EPA 608 (TYPE II) Exam Questions and
Answers Graded A+

When a new system has been assembled, the first thing to do is? - Correct answer-

Pressurize the system with an inert gas & leak check.

After installation of a field-piped R-410A split heat pulp, the unit should first be? -

Correct answer-Pressurized with nitrogen then leak checked.

The EPA regulations require that any appliances containing more than 50 pounds

of refrigerant (except for commercial & industrial process refrigeration) must be

repaired when the leak rate exceeds _________ of the charge per year? - Correct

answer-15%

R-410A requires recovery tanks rated for at least? - Correct answer-400 psig

After refrigerant liquid has been recovered from a system, any remaining vapor is?

- Correct answer-Condensed by the recovery system.

Your recovery/recycling machine has R-502 refrigerant in it. You now have to

recover refrigerant from a unit with R-22. What must be done before the R-22



©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

, refrigerant can be recovered/recycled? - Correct answer-Recover as much R-502

from the recovery unit as possible, change filter, & evacuate.

In a refrigeration system with a TXV (or other type of throttling device), the

component directly following the condenser is the? - Correct answer-Receiver

When charging an R-410A system that uses a water-cooled condenser, you must

first charge with vapor to a pressure of at least________, before switching to liquid

charging. - Correct answer-120 psig

Recovered refrigerant may contain what? - Correct answer-1.) Acids




2.) Moisture




3.) Oils

Your recovery/recycling machine has R-22 refrigerant in it. You now have to

recover refrigerant from a unit with R-410A. What must be done before your

recovery unit can be used to recover R-410A? - Correct answer-1.) The recovery

unit must be EPA certified for use with R-410A.




©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

Document information

Uploaded on
December 2, 2025
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.09

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
963
Last sold
-


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions