Type of sealant you should you use on a Phil-Tite Ball Float nipple: —Answer: Pipe dope
Number of open valves on the clean air separator: —Answer: One
You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or False? —Answer:
False
The type of pressure gauge is recommended to test Healy Vac —Answer: SYSA gauge
measuring 0-100 WC
On new construction, after July 1, 2004, Can you install an in-ground Spill Bucket? —Answer:
YES-When Piping is monitored and with VAC
According to Executive Order 201 - Healy P/V Valve should be torqued at —Answer: 20-50 ft-
lbs
For a fire to burn, these (3) three primary elements must exist: —Answer: Fuel, Oxygen,
Ignition Source
When working with Electrical - Lock Out Tag Out procedures are under these guidelines. —
Answer: CAL-OSHA
Organization that certifies vapor recovery systems. —Answer: CARB or ARB
According to RP 500, a level II technician may NOT inspect this part. —Answer: Replace VP
1000 Healy Pump
where hanging hardware repairs must be tracked. —Answer: GDF maintenance log
approved sealant when assembling a Phil-Tite Drop Tube. —Answer: JB-Kwik
Material direct bury OPW container sleeve shall be made of. —Answer: Stainless steel
© 2025 All rights reserved
, What P/V vent cap shall be tightened to. —Answer: 20-50 ft lbs
From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From manifold to tank - 3"
diameter vapor piping (3" ID) —Answer: Vapor piping
What is the maximum run for vapor piping? —Answer: No maximum run
How you know a nozzle spout is bad. —Answer: 'BAD O-rinqs
According to PEI RP 300, on a balance Stage II vapor recovery system nozzle, Vapors typically
flow in what direction of the coaxial hose? —Answer: The outside pathway
What is the maximum allowable number of P/V caps allowed on a UST fuel system? —Answer:
One
On a Healy Air Separator, there are four Ball Valves, the following shall be observed? —
Answer: One valve shall remain open on top
The Pressure settings for the UST Vent Cap is. —Answer: .0+- 0.5inches H2O Negative Pressure
1,0+-2.0 inches H2O Positive Pressure
Given that in a balance Stage II vapor recovery system, the nozzle is equipped with a flexible
nozzle bellows that seals around the automobile fill pipe. This is how vapors will typically flow.
—Answer: From the outside pathway of the coaxial hose
The Healy 1301 flow limiter shall be used when the flow rate exceeds this. —Answer: 10.0
GPM
Given that: The VP1000 vacuum pump motor will operate automatically when the temperature
drops. The VP1000 will automatically operate when the temperature drops below this
temperature. —Answer: 40 f (35f if 40f is not an option)
How do you verify a nozzle spout is bad and needs to be replaced? —Answer: Test the nozzle
Given that a "Classified Area" is a located where a fire and explosion hazard exists due to the
presence of fuel vapors. Because vapors are heavier than air In a Class I, Division 2 area, where