2025/2026

ANESTHESIA MACHINE QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE Identify the components of the low pressure system in the anesthesia machine (select 2) a. cylinder pressure regulator b. Oxygen flush valve c. Flowmeter tubes d. common gas outlet - Answers c. Flowmeter tubes d. common gas outlet High pressure: cylinder pressure regulator intermediate pressure: oxygen flush valve Match the following examples of anesthesia machine/circuit components to their proper location in the SPDD model 1) Disposal a) Cylinder 2) Delivery b) Vaporizer 3) Supply c) Circle system 4) Processing d) Scavenger - Answers Disposal= scavenger Delivery= circle system Supply= cylinder Processing= vaporizer The PISS system is used to: a. prevent the use of wrong gas hose b. diagram the pathway of gas through the anesthesia machine c. filter & exchange air in the OR d. prevent the use of the wrong gas cylinder - Answers d. prevent the use of the wrong gas cylinder The pin index safety system (PISS) prevents wrong cylinder from being attached to anesthesia machine. The diameter index safety system (DISS) prevents the wrong gas hose from being attached to the anesthesia machine SPDD model describes the pathway of gas through the anesthesia machine Filtering & exchanging air in the OR is not a function of the anesthesia machine The bourdon pressure gauge on an oxygen cylinder reads 500psi. If the flow rate is 2L/min, how long will this cylinder provider O2 o the patient. (enter minutes & round to nearest whole number) - Answers 83-87 (660L/1900psi)=conversion factor 500 x conversion factor / 2L per min= 86.4 min Identify the best practices for handling gas cylinders (select 2) a. removing the plastic over on the port when installing the cylinder b. placing 2 washers between the cylinder & the hanger yoke c. oiling cylinder valves every 6 months d. laying the cylinder on its side when changing the cylinder on the anesthesia machine - Answers a. removing the plastic over on the port when installing the cylinder d. laying the cylinder on its side when changing the cylinder on the anesthesia machine Under normal circumstances, gas cylinders must be stored in upright position and secured. When changing the cylinder on the anesthesia machine, it is appropriate to temporarily place the old cylinder on its side until it can be moved to its appropriate storage receptacle. you should remove the plastic over from the port before installing the cylinder. failure to do so may obstruct gas flow when the cylinder is turned on oiling the cylinder valve increases risk of fire by combining O2 & N2O with oil. If there is a leak after you install a cylinder, do not be tempted to place more than one washer b/t the cylinder & the hanger yoke assembly. This may bypass the PISS & allow the wrong

Show more Read less
Institution
ANESTHESIA MACHINE
Course
ANESTHESIA MACHINE










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ANESTHESIA MACHINE
Course
ANESTHESIA MACHINE

Document information

Uploaded on
October 30, 2025
Number of pages
19
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ANESTHESIA MACHINE QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2025-2026

Identify the components of the low pressure system in the anesthesia machine (select 2)



a. cylinder pressure regulator

b. Oxygen flush valve

c. Flowmeter tubes

d. common gas outlet - Answers c. Flowmeter tubes

d. common gas outlet



High pressure: cylinder pressure regulator

intermediate pressure: oxygen flush valve

Match the following examples of anesthesia machine/circuit components to their proper
location in the SPDD model



1) Disposal a) Cylinder

2) Delivery b) Vaporizer

3) Supply c) Circle system

4) Processing d) Scavenger - Answers Disposal= scavenger

Delivery= circle system

Supply= cylinder

Processing= vaporizer

The PISS system is used to:



a. prevent the use of wrong gas hose

b. diagram the pathway of gas through the anesthesia machine

c. filter & exchange air in the OR

,d. prevent the use of the wrong gas cylinder - Answers d. prevent the use of the wrong gas
cylinder



The pin index safety system (PISS) prevents wrong cylinder from being attached to anesthesia
machine.



The diameter index safety system (DISS) prevents the wrong gas hose from being attached to
the anesthesia machine



SPDD model describes the pathway of gas through the anesthesia machine



Filtering & exchanging air in the OR is not a function of the anesthesia machine

The bourdon pressure gauge on an oxygen cylinder reads 500psi. If the flow rate is 2L/min, how
long will this cylinder provider O2 o the patient. (enter minutes & round to nearest whole number)
- Answers 83-87



(660L/1900psi)=conversion factor

500 x conversion factor / 2L per min= 86.4 min

Identify the best practices for handling gas cylinders (select 2)



a. removing the plastic over on the port when installing the cylinder

b. placing 2 washers between the cylinder & the hanger yoke

c. oiling cylinder valves every 6 months

d. laying the cylinder on its side when changing the cylinder on the anesthesia machine -
Answers a. removing the plastic over on the port when installing the cylinder

d. laying the cylinder on its side when changing the cylinder on the anesthesia machine



Under normal circumstances, gas cylinders must be stored in upright position and secured.

, When changing the cylinder on the anesthesia machine, it is appropriate to temporarily place the
old cylinder on its side until it can be moved to its appropriate storage receptacle.



you should remove the plastic over from the port before installing the cylinder. failure to do so
may obstruct gas flow when the cylinder is turned on



oiling the cylinder valve increases risk of fire by combining O2 & N2O with oil.



If there is a leak after you install a cylinder, do not be tempted to place more than one washer
b/t the cylinder & the hanger yoke assembly. This may bypass the PISS & allow the wrong
cylinder to be matched up with the wrong hander yoke assembly

The oxygen pressure failure device activates when the: (select 2)



a. FiO2 in the inspiratory limb is less than 21%

b. oxygen pressure in the supply line is less than 20 psi

c. oxygen pipeline crossover with N2O

d. oxygen tank is exhausted - Answers b. oxygen pressure in the supply line is less than 20 psi

d. oxygen tank is exhausted



The oxygen pressure failure device monitors O2 pressure (not concentration). It activates when
O2 pressure in the intermediate pressure system falls below 20 psi. By contrast, the O2 analyzer
monitors O2 [ ] in the low pressure system. It alarms when the FiO2 falls below 21%



If pipeline pressure fails, the auxiliary O2 tank is open, the O2 pressure failure device won't
activate until O2 pressure from tank is < 20 psi. This explains why you don't want to leave O2
cylinder open if not using it.

Hypoxia prevention safety device on the anesthesia machine will:



a. prevent a hypoxic mixture if a third gas is used

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
joshuawesonga22 Liberty University
View profile
Follow You need to be logged in order to follow users or courses
Sold
36
Member since
8 months
Number of followers
1
Documents
11104
Last sold
22 hours ago
Tutor Wes

Hi there! I'm Tutor Wes, a dedicated tutor with a passion for sharing knowledge and helping others succeed academically. All my notes are carefully organized, detailed, and easy to understand. Whether you're preparing for exams, catching up on lectures, or looking for clear summaries, you'll find useful study materials here. Let’s succeed together!

3.3

3 reviews

5
1
4
0
3
1
2
1
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions