100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ICC California UST Service Technician Exam 2024/2025 | 400 Verified Questions & Answers

Rating
-
Sold
-
Pages
195
Grade
A+
Uploaded on
03-10-2025
Written in
2025/2026

Prepare for the ICC California UST Service Technician Exam 2024/2025 with 400+ accurate and well-verified questions and answers. Covers underground storage tank installation, maintenance, safety regulations, environmental compliance, and troubleshooting. Real exam content, fully updated for 2025.

Show more Read less
Institution
ICC CALIFORNIA UST SERVICE TECHNICIAN
Course
ICC CALIFORNIA UST SERVICE TECHNICIAN











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ICC CALIFORNIA UST SERVICE TECHNICIAN
Course
ICC CALIFORNIA UST SERVICE TECHNICIAN

Document information

Uploaded on
October 3, 2025
Number of pages
195
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • verified icc answers

Content preview

ICC CALIFORNIA UST SERVICE
TECHNICIAN EXAM NEWEST 2024
ACTUAL EXAM 400 QUESTIONS AND
WELL VERIFIED -ANSWER--S REAL
2025


Which agency approves a site-specific variance which allows for an alternative

method of construction or monitoring:

a.) The Regional Water Quality Board

b.) The State Water Resources Control Board

c.) The Department of Toxic Substance Control

d.) The local agency ......-ANSWER--.....a.) The Regional Water Quality Board CCR

Title 23, Sec 2681(a)



The regulations to enforce compliance of underground storage tank systems in

the state are found in?

a.) Code of Federal Regulations, 40 CFR Part 281

b.) California Code of Regulations, Title 23, Chapter 16

c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17 ......-ANSWER--.....b.)

California Code of Regulations; Title 23, Chapter 16

,By definition an "underground storage tank system" includes

a.) The tank, all connected piping and dispensers

b.) The tank, all connected piping, ancillary equipment and containment system

c.) Only the tank

d.) Only tanks totally beneath the surface of the ground ......-ANSWER--.....b.) The

tank, all connected piping, ancillary equipment and containment system



(H&SC, Sec 25281(z))



The written report submitted to the local agency after an unauthorized release is

required to include the following except:

a.) Description of actions taken to stop the release

b.) Cause of the release

c.) Method of disposal of released product

d.) Date on which the release was discovered ......-ANSWER--.....b.) Cause of the

release

CCR Title 23, Sec 2652(c)



An unauthorized release which does not escape from secondary containment

only requires a record on the operator's monitoring reports provided:

A. It did not increase the hazard of fire

B. It did not cause any deterioration of the secondary containment

,C. It was cleaned up within 8 hours of detection

D. All of the above ......-ANSWER--.....D. All of the above

H&SC, Sec 25294



The annual monitoring certification may be performed by:

A. A person possessing the appropriate contractors licenses

B. An individual trained and certified by the manufacturer of the monitoring

equipment

C. A designated UST operator

D. A person who meets the requirements of both a and b ......-ANSWER--.....D. A

person who meets the requirements of both a and b

CCR Title 23, Sec 2715(i)



When an automatic tank gauge is utilized for single-walled tank leak detection, it

shall generate a post-test hard copy data report of the following information,

except:

a.) Liquid volume

b.) Fuel depth

c.) Outside air temperature

d.) Time and date of test ......-ANSWER--.....c.) Outside air temperature

CCR Title 23, Sec 2643(b)(1)

, If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert

the transfer operator when the tank is no more than ___________ full


a.) 85%

b.) 95%

c.) 90%

d.) 80% ......-ANSWER--.....c.) 90%



An automatic tank gauge is utilized for leak detection of the ______________. a.)

Tank

b.) Tank and Piping

c.) Piping

d.) Interstitial space ......-ANSWER--.....a.) Tank

CCR Title 23, Sec 2643(b)(1)



After completion of enhanced leak detection (ELD) test, the ELD test results must

be submitted to the _________________.

a.) The local agency

b.) The SWRCB

c.) Owner of the UST system

d.) To both the SWRCB and the local agency ......-ANSWER--.....d.) To both the

SWRCB and the local agency

CCR Title 23, Sec 2644.1(a)(5)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TUTORWILLIAM NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
134
Member since
2 year
Number of followers
55
Documents
3016
Last sold
8 hours ago
TUTOR WILLIAM

4.8

73 reviews

5
65
4
4
3
1
2
1
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions