COMMERCIAL SEPTIC SYSTEM INSTALLER EXAM UPDATED QUESTIONS AND ANSWERS All tanks must have: - CORRECT ANSWER2 compartments All tanks whether pre-manufactured or constructed on site shall be constructed so that the length is ___________ compared to the width. - CORRECT ANSWERat least one and one- half (1 1/2) times... "to the width."

Content preview

COMMERCIAL SEPTIC SYSTEM INSTALLER EXAM UPDATED QUESTIONS AND
ANSWERS
All tanks must have: - CORRECT ANSWER✅✅2 compartments



All tanks whether pre-manufactured or constructed on site shall be constructed so that the length is
___________ compared to the width. - CORRECT ANSWER✅✅at least one and one- half (1 1/2) times...
"to the width."



Septic Tanks may be made of: - CORRECT ANSWER✅✅Concrete, Plastic, fiberglass, or other materials as
approved by the department.



Tank compartment partitions will be located: - CORRECT ANSWER✅✅Not less than two-thirds or more
than three-fourths the Length of the tank from the Inlet end.



Compartment partitions will be constructed so a pass-thru hole or slot equal to or greater than the
diameter of the inlet pipe is positioned below the liquid surface with a
_____________________________. - CORRECT ANSWER✅✅Minimum 25% to a maximum of 50% of
the total liquid depth.



Total liquid depth for larger poured-in-place tanks shall have a maximum of ______________inches -
CORRECT ANSWER✅✅66 inches



True or False: Walls and bottom of poured-in-place septic tanks must be reinforced. - CORRECT
ANSWER✅✅True



How can a Septic tank be reinforced? - CORRECT ANSWER✅✅six inch by 6 inch (6"x6") No.10 gage
welded steel reinforcing wire OR fibrous reinforcing material conforming to ASTM specifications for such
materials.



How must Tank Lids be Reinforced? - CORRECT ANSWER✅✅using three-eights steel reinforcing rods
(rebar) which shall be spaced twelve inches (12") on center each way extending a minimum of two and
one half (2 1/2") inches and a maximum of three (3") from the outside edge of the tank lid.

, In general, the tank must be able to withstand a uniform live load of ______________________ pounds
per square foot in addition to all loads to which an underground tank is normally subjected. - CORRECT
ANSWER✅✅150



True or False: Walls, bottoms, and lids of poured-in-place septic tanks should have a minimum thickness
of four inches (4"). - CORRECT ANSWER✅✅True



Tank lids shall be constructed in ______________________ pieces and shall have securable, removable
access openings located so that the inlet and outlet tees can be ________________________________.
- CORRECT ANSWER✅✅one or two,

readily accessed.



Access opening shall have a minimum of _________________ and maximum of ___________________
free space. - CORRECT ANSWER✅✅Minimum: 15"

Maximum: 24"



Tanks with more than 12 inches of cover must extend access openings to within ______ inches of the
ground surface. - CORRECT ANSWER✅✅12



All tanks shall be equipped with ________________________________ rated or equivalent tees at the
inlet and outlet ends of the tank. - CORRECT ANSWER✅✅Four inch (4") PVC, ASTM 3034



Tees shall be constructed so they extend into the liquid a minimum of ____________________ and a
maximum of __________________ of the liquid depth of the tank. - CORRECT ANSWER✅✅Min: 25%

Max: 50%



The invert of the outlet tee shall be located _______________ inches below the invert of the inlet tee. -
CORRECT ANSWER✅✅two inches



__________________ tees shall be equipped with an approved effluent filter. - CORRECT
ANSWER✅✅Outlet

Document information

Uploaded on
November 13, 2025
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STANGRADES
3.4
(14)
Sold
92
Followers
1
Items
12009
Last sold
3 weeks ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions