Terms in this set (146)
According to the AISC Steel High-strength non-shrink
Construction Manual, the grout
used between the column base
plate and the foundation must
be:
According to the AISC Steel ⅜ inch - Table 14-2, Part 14, AISC Steel Construction Manual
Construction Manual, the
minimum washer thickness for a
base plate anchor rod 1 inch
diameter is "BLANK" inches.
,According to the AISC Steel 1-13/16 inches - Table 14-2, Part 14, AISC Steel Construction Manual
Construction Manual, the
recommended maximum size of
anchor rod hole in a base plate
for a 1 inch diameter anchor rod is
"BLANK" inches.
According to the AISC Steel Use steel shims to support the base plate. Page 14-7, Part 14, AISC
Construction Manual, what Steel Construction Manual
should be done if grouting is
delayed on a base plate
supported by leveling nuts until
after steel erection?
According to the AISC Steel treated-hardwood shims
Construction Manual, which of
the following is not an allowed
manner for setting column base
plates?
According to the Code of Wire Brushing - Section 6.5.2 - Code of Standard Practice for Steel
Standard Practice "BLANK" of the Buildings and Bridges
steel surface is required prior to
shop painting.
According to the Code of drift pins, grinding, and reaming. - Section 7.14 - Code of Standard
Standard Practice for Steel Practice for Steel Buildings and Bridges
Buildings and Bridges, "BLANK"
are allowed in moderate amounts
for correction of errors during
steel framing erection.
According to the Code of 1/16 inch - Section 6.4.1 - Code of Standard Practice for Steel
Standard Practice for Steel Buildings and Bridges
Buildings and Bridges, "BLANK" is
the tolerance on the length of a
floor beam that is less than 30
feet long.
, According to the Code of Certified mill test reports - Section 5.2.2 - Code of Standard
Standard Practice for Steel Practice for Steel Buildings and Bridges
Buildings and Bridges, how are
fabricators stock steel material
identified?
According to the Code of It is marked by the supplier - Section 5.1.1, Code of Standard
Standard Practice for Steel Practice for Steel Buildings and Bridges
Buildings and Bridges, how is
steel of special material to be
identified?
According to the Code of Steel erection contractor - Section 7.10.3 - Code of Standard
Standard Practice for Steel Practice for Steel Buildings and Bridges
Buildings and Bridges, the
"BLANK" is responsible for the
temporary vertical and lateral
supports necessary for the
erection of the building
framework.
According to the Code of shop and erection drawings - Section 4.4.1 - Code of Standard
Standard Practice for Steel Practice for Steel Buildings and Bridges
Buildings and Bridges, the
"BLANK" must be approved
before the fabrication of the
structural steel begins.
According to the Code of The number specified by the ASTM specification - Section 5.1.1 -
Standard Practice for Steel Code of Standard Practice for Steel Buildings and Bridges
Buildings and Bridges, the
number of samples required to
be tested for structural steel is:
According to the Code of Brushing, Rolling, or spraying - Section 6.5.3 - Code of Standard
Standard Practice for Steel Practice for Steel Buildings and Bridges
Buildings and Bridges, the
permitted method of applying
shop paint is: