FINAL EXAM : Sterile Processing -
2025 update COMPREHENSIVE
FREQUENTLY TESTED
QUESTIONS and verified answers
100% accurate answers already
graded A+
Why is it important to evenly distribute large instruments in a set? - ansExtra condensation
will make the set more difficult to dry
Which of the following BEST describes the overall role of the CS/SPD - ansTo provide
dependable service to enhance patient care
Which of the following government agencies regulates environmental disinfectants? -
ansOSHA
Medical-grade kraft paper CANNOT be used with which of the following sterilization
processes ? - ansLow temperature gas plasma
During cycle counts, items that have a large dollar value but are NOT used frequently are
classified as - ansA
Anatomy is the science that deals with the________ of the body parts - ansStructure
Which of the following transports molecules within the cell? - ansCytoplasm
Which of the following sets would be considered high risk for special prion processing? -
ansCraniotomy set
Which of the following organs produces bile? - ansLiver
Microorganisms are measured in - ansMicrons
With respect to rigid sterilization container testing, which term defines the sterilizer's ability
to sterilize under actual conditions? - ansMaximum load testing
What is the ideal human body temperature? - ans98.6° F
Which of the following is TRUE of capsules - ansIt is resistant to heat and chemicals
Pulmonary capillaries are found in which system? - ansRespiratory
Ethics is the practice of - ansDoing the right thing.
A microorganism that is resting and had a hard shell like outer covering is called a - ansSpore
Spongiform encephalopathy is caused by which of the following - ansPrions
Nails,tissues, and money are examples of - ansFomites
Cholera is transmitted by - ansContaminated food and water
In the FINAL step of hand washing, the fingers should be rinsed with the fingertips - ansUP
Water less hand antiseptics contain what percentage concentration of alcohol make the
MOST effective - ans60% to 95%
All of the following play a role in how bones support other body systems EXCEPT -
ansDistribution of hormones
OSHA requires that containers of potentially infectious materials be - ansLeakproof
Round or spherical bacterial are called - ansCocci
The removal of contamination from an item to the extent necessary for further processing is
called - ansCleaning
Which of the following should be cleaned daily - ansFloors and work surfaces

,FINAL EXAM : Sterile Processing -
2025 update COMPREHENSIVE
FREQUENTLY TESTED
QUESTIONS and verified answers
100% accurate answers already
graded A+
Which of the following is a TRUE statement regarding the use of personal protective
equipment (PPE) in the decontamination area - ansFailure to wear PPE can result in
disciplinary action
Before the medical device is cleaned and processed - ansThe manufacturer's instructions must
be obtained
The MINIMUM time needed for effective hand washing is - ans15 seconds
Which of the following IS NOT s consideration when selecting a detergent? - ansCost of
detergent
The relative acidity or alkalinity of a solution is referred to as its - anspH
Clostridium botulinum is harbored in (the) - ansSoil
A solution with a pH of 3 is considered - ansAcidic
A solution with a pH of 13 is considered - ansAlkaline
Which of the following are major non living reservois of infectious diseases - ansSoil and
water
Alkaline detergents are BEST for mechanical washers because of - ansExtended dry cycles
Which of the following is used to remove severe stains on stainless steel instruments -
ansOrganic acid detergent
One method of preventing biofilm formation on instruments is to - ansRinse the instruments
with distilled water and dry them out
An ultrasonic lumen cleaner is used to clean - ansLaparoscopic instruments
To reduce the potential for instrument corrosion, the multi step process is in a mechanical
washer consists of - ansAlkaline,wash,acid rinse,regular rinse
Opened but unused instrument sets should be - ansCompletely reprocessed
If too many microorganisms remain on an item after the cleaning process, the -
ansDisinfection process might not be effective
Which of the following chemicals are bactericidal and used for the cleaning inanimate
environmental surfaces and floors? - ansQuaternary ammonium compounds
What is the ceiling threshold limit value for glutaraldehyde? - ans0.05ppm
Which of the following pieces of equipment is used to regulate body temperature -
ansHypo/hyperthermia machine
Which of the following pieces of equipment is used to prevent the formation of blood clots? -
ansSequential compression device
Which series of stainless steel is used to manufacturer osteotomes? - ans400
For manual lubrication, surgical instruments should be placed in a lubricant solution and then
- ansRoom air dried
Which of the following should be cut with dissecting scissors ? - ansTissue

,FINAL EXAM : Sterile Processing -
2025 update COMPREHENSIVE
FREQUENTLY TESTED
QUESTIONS and verified answers
100% accurate answers already
graded A+
What is the purpose of a tungsten carbide insert on a needle holder? - ansTo hold the suture
needle better
When should laparoscopic instruments be reassembled for sterilization? - ansWhen
recommended by the manufacturer
Which of the following types of instruments are used to view internal organs through very
small openings? - ansEndoscopic
Instruments must NEVER be - ansEngraved
Which of the following is an example of a flexible endoscope? - ansBronchoscope
In the sterile storage area of CS/SPD, the temperature is 70° F (21°C) and the humidity is
69%. What should be done ? - ansContinue with routine activities
Anyone entering the the preparation area MUST - ansWear proper attire
Where should the chemical indicator be placed when sterilizing two large basins with smaller
basins in one set? - ansIn the top and bottom basins
If a wrapper will be used as a sterile field, how far over the edge of the table MUST it extend
? - ans6 inches
Rigid containers are a medical device and MUST have a 510(k) clearance from the - ansFDA
(food and drug administration)
The three basic shapes of microbes are round spiral and - ansRod like
In NON TABLE TOP steam sterilizers steam is generated - ansA boiler
Autoclave tape is considered which class of indicator ? - ansClass 1
The part of the steam sterilizer that produces heat inside the chamber to prevent condensation
from forming on the chamber walls is the - ansJacket
The need for frequent reprocessing can be MINIMIZED by - ansProper stock rotation
What is the coldest part of the sterilizer - ansDrain line
Gradual heating of packs occurs during which phase of the steam sterilizer cycle? -
ansConditioning
An emergency eye wash station MUST - ansPermit hands free operations
What is the MOST important thing to remember when double peel pouching ? - ansThe inner
pouch must lay flay inside the outer pouch
Which of the following BEST describes a MINIMUM exposure time, temperature , and
pressure for prevaccum steam sterilization of wrapped items? - ans4 minutes at 270°F
(132°C) and 28 to 30 pounds per square inch
What is the first step to take when an instrument needs to be sterilized for immediate use ? -
ansClean the instrument according to the manufacturer's instructions
Incoming saturated steam should be within which of the following ranges of dryness -
ans97% to 100%

, FINAL EXAM : Sterile Processing -
2025 update COMPREHENSIVE
FREQUENTLY TESTED
QUESTIONS and verified answers
100% accurate answers already
graded A+
Failure to remove all air from a package within the steam sterilizer will result in - ansPoor
steam penetration
Damage to medical/surgical supplies stored in the RECEIVING AREA can be avoided by -
ansRemoving supplies from the original shipping cartons
Steam is exhausted from the sterilizer through the - ansChamber drain line
Why MUST textile packs be placed on their sides for sterilization? - ansTo facilitate air
removal and stream penetration
The MOST unique feature of an integrating chemical indicator is its ability to - ansPerform in
parallel to a biological indicator
EO kills microorganisms by a process called - ansAlkylation
The normal concentration of hydrogen peroxide in a low temperature gas plasma sterilizer is -
ans59%
Rigid sterilization containers should be biologically tested before - ansPurchasing
In the sterile storage area, the ventilation system MUST be under - ansPositive pressure
The hourly exchange rate in the sterile storage area should be AT LEAST - ans4
Which of the following is NOT a factor affecting the dry time in a steam sterilizer ? -
ansSelected sterilization time
The optimum amount of a supply to order is called the - ansEconomical order quantity
The cochlea is part of the - ansInner ear
CS/CSP should be capable of planning for approximately what percentage of the total needs
of a unit? - ans90%
Which of the following MUST be made available to distribution personnel? - ansPolicies and
procedures for correct handling of sterile supplies
Which of the following agencies regulate EO? - ansOSHA,EPA,FDA
Another name for par level inventory is - ansFixed inventory level
Which of the following is considered a disadvantage of an exchange cart system? -
ansInventory is duplicated
Which distribution system is designed to reduce storeroom inventory ? - ansJust in time
A biological indicator should contain how many spores? - ans10-1
The drain line basket in a steam sterilizer should be cleaned - ansDaily
Effective sterilization starts with - ansThrough cleaning
Generally, incident reports should be filled - ansWithin 24 hours of incident
An exhaust hood over the EO sterilizer is an example of a(n) - ansEngineering control
Which of the following is the correct incubation temperature range for biological indicators
used in steam sterilization? - ans131°F to 140°F
Which is the largest part of the brain - ansCerebrum

Written for

Institution
Nursing associated
Course
Nursing associated

Document information

Uploaded on
October 20, 2025
Number of pages
37
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$15.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
charleswest Oxford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
77
Member since
5 year
Number of followers
63
Documents
3839
Last sold
1 week ago

3.8

13 reviews

5
6
4
2
3
3
2
0
1
2

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions