QUESTIONS WITH COMPLETE SOLUTIONS
“How many BTU's does one gallon of #2 fuel contain? - CORRECT ANSWER 139,000"
"When the viscosity of fuel entering the nozzle increases the_____________ increases: -
CORRECT ANSWER The flow rate also increases"
"Dirt or lint build up on fan blades or air inlet will: - CORRECT ANSWER Reduce the
amount of combustion air"
"High static pressure produced by oil burners: - CORRECT ANSWER Allow
manufacturers to create tighter heat exchangers for increasedefficiency"
"High static pressure burners have been developed to: - CORRECT ANSWER to push
the products of combustion through the heat exchanger of high efficiency appliances"
"How far from any open flame or fuel burning appliance must an oil tank be installed? -
CORRECT ANSWER 5'"
"Can cast iron fittings be used on oil tank piping? - CORRECT ANSWER No"
"When nozzles are dirty or plugged, they should be: - CORRECT ANSWER Replaced"
"Nozzles are normally cooled by: - CORRECT ANSWER The air & fuel travelling past or
through them"
"The burner air tube should be installed ________________ back fromthe inside wall of the
combustion chamber. - CORRECT ANSWER ¼""
"Nozzle after drip can be caused by: - CORRECT ANSWER Bad pump shutoff (PRV), air
in nozzle line"
"Fuel must burn completely in suspension without touching what? - CORRECT
ANSWER The crown sheet, chamber floor or walls"
"True or false, ideally combustion chambers should be designed to both heat up and cool
off quickly: - CORRECT ANSWER True"
1
, "If a chamber is too small, or the nozzle is too close to the chamber floor there will be: -
CORRECT ANSWER Impingement"
"With no insulating material between the heat exchanger and the hot flue gasses, heat
transfer to the water is - CORRECT ANSWER Better"
"Combustion tests give us the "steady state" efficiency of the unit. We test: - CORRECT
ANSWER The composition of the gasses (excess air), smoke concentration,temperature of
the gasses, draft through the unit"
"True or False, the more efficient the appliance the higher the stacktemperature will be: -
CORRECT ANSWER False"
"What is "steady state"? - CORRECT ANSWER At steady state there are no changes in
the combustion gases. The unit has thoroughly warmed-up and will maintain constant
conditions as long as the burner runs."
"Proper location of the hole in the flue pipe for combustion testing is: - CORRECT
ANSWER In the flue pipe near the appliance outlet (the breech)."
"How many strokes are necessary when performing a smoke test? - CORRECT
ANSWER 10 full strokes"
"An electrical load is a device which converts electrical energy into: - CORRECT
ANSWER Another form of energy to perform "work""
"Step-down transformers have more: - CORRECT ANSWER Primary coils than
secondary coils and reduce voltage"
"Step up transformers have more: - CORRECT ANSWER Secondary coils than primary
coils and increase voltage"
"In residential systems, high limit controls are: - CORRECT ANSWER Automatic, line
voltage, temperature or pressure activated switches, wired in series with the primary
control."
2
, "The fan & limit control on a warm air system is used: - CORRECT ANSWER To turn the
burner off at a set temperature, and turn the blower on and off at set temperatures"
"Average warm air limit settings: - CORRECT ANSWER 200°F Limit, 140°F Fan = On,
110°F Fan = Off"
"What commonly causes a burner on a warm air system to go off on high limit: -
CORRECT ANSWER Fan failure, clogged air filters, or broken blower belt"
"High limit aqua stats prevent: - CORRECT ANSWER Boiler water temperature rising to
unsafe levels"
"Low limit (operating) aqua stats prevent: - CORRECT ANSWER Boiler water
temperature dropping below a set point"
"Switching relays allow control of: - CORRECT ANSWER A line voltage load with a low
voltage control (like a thermostat)"
"When mounting a thermostat, it should be: - CORRECT ANSWER About 5' from the
floor, on an inside wall, away from heat emitters, and away from windows & outside doors"
"The end switch on a zone valve is commonly wired to: - CORRECT ANSWER T-T on
the boiler temperature control"
"Primary controls have three basic functions: - CORRECT ANSWER Respond to the
thermostat, respond to the limit control, and supervise the starting, running & stopping of
the burner"
"Intermittent Ignition is: - CORRECT ANSWER Spark on whenever burner runs"
"Interrupted Ignition is: - CORRECT ANSWER Spark remains on for a short time at the
beginning of each cycle, then isturned off once flame is established"
"When the light intensity on the cad cell increases (gets brighter) the resistance (OHMS): -
CORRECT ANSWER decreases"
"Before pressing the reset on a primary control: - CORRECT ANSWER Check for oil in
the chamber"
3