Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 11 pages
Exam (elaborations)

ASSE 15000 Practice Test 3 EXAM Questions AND Correct Answers

Document preview thumbnail
Preview 2 out of 11 pages

ASSE 15000 Practice Test 3 EXAM Questions AND Correct Answers

Content preview

ASSE 15000 Practice Test 3 EXAM Questions AND Correct Answers
A ___ shall be installed where an electric variable speed pressure limiting controller is installed and the
maximum total discharge head, adjusted for elevation, exceeds the pressure of the system components.
- ✔✔pressure relief valve



A _____ fitting is used when the pipe size is different than the pump suction side. - ✔✔eccentric tapered
reducer or increaser



A _____ standpipe is used in a high rise building exposed to freezing temperatures. - ✔✔class I
automatic dry



A "very tall building" is defined as a ____ where the fire protection water demand ___ capacity of the
fire department. - ✔✔high-rise building / exceeds the pumping



A break tank is_____ - ✔✔a pressure reducing tank



A class I standpipe system shall provide ___ hose connections to supply water for use by fire
departments and those trained in handling heavy fire streams. - ✔✔2-1/2"



A diesel fuel storage tank is required to always be a minimum of __ full. - ✔✔2/3



A fire pump controller acceptance test shall include a minimum of _____ operations. - ✔✔6 automatic
and 6 manual



A fire pump controller shall be in a fully functional state within ___ seconds of AC power available. -
✔✔10



A fire pump water supply must be ___. - ✔✔Adequate and dependable



A flow test of a well shall be continuous for a period of at least a __ hours at 150 percent of the rated
capacity of the pump with 15-minute-interval readings over the period of the test. - ✔✔8

, A main drain shall be provided on the standpipe _____ side of the conrol valve. - ✔✔system



A standpipe with a 2 1/2" pressure regulating valve shall be equipped with a ___ minimum drain riser. -
✔✔3"



A sysytem that activates when only the detection system activates, but does not activate when a
sprinkler opens, is a ____ preaction system. - ✔✔single-interlock



A temporary standpipe used during construction must be at least ___ in diameter - ✔✔4 inches



A variable speed fire pump is defined as a fire pump with ___ - ✔✔variable speed pressure limiting
control or self-regulating variable speed fire pump unit



A variable speed fire pump is defined as a fire pump with a ___. - ✔✔variable speed sensing limiting
control or self -regulating variable speed fire pump unit



According to NFPA 13, the minimum distance between residential sprinklers shall be __ feet. - ✔✔8



According to NFPA 20 the minimum gauge pressure, at the pump suction flange, required with all pumps
running at 150% capacity? - ✔✔0



According to NFPA 20, a _____ refill valve shall be used for each water supply tank used for fire
protection. - ✔✔automatic



According to NFPA 20, a suction pressure regulating valve is installed according to the manufacturers
recommendations and in the piping between the _____. - ✔✔pump and discharge check valve



According to NFPA 20, screens on the suction intake of a water supply from an open source must be
inspected _____ for accumulated debris. - ✔✔periodically

Document information

Uploaded on
October 27, 2025
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ExamsCentre
3.7
(3)
Sold
13
Followers
0
Items
1709
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions