NICET FA LEVEL 1 EXAM QUESTIONS WITH CORRECT ANSWERS LATEST

Institution
NICET
Course
NICET

Content preview

NICET FA LEVEL 1 EXAM QUESTIONS WITH
CORRECT ANSWERS

If more than one electrode is used, each electrode of the grounding system must not
be less than_______from any other electrode of another grounding system.
A. 2 feet
B. 4 feet
C. 6 feet
D. 10 feet - ANSWER-"
"C. 6 feet Hint: NFPA 70 - Article 250.53 (B) - KEY: electrodes, grounding sub system
installation

" "1. 69. Question

NFPA 72 covers which of the following for fire alarm systems? (Choose all that apply)
A. Application
B. Installation
C. Location
D. AHJ requirements
E. Performance
F. Inspection
G. Testing and Maintenance
H. Methods by which these requirements are to be achieved - ANSWER-"
"A. Application
B. Installation
C. Location
E. Performance
F. Inspection
G. Testing and Maintenance
Hint: NFPA 72 - 1.1.1 - KEY: scope of code

" "1. 70. Question

A plate type grounding electrode must be at least_______below the surface of the
earth.
A. 24""
B. 30""
C. 36""
D. 48"" - ANSWER-"
"B. 30"" Hint: NFPA 70 - Article 250.53 (H) - KEY: plate electrodes

" "1. 72. Question

,Which of the following is true for automatic drift compensation of detectors?
A. The FACP must identify the affected detector when the compensation limit is
surpassed by the detector.
B. The affected detector must show the limit has been reached at the detector.
C. This feature is only allowed for household systems.
D. A & B - ANSWER-"
"A. The FACP must identify the affected detector when the compensation limit is
surpassed by the detector. Hint: NFPA 72 - 23.8.5.4.2 - KEY: automatic drift
compensation

" "1. 73. Question

Which of the following require re-acceptance testing to be performed?
A. Smoke detectors that have been added or removed.
B. Changes to system wiring.
C. Changes to system hardware.
D. Both A and C
E. A, B, and C - ANSWER-"
"E. A, B, and C Hint: NFPA 72 - 14.4.2.1 - 14.4.2.4 - KEY: testing sub system
acceptance sub re-acceptance testing

" "1. 74. Question

Which of the following is an acceptable source for primary power of a fire alarm
system?
A. An engine driven generator or equivalent that is un-monitored.
B. An engine driven generator where a person specifically trained in its operation is
on duty at all times.
C. An engine driven generator arranged for co-generation with commercial light and
power that is un-monitored.
D. A dedicated commercial light or power branch circuit.
E. All of the above.
F. Both B and D - ANSWER-"
"B. An engine driven generator where a person specifically trained in its operation is
on duty at all times. Hint: NFPA 72 - 10.6.5.1.1 (2) - KEY: engine-driven generators

" "1. 75. Question

Testing of all circuits extending from central station must be completed at least once
every_______.
A. 12 Hours
B. 24 Hours
C. 48 Hours
D. 72 Hours - ANSWER-"
"B. 24 Hours Hint: NFPA 72 - 14.4.7 - KEY: central station service alarm systems sub
testing and maintenance

," "1. 4. Question

In both exposed and concealed areas, where a cable is installed through bored holes
in the joists, rafters, or wood members holes must be drilled so that the edge of the
hole is no closer than____from the nearest edge.
A. 5/8""
B. 1-1/4""
C. 2""
D. 1-3/4"" - ANSWER-"
"B. 1-1/4"" Hint: NFPA 70 - Article 300.4 (A)(1) - KEY: bored holes through joists

" "1. 7. Question

What term best describes the following phrase on or attached to the surface or
behind access panels that are meant to allow access.
A. exposed
B. uncover
C. accessible
D. concealed - ANSWER-"
"A. exposed Hint: NFPA 70 - Article 100 - KEY: exposed

" "1. 24. Question

What is the maximum height AFF for a publicly accessible wall-mounted fire
telephone appliance?
A. 48 inches
B. 50 inches
C. 62 inches
D. 66 inches - ANSWER-"
"A. 48 inches Hint: NFPA 72 - 24.8.18 - KEY: telephone sub textual appliances

" "1. 33. Question

What is the maximum number of size 12 AWG conductors permitted in a 4 inch x 1-
1/4 inch octagon metal junction box?
A. 2
B. 4
C. 5
D. 6 - ANSWER-"
"C. 5 Hint: NFPA 70 - Table 314.16(A) - KEY: boxes sub conductors, number in a box

" "1. 39. Question

What is the minimum allowable AWG for a class 3 conductor?
A. 16 AWG
B. 18 AWG
C. 20 AWG

, D. 22 AWG - ANSWER-"
"B. 18 AWG Hint: NFPA 70 - 725.127 - KEY: remote control, signaling, and power
limited circuits sub class 2 and class 3 circuits sub listing

" "1. 66. Question

Equipment must be engineered and tested to operate properly at_______of its
nameplate voltage.
A. 85%
B. 75%
C. 80%
D. 50% - ANSWER-"
"A. 85% Hint: NFPA 72 - 10.3.5 (1)* - voltage sub variation of
*A.10.3.5 (1) The requirement of 10.3.5 does not preclude transfer to secondary
supply at less than 85% of nominal primary voltage, provided the requirements of
10.6.7 are met.

" "1. 79. Question

Aerial coax cables must have a minimum separation distance of_______from electric
power conductors.
A. 6""
B. 4""
C. 2""
D. 12"" - ANSWER-"
"B. 4"" Hint: Article 820.44(F)(1) - KEY: aerial cables

" "1. 23. Question

When mounting heat detectors on the ceiling they must be located no less
than____inches from the sidewall?
A. 4
B. 6
C. 12
D. 36 - ANSWER-"
"A. 4 Hint: NFPA 72 - 17.6.3.1.3.1 - KEY: spot-type detectors sub heat sensing sub
location

" "1. 32. Question

What is the maximum rated output allowed for a Class 1 power-limited circuit
A. Not more than 30V and 1000 volt-amperes.
B. Not more than 30V and 100 volt-amperes.
C. Not more than 300V and 1000 volt-amperes.
D. Not more than 300V and 100 volt-amperes. - ANSWER-"

Written for

Institution
NICET
Course
NICET

Document information

Uploaded on
October 1, 2025
Number of pages
62
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
Fire Alarms Systems Nicet Level 1 Certification Exam Questions and Answers
-
25 2025
$ 178.65 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorExpert West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
552
Member since
3 year
Number of followers
313
Documents
9810
Last sold
1 day ago
TOP GRADES

Expertise in Nursing, Biochemistry, Mathematics, Psychology, Biology, History etc. My Work contains the latest, updated Exam Solutions, Study Guides.100% verified & Guarantee Top Grades Attained.

3.7

75 reviews

5
34
4
13
3
13
2
3
1
12

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions