B. Authority having jurisdiction - correct answer An existing system that is not in strict compliance with the provisions of this code shall be permitted to be continued in a use as long as the __________ has determined that such use does not constitute a distinct hazard to life. A. Architect B. Authority having jurisdiction C. Engineer D. Nursing B. Designated storage area - correct answer Indoor locations for oxygen, nitrous oxide, and mixtures of these gases shall not communicate with any of the following except__________ A. Areas with open flames B. Designated storage area C. Engines D. Kitchens D. Visual pressure indicator - correct answer An auxiliary source connection shall consist of all the following except A. Removable plug or cap B. Tree C. Valve D. Visual pressure indicator A. Each building served - correct answer When multiple buildings are served from a single cryogenic liquid oxygen source, it is required to place the emergency oxygen supply connection in- A. Each building served B. The building closest to the source C. The largest building served D. The main building only B. 3 - correct answer The minimum clearance around the EOSC for a temporary source of supply is ____________ ft. A. 2 B. 3

Show more Read less
Institution
Medical Gas Installer 6010
Course
Medical gas installer 6010









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Medical gas installer 6010
Course
Medical gas installer 6010

Document information

Uploaded on
November 6, 2025
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Medical Gas Certification pre-test
B. Authority having jurisdiction - ✔✔ correct answer An existing system that is not in strict
compliance with the provisions of this code shall be permitted to be continued in a use as long as the
__________ has determined that such use does not constitute a distinct hazard to life.

A. Architect

B. Authority having jurisdiction

C. Engineer

D. Nursing



B. Designated storage area - ✔✔ correct answer Indoor locations for oxygen, nitrous oxide, and
mixtures of these gases shall not communicate with any of the following except__________

A. Areas with open flames

B. Designated storage area

C. Engines

D. Kitchens



D. Visual pressure indicator - ✔✔ correct answer An auxiliary source connection shall consist of all
the following except

A. Removable plug or cap

B. Tree

C. Valve

D. Visual pressure indicator



A. Each building served - ✔✔ correct answer When multiple buildings are served from a single
cryogenic liquid oxygen source, it is required to place the emergency oxygen supply connection in-

A. Each building served

B. The building closest to the source

C. The largest building served

D. The main building only



B. 3 - ✔✔ correct answer The minimum clearance around the EOSC for a temporary source of supply
is ____________ ft.

A. 2

B. 3

, Medical Gas Certification pre-test
C. 5

D. 6



A. Except be filtered to 0.01 microns - ✔✔ correct answer The quality medical air shall comply with
all of the following standards except

A. Be filtered to 0.01 microns

B. Have lesson than 25 ppm gaseous hydrocarbons

C. Have no detectable liquid hydrocarbons

D. Meet the requirement of medical air USP



B. Human respiratory applications - ✔✔ correct answer Medical air sources shall only be use for
_____



A. Air operating devices

B. Human respiratory applications

C. Instrument air

D. WAGD



B. 1 - ✔✔ correct answer Medical air filters shall be sized for 100% of the system peak calculated
demand and be rated for a minimum of 98% efficiency at ______ micron greater.

A. .01

B. 1

C. 5

D. 10



A. At least duplexed - ✔✔ correct answer In a medical air supply system dryers, filters, and regulators
shall be.

A. At least duplexed

B. At least simplexed

C. Downstream of the source valve

D. Upstream of the aftercoolers

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
brittton phoenix
View profile
Follow You need to be logged in order to follow users or courses
Sold
150
Member since
2 year
Number of followers
95
Documents
5175
Last sold
2 weeks ago
BRITTTON PRESENTS YOU WITH QUALITY EXAM,TESTBANKS AND ASSIGNMENTS

providing high quality grades is my all time priority, welcome to the world of super grades All The Best!!!!

3.3

19 reviews

5
6
4
3
3
5
2
1
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions