EEG BOARD PREP EXAM (2 LATEST VERSIONS) LATEST 2025/2026 ACTUAL
EXAM WITH COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS
(100% VERIFIED ANSWERS) |ALREADY GRADED A+| ||PROFESSOR VERIFIED||
||BRANDNEW!!!||
Which of the following is most closely related to the measurement
of voltage in relation to current and resistance? - answer-***ohms
law
Paley-winer theorem
Nyquist theory
Coulombs law
Avoid the use of this in eeg because it may increase the
capacitive current to a potentially dangerous amount - answer-
extension cord
What type of electricity provides a steady source of current
flowing in one direction only? - answer-direct current
Life threatening current could pass through a pt if: - answer-
ground is not intact
,2|Page
Focal or unilateral suppression and slowing - answer-subdural
hemmorhage
Which of the following may be indicated by the prescence of
blood in the cerebrospinal fluid? - answer-***subarachnoid
hemmorhage
Extradural hemorrhage
Subdural hemmorhage
Localized hemmorhage w/ no comm w/ ventricles
According to osha when must electroneurodiagnotic equipment
be checked for leakage current, ground, resistance and electrical
safety? - answer-semiannually
Reduction of heathcare associated infections is addressed by -
answer-national patient safety goals
Sds - answer-safety data sheet
,3|Page
Which of the following is a violation of abrets code of ethics? -
answer-not striving to keep current in technology
According to abret code of ethics a credentialed technololgist
should report to abret if: - answer-they have been convicted of a
felony related to their work in neurodiagnostic
Which of the following is grounds for disciplinary action under
abrets code of ethics? - answer-being foundto have been
ineligible to rakw credentialing exam even after a credential has
been earned
Which of the following is a standard conduct for credentialed
technologist - answer-abret code of ethics
A single attenuated channel of ee may be a result of - answer-
interelectrode spacing too close
Balanced electrode impedances are important to - answer-lessen
60 hz interference
, 4|Page
Exteremly low voltage due to phase cancellation may be a result
of - answer-salt bridge
Short interelectrode distance between electrodes will cause which
of the following changes to eeg waveforms - answer-decrease
amplitude
Which of the following measures the opposition to current flow
when a known voltage is applied? - answer-impedance meter
Which of the following occurs with unbalanced electrode
impedance of greater than 20 kohms? - answer-increase in 60 hz
activity
Eeg is most useful in - answer-encephalopathy
Balanced impedances allows you to - answer-maximize common
mode rejection