Nate Air-To-Air Heat Pump Practice Test 2 With All
Correct & 100% Verified Answers |Already Graded A+

A good evacuation of a refrigerant circuit to remove non-condensable will help ensure: ✔Correct
Answer-Higher efficiency and Capacity.

A condensing unit should be mounted on a slab that is level to allow: ✔Correct Answer-
Accumulated water to evenly run from the cabin.

Low airflow over a residential split system air conditioning evaporator can cause: ✔Correct
Answer-Liquid flood-back to the compressor.

Which of the following is the correct sequence of work: ✔Correct Answer-Attach the gauge
manifold, recover refrigerant, replace the filter core, evacuate the system, recharge the system.

As the pressure on the liquid is increased, the vaporization temperature of the liquid: ✔Correct
Answer-Increases.

An oil-separator must be mounted: ✔Correct Answer-Level.

Which of the following metering devices controls evaporator pressure: ✔Correct Answer-None of
these.

The purpose of the external equalizer on the thermostatic expansion valve is: ✔Correct Answer-To
equalize evaporator pressure drop with respect to the TEV.

The higher the MERV rating of a filter-drier, the: ✔Correct Answer-MERV does not apply to filter-
driers.

Zeolite is used with: ✔Correct Answer-Refrigerant filter driers.

Vacuum pressures are measured in: ✔Correct Answer-Microns, Millimeters or Inches of mercury.

The number 25,400 relates to: ✔Correct Answer-Microns/Inch.

A general rule of thumb for airflow: ✔Correct Answer-400 CFM/Ton.

A double suction riser is used to: ✔Correct Answer-Improve oil return as system capacity changes.

A service technician measures a return air temperature of 80 degrees and a supply air temperature
of 55 degrees. What, if anything, may be wrong with this air residential split system air conditioning
unit? ✔Correct Answer-Low airflow through evaporator.

The normal compression ratio for a typical comfort air conditioning application should be in the
range of: ✔Correct Answer-2.75 to 3.75.

All else being normal, if a system shows a high, low-side superheat with higher condenser sub-
cooling, what is the most likely problem? ✔Correct Answer-A partial refrigerant restriction.

, All else being normal, if a system shows a low, low-side super heat with a high condenser sub-
cooling, what is the likely problem? ✔Correct Answer-Refrigerant overcharge.

All else being normal, if a system shows a high, low-side superheat with low condenser sub cooling,
what is most likely the problem? ✔Correct Answer-Refrigerant undercharge.

A grille equipped with a damper control is called: ✔Correct Answer-Register.

A pressure relief valve is... ✔Correct Answer-Direct pressure acting.

A parallel compressor system in which both the crankcase oil level and refrigerant gas pressure are
equalized is a: ✔Correct Answer-Double pipe crankcase equalizer system.

In a direct expansion chiller used on air conditioning applications, the refrigerant is on what side of
the tubes? ✔Correct Answer-Inside of the tubes.

The total minimum open area for air to flow through on a supply air register is called: ✔Correct
Answer-Free area.

Which type of copper tubing has the thickest wall? ✔Correct Answer-Type K.

What is the gross weight of a refrigerant cylinder? ✔Correct Answer-The weight of the cylinder
plus the weight of the refrigerant.

What does an anemometer measure? ✔Correct Answer-Feet (time is a separate operation,
automated for your convenience).

The term induced draft most likely referes to... ✔Correct Answer-A type of cooling tower.

What fitting should be used to connect 1/4" copper tuning to a 1/4" internal pipe thread opening on
a compressor crankcase? ✔Correct Answer-Half-union.

Which compressor has the fewest moving parts? ✔Correct Answer-Scroll.

A hot liquid-line with a low to normal high side pressure is an indication of: ✔Correct Answer-An
undercharged system.

Air and water are directed counter-flow so as to: ✔Correct Answer-Gain the greatest amount of
heat transfer.

What is not a mechanical cooling system? ✔Correct Answer-Evaporative cooling.

A compressor is short cycling, which of the following would not be the cause? ✔Correct Answer-
Leaking compressor suction valve.

The position of the valve stem on the suction service valve is normally: ✔Correct Answer-Fully
back-seated.

OF the three fundamental fan laws, one states that the power varies by the ___ of the speed.
✔Correct Answer-Cube.

Document information

Uploaded on
October 24, 2025
Number of pages
6
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$8.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Studyclub
3.6
(14)
Sold
60
Followers
1
Items
12284
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions