(T/F) Gasoline vapors are lighter than air ......-ANSWER--.....False: Gas vapors are
3-4 times HEAVIER than air
Overfill Protection notifies the operator when tank is at what level capacity? ......-
ANSWER--.....If equipped it will notify audibly and visually when the tank reaches
90% Capacity.
Cathodic protection systems must be inspected by a certified cathodic protection
tester within______ months of installation ......-ANSWER--.....6 months
Annual Monitor Certification records must be maintained on site for a period
of________ years ......-ANSWER--.....3 years
The minimum monetary punishment for any person who falsifies monitor records
,is? ......-ANSWER--.....$5,000
The quickest route for exposure to toxic substance is? ......-ANSWER--
.....Inhalation
For temporary tank closure you still need to monitor the tank but you don't need
an engineering report. Is this a true statement? ......-ANSWER--.....Yes
Asphyxiation is most likely to occur in low lying areas where heavier-than-air-
airvapors accumulate. Asphyxiation can be caused by: ......-ANSWER--.....An
Oxygen depleted environment
Where are ATG probes installed? ......-ANSWER--.....Through an opening in the
top of the tank.
What is the minimum fine for disabling a monitoring system? ......-ANSWER--
.....$5,000
, (T/F) when performing secondary containment testing the spill buckets get tested
as well. ......-ANSWER--.....False: Spill buckets get tested during the annual
monitor certification.
Who must the annual monitor certification test results be sent to and when must
they be notified prior to testing and after testing? ......-ANSWER--.....Local agency
must be notified prior 48 hours prior and results must be submitted within 30
days of testing
(T/F) Stage II vapor recovery is a system for exchanging gasoline vapors in a
vehicle fuel tank and product in a storage tank so that vapor omissions to the
environment during refueling are greatly reduced. ......-ANSWER--.....True:
because Stage I vapor recovery is from fuel delivery truck to storage tank
__________must report an un-authorized release within _________ hours to the
local agency ......-ANSWER--.....The owner or operator
24 hours
2025, ACTUAL EXAM QUESTIONS AND CORRECT
DETAILED -ANSWER--S |ALREADY GRADED A
REAL EXAM
(T/F) Gasoline vapors are lighter than air ......-ANSWER--.....False: Gas vapors are
3-4 times HEAVIER than air
Overfill Protection notifies the operator when tank is at what level capacity? ......-
ANSWER--.....If equipped it will notify audibly and visually when the tank reaches
90% Capacity.
Cathodic protection systems must be inspected by a certified cathodic protection
tester within______ months of installation ......-ANSWER--.....6 months
Annual Monitor Certification records must be maintained on site for a period
of________ years ......-ANSWER--.....3 years
The minimum monetary punishment for any person who falsifies monitor records
,is? ......-ANSWER--.....$5,000
The quickest route for exposure to toxic substance is? ......-ANSWER--
.....Inhalation
For temporary tank closure you still need to monitor the tank but you don't need
an engineering report. Is this a true statement? ......-ANSWER--.....Yes
Asphyxiation is most likely to occur in low lying areas where heavier-than-air-
airvapors accumulate. Asphyxiation can be caused by: ......-ANSWER--.....An
Oxygen depleted environment
Where are ATG probes installed? ......-ANSWER--.....Through an opening in the
top of the tank.
What is the minimum fine for disabling a monitoring system? ......-ANSWER--
.....$5,000
, (T/F) when performing secondary containment testing the spill buckets get tested
as well. ......-ANSWER--.....False: Spill buckets get tested during the annual
monitor certification.
Who must the annual monitor certification test results be sent to and when must
they be notified prior to testing and after testing? ......-ANSWER--.....Local agency
must be notified prior 48 hours prior and results must be submitted within 30
days of testing
(T/F) Stage II vapor recovery is a system for exchanging gasoline vapors in a
vehicle fuel tank and product in a storage tank so that vapor omissions to the
environment during refueling are greatly reduced. ......-ANSWER--.....True:
because Stage I vapor recovery is from fuel delivery truck to storage tank
__________must report an un-authorized release within _________ hours to the
local agency ......-ANSWER--.....The owner or operator
24 hours