Competent person - ANSWER -A person who is capable of identifying existing
and predictable hazards in the surroundings or working conditions which are
unsanitary, hazardous, or dangerous to employees, and who has authorization to
take prompt corrective measures to eliminate them.
Lead - ANSWER -metallic lead, all organic lead compounds, and organic lead
soaps.
PEL - ANSWER -50 in a 8 hr day
Methods of initial determination - ANSWER -Historical or Action
When and who to monitor - ANSWER -Best practice within 24 hr of start of each
job
Pull data from highest potential exposure shift
Monitor full day (7 hrs OSHA)
Monitor for other hazardous metals in coatings if appropriate
Power tool cleaning WITH dust collection - ANSWER -1/2 face
Power tool cleaning WITHOUT dust collection - ANSWER -Full face
Notify workers of results - ANSWER -5 days
How many people should be monitored? - ANSWER -25% of the people (OSHA)
Results from pre monitoring - ANSWER -<30 no monitoring
30-50 every 6 months
>50 3 months
OSHA way of dealing with hazards - ANSWER -ELIMINATION
Washing Station - ANSWER -Running water
Blood monitoring - ANSWER -New people - Every 2 months for 6
, Then 6 months afterwards
Back to back levels above 50 - ANSWER -Removal from the job and must report
on OSHA 300 Log
If above 50, to be able to return back to work - ANSWER -2 tests back to back
below 40 (2 weeks apart)
Hazard Communication - ANSWER -Notify the dangers, Warning sign, Labels
and pictograms, and SDS and PDS
Training frequency - ANSWER -Repeated annually, or any other change in
operations
Access to materials - ANSWER -Everyone must be able to read and understand
and a copy of OSHA 29 CFR 1926.62
Lead signs color - ANSWER -Black, white, and red
Record Keeping - ANSWER -30 years or more
What to do when OSHA comes on site... - ANSWER -Review EVERYTHING.
PPE, Documents, hygiene programs, and cleanness
Arsenic Standards - ANSWER -Trigger level - 30 days above 5
Arsenic Recordkeeping - ANSWER -40 years OR duration of employment + 20
years
What is the PEL and Action level of lead standard? - ANSWER -30 and 50
When must you notify your workers the results of lead results - ANSWER -5 days
What inspection does a competent person have to preform - ANSWER -
Ventilation inspection, verification of site cleanliness, and regulated area is defined
Which two standards require PPE and hygiene facilities when present or likely to
be present? - ANSWER -Inorganic Arsenic and Hexavalent Chromium