superheat on a multi circuit evaporator and finds one of the
circuits has a superheat that is higher than the others. This could be caused by

A. A dirty coil

B. A refrigerant overcharge

C. Uneven air distribution

D. A blocked distributor - ANS D. A blocked distributor



7. A TXV with an external equalizer is used on

A. Evaporators with a high pressure drop

B. Evaporators with a low pressure drop
2 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

, C. High temperature application is only

D. All evaporators - ANS A. Evaporators with a high pressure drop



8. Dry type evaporators operate most efficiently with the superheat setting of approximately

A. 8°F to 12°F

B. 13°F to 19°F

C. 20°F to 30°F

D. 31°F to 40°F - ANS A. 8°F to 12°F



9. An evaporator used to chill liquids is operating within normal superheat setting. But the
system is not cooling the product properly. Which of the following is most likely the cause?

A. Overcharge of refrigerant

B. Undercharge of refrigerant

C. The circulator

D. The TXV - ANS A. Overcharge of refrigerant



10. What time interval is required between each superheat adjustment?

A. Not less than one hour

B. About 10 to 15 minutes

C. At least a half hour

D. No time delay - ANS B. About 10 to 15 minutes



11. A low temperature evaporator used for cooling space or product refrigeration

A. Is the same as one used for medium or high temperatures

B. Must have fins space closer together

C. Must be frosted periodically

3 @COPYRIGHT 2025/2026 ALLRIGHTS RESERVED.

Document information

Uploaded on
December 3, 2025
Number of pages
27
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar
3.7
(139)
Sold
707
Followers
178
Items
26404
Last sold
3 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions