Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 5 pages
Exam (elaborations)

ESCO Air Conditioning Certification Practice Test Air conditioning Certification practice test | Latest Already Graded A+ UPDATE 2025|2026!!

Document preview thumbnail
Preview 2 out of 5 pages

ESCO Air Conditioning Certification Practice Test Air conditioning Certification practice test | Latest Already Graded A+ UPDATE 2025|2026!!

Content preview

Science Engineering Mechanical Engineering


ESCO Air Conditioning Certification Practice Test Air
conditioning Certification practice test | Latest Already
Graded A+ UPDATE 2025|2026!!
Leave the first rating

Save




Students also studied


JLTV TEST "A" HEAVY TRUCK BRAKES MICHIGAN ... Aviation Test 3 Bmw m

50 terms Teacher 50 terms Teacher 25 terms Teacher




Olivia_Nduku Preview Magentanes Preview lizzmoses724 Preview Ron


 




Terms in this set (88)


What is the movement of heat through Radiation
space called?

A refrigerant release heat when It condenses

Why is it desirable for refrigerant in the To insure liquid refrigerant does not enter the compressor
suction line to be slightly superheated?

A 30 pound cylinder of reclaimed R-22 121 psig
refrigerant has been stored over night at 70
degrees F. What should be the
approximate pressure in the cylinder?

14.7 psia( pouds per square inch absolute) Approximately 0 PSIG
is

What is the main fuction of an air condition To remove heat from the refrigerant
condenser?

Refrigerant R-134a vapor enters the 124 psig (the pressure should not change entering or leaving the condenser)
condenser at 124 psig, 100 degrees F. It
leaves the condenser at 80 degreesF. What
will be the approximate pressure?

Which of the following CANNOT be used Crankcase regulating valve
as a low ambient temperature control?

When testing the efficiency of a (10 seer Approximately 30 degrees F
are lower) air cooled condenser, the
refrigerant condensing temperature should
be no more than_______ higher than the
entering air temperature

, When testing the efficiency of a water 10 degrees F
cooled condenser, the refrigerant
condensing temperature should be no
more _____ higher than the leaving water
temperature.

What does a temperature differential Restricted filter-drier
across a filter-drier indicate?

Which of the following symptoms would be Reduce heat transfer through the walls of the coil
indicative of an oil logged evaporator?

When using an electronic leak detecto, the should be moved at approximately 1 inch per second
sensor probe

Before a vapor / compression system is the refrigerant must be recovered using approved equipment
opened for service

What is the minimum vertical drop from the 3 inches
outlet of the condensate drain pan to the
inlet of the P trap when the evaporator is
ahead of the blower?

The temperature rise method of electric resistive heat air handler
determining air volume CFM is mostly used
with a/an;

What is a sling psychrometer used to wet and dry bulb temperature
measure

A compressor is operating with a discharge 5:1 (235.3+14.7=250) and (35.3+14.7=50) so 250/5=5
pressure of 235.3 psig and a suction
pressure of 35.3 psig. What is the
compression ratio (pumping ratio)?

What method does hot gas bypass refer Capacity control
to?

IF a TEV sensing bulb has lost of its charge, It would cause the low side pressure to decrease
What effect would this have on the air
conditioning system

An increase in water flow, when using a decrease the operating discharge pressure
water cooled condenser, would

The clearance space in reciprocating has an effect on compressor capacity
compressor

What is used to control the flow of water A water regulating valve
on a water-cooled condenser?

How should metallic vibration eliminators parallel to the compressor crankshaft
be installed on a system which uses a
reciprocating compressor?

The total amount of heat contained in one enthalpy
pound of a substance calculated from an
accepted temperature base is called

If non-condensables are trapped in a Increased heat build-up, high amperage and high discharge pressure.
condenser, what symptoms will be
present?

Document information

Uploaded on
November 15, 2025
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$23.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Milestone
5.0
(512)
Sold
3892
Followers
1
Items
1595
Last sold
2 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions