100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

CFESA Gas Fitter 2 Practice Test – 2025/2026 Updated Study Guide & Exam Prep | Complete Prep with 100% Pass Guarantee

Rating
-
Sold
-
Pages
60
Grade
A+
Uploaded on
18-11-2025
Written in
2025/2026

Prepare confidently for the CFESA Gas Fitter 2 Exam 2025/2026 with this fully updated study guide and practice test, designed to reinforce essential gas fitting concepts, technical knowledge, and exam readiness. This resource includes: Updated 2025/2026 content covering all major CFESA Gas Fitter 2 exam topics High-quality practice questions with detailed explanations and rationales Effective study strategies for focused preparation Ideal for self-study, classroom review, and exam prep Supports both first-time test takers and retake preparation Why Choose This Guide: Comprehensive coverage of all CFESA Gas Fitter 2 exam domains Practice questions aligned with exam objectives for effective learning Builds confidence and strengthens technical understanding Designed to help students achieve top scores with a 100% pass support approach This CFESA Gas Fitter 2 Practice Test Study Guide 2025/2026 is your complete toolkit to study smarter, master essential concepts, and excel on exam day.

Show more Read less
Institution
Gas Fitter 2
Course
Gas Fitter 2











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Gas Fitter 2
Course
Gas Fitter 2

Document information

Uploaded on
November 18, 2025
Number of pages
60
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Gas Fitter 2 Practice Test – 2025/2026
Updated Study Guide & Exam Prep | 100%
Pass Guarantee


A room heater installed in either a sleeping area or public area shall be:
A. direct vent only
B. equipped with a regulator
C. equipped with a fan
D. equipped with an on / off switch on the wall - correct answerB

What type of vent must be used when the vent of a wall furnace will be concealed in a
partition wall?
A. B vent
B. L vent
C. BH vent
D. BW vent - correct answerD

Single wall vent connectors:
A. may pass through floors, ceilings or roofs provided a metal thimble is used
B. may pass through floors, ceilings or roofs provided the required minimum distance
from combustible material is maintained
C. may pass through floors, ceilings or roofs provided they are insulated
D. shall not pass through floors, ceilings or roofs - correct answerD

BW vent shall be used only with an approved:
A. decorative appliance
B. down flow furnace
C. revertible flue boiler
D. recessed wall furnace - correct answerD

What must be done during the installation of a gas log fireplace?
A. Make sure there is a metal mesh screen in front of the fireplace
B. Secure the chimney damper in the open position
C. Install a pressure regulator
D. Install a metal chimney liner - correct answerB

When can a certified hose be used to connect a construction heater to temporary
piping?
A. Only if a lever handle shut off valve is installed upstream of the hose
B. Only if the hose is 15 feet long

,C. Never - correct answerA

Which of the following is acceptable when a fireplace insert is installed?
A. A metal chimney linear
B. The existing fireplace flue
C. BW vent
D. A tile lined fireplace flue? - correct answerA

An unvented infra-red heater can be installed in ________ application
A. A warehouse
B. A commercial building
C. An industrial building
D. All of the above - correct answerD

Dirt pockets are required on:
A. Decorative appliances
B. Gas logs
C. Room heaters
D. None of the available choices - correct answerD

What diameter and length of a dirt pocket is required when a drop line is 3-inch
diameter?
A. 3 inch diameter by 3 inches long
B. 1 inch diameter by 3 inches long
C. 3/4 inch diameter by 3 inches long
D. 2 inch diameter by 3 inches long - correct answerD

What type of room heater maybe installed in a bathroom?
A. Natural draft
B. Direct fired
C. Forced draft
D. Direct vent - correct answerD

What safety control protects a steam boiler if the condensate pump fails to return water
to the boiler?
A. High pressure limit control
B. Low pressure limit control
C. Flame safeguard control
D. Low water cut off - correct answerD

The relief valve for a residential low-pressure hot water boiler system should be?
A. 14.7 psia
B. 15 psia
C. 30 psig
D. 30 psia - correct answerC

,A backflow prevent used in a boiler system should be located in the:
A. Over flow line connected to the drain
B. Return line close to the boiler
C. 1/4" line connecting the boiler and cushion tank
D. Make up water line to the system - correct answerB

Automatic chlorinators must be installed:
A. upstream of the heater
B. downstream of the heater
C. upstream of the filter
D. downstream of the filter - correct answerB

On seasonal start up, a pool heater should run:
A. intermittently
B. continuously for 24 hours
C. continuously until the thermostat is satisfied
D. one hour on and one hour off until the thermostat is satisfied - correct answerC

Before lighting a burner in a steam boiler, ensure that:
A. there is water in the boiler
B. the temperature controller is set properly
C. the main burner test firing valve is turned on
D. the safety valves are open - correct answerA

The recommended water temperature setting from a mixing valve to the domestic water
system in combination heating systems that employ oil-fired water heaters for heating
potable water and for space heating is:
A. 43°C (110°F)
B. 49°C to 54°C (120°F to 130°F)
C. 60°C to 66°C (140°F to 150°F)
D. 83°C (180°F) - correct answerB

An inverted sensor (measures water level) can be found operating what type of
appliance?
A. Hot water boiler
B. Steam water boiler
C. Domestic hot water storage tank
D. Domestic potable hot water tank - correct answerD

A backflow prevent used in a hydronic heating system is used to:
A. Keep hot water from entering the cold water system
B. Hold the pressure on the system during a temporary shutdown to prevent the entry of
air
C. Prevent the heating water from circulating the wrong way in the system
D. Keep non-combustible water from entering the drinking water system - correct
answerD

, A low water cut off device on an automatically fired hot water heating boiler rated at
350,000 Btuh (102 kW) is:
A. Not required if a limit control is installed
B. Not required if it is installed in the industrial application
C. Required when any portion of the circulating system is located below the boiler
D. Required only in commercial applications - correct answerC

A pressure reducing valve
A. Relieves system pressure in excess of the set pressure
B. Reduces the city main pressure to a safe working pressure
C. Reduces the working pressure to the city main pressure
D. Prevents hot water gravity circulation - correct answerB

The maximum operating pressure of a low pressure steam boiler is
A. 5 psig (35kPa)
B. 15 psig (100 kPa)
C. 100 psig (690 kPa)
D. 150 psig (1035 kPa) - correct answerB

A scotch marine boiler is what type of boiler?
A. Two pass boiler
B. Copper tube boiler
C. Fire tube boiler
D. Four pass water tube boiler - correct answerC

A fire tube boiler has:
A. Water outside the tube and flue gases outside
B. Water inside the tubes and flue gasses outside
C. Water inside the tubes and water outside
D. Water outside the tubes and flue gases inside - correct answerD

Why is a pressure relief valve installed on a pool heater system?
A. To maintain the pool water level
B. To prevent over pressurizing the filter
C. To prevent damage to the system
D. To relieve excess water pressure caused by solar gun - correct answerC

When does an electrically operated automatic vent damper on a mid-efficiency furnace
open?
A. Before the ignition cycle
B. When the furnace is hot
C. At the same time as the gas comes on
D. When the main switch is turned on - correct answerA

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Successscore University Of Phoenix
View profile
Follow You need to be logged in order to follow users or courses
Sold
23
Member since
3 months
Number of followers
0
Documents
1334
Last sold
4 days ago
Ultimate Study Resource | Nursing, HESI, ATI, TEAS, Business & More

Welcome to your one-stop exam prep store!

3.0

3 reviews

5
0
4
2
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions