Refrigeration Exam Updated Questions and Answers (2025/2026) (Verified Answers) In a dry type - direct expansion - evaporator, liquid refrigerant must boil away as close to the end of the coil as possible in order to: - Answer- Operate at high-efficiency The difference between the temperature of the temperature of the refrigerant boiling in the evaporator and the temperature at the evaporator outlet is known as the: - Answer- Evaporator superheat An expansion device that is stuck open will cause - Answer- A flooded evaporator When measuring evaporator superheat on a commercial system that has a long suction line, the pressure reading should be taken at the: - Answer- Compressor inlet Superheat measurements are best taken: - Answer- With the system operating at design conditions A technician checking the superheat on a multi circuit evaporator and finds one of the circuits bas a superheat that is higher than the others, this could be caused by: - Answer- A blocked distributor YXV with an eternal equalizer is used on: - Answer- Evaporator with high pressure drop A dry type evaporator operates most efficiently with the superheat setting approximately: - Answer- 8F & 12F An evaporator used to chill liquids is operating within normal superheat setting, but the system is not cooling the product properly. What is the cause? - Answer- Overcharge of refrigerant What time interval is required between each superheat adjustment? - Answer- 10 - 15 minutes A low temperature evaporator used for cooling space or product refrigeration must what? - Answer- Must be defrosted periodically Some special applications use a flooded evaporator (full of refrigerant) in order to maintain the proper level of liquid refrigerant, a ______ type device is used. - Answer- Low side float A properly functioning condenser will first - - Answer- De-superheat, then sub-cool The effect of an inefficient water cooled condenser will - Answer- Act the same as an air cooled condenser The refrigerant condensing temperature in a water cooled condenser is normally about ____ higher than the leaving water. - Answer- 10F The refrigerant and an air cooled condenser will normally contend at approximately ____ higher temperature than the air passing over it. - Answer- 30F Workable head pressure during periods of low ambient temperature can be achieved using? - Answer- Fan cycle control Cooling towers that pass air over water to remove system heat are limited in capacity by: - Answer- Outside air wet bulb temperature Parallel compressors often referred to as a rack system may use: - Answer- A common suction, but not a common discharge header Major difference between a cooling tower and an evaporator condenser is: - Answer- The refrigerant is indirectly cooled in the cooling tower Multiple compressors provide: - Answer- Capacity control A dirty evaporator and subsequent low evaporator pressures will cause: - Answer- Low compression rates The thermostatic expansion valve (TEV) maintains a constant ____ in the evaporator. - Answer- Superheat What type of ice is made with commercial ice maker that uses a gear motor and auger? - Answer- Shaved ice Some capillary tube systems take advantage of heat exchange by soldering the capillary tube to the suction line. In order to obtain the correct superheat reading, it must be taken: - Answer- After the capillary tube suction line heat exchanger A _____ is usually required for ultra low temperature applications. - Answer- Cascade system A hot gas defrost cycle can be initiated by a: - Answer- Timer

Content preview

Refrigeration Exam Updated
Questions and Answers (2025/2026)
(Verified Answers)
In a dry type - direct expansion - evaporator, liquid refrigerant must boil away as close
to the end of the coil as possible in order to: - Answer- Operate at high-efficiency

The difference between the temperature of the temperature of the refrigerant boiling in
the evaporator and the temperature at the evaporator outlet is known as the: - Answer-
Evaporator superheat

An expansion device that is stuck open will cause - Answer- A flooded evaporator

When measuring evaporator superheat on a commercial system that has a long suction
line, the pressure reading should be taken at the: - Answer- Compressor inlet

Superheat measurements are best taken: - Answer- With the system operating at
design conditions

A technician checking the superheat on a multi circuit evaporator and finds one of the
circuits bas a superheat that is higher than the others, this could be caused by: -
Answer- A blocked distributor

YXV with an eternal equalizer is used on: - Answer- Evaporator with high pressure drop

A dry type evaporator operates most efficiently with the superheat setting
approximately: - Answer- 8F & 12F

An evaporator used to chill liquids is operating within normal superheat setting, but the
system is not cooling the product properly. What is the cause? - Answer- Overcharge of
refrigerant

What time interval is required between each superheat adjustment? - Answer- 10 - 15
minutes

A low temperature evaporator used for cooling space or product refrigeration must
what? - Answer- Must be defrosted periodically

Some special applications use a flooded evaporator (full of refrigerant) in order to
maintain the proper level of liquid refrigerant, a ______ type device is used. - Answer-
Low side float

A properly functioning condenser will first - - Answer- De-superheat, then sub-cool

, The effect of an inefficient water cooled condenser will - Answer- Act the same as an air
cooled condenser

The refrigerant condensing temperature in a water cooled condenser is normally about
____ higher than the leaving water. - Answer- 10F

The refrigerant and an air cooled condenser will normally contend at approximately
____ higher temperature than the air passing over it. - Answer- 30F

Workable head pressure during periods of low ambient temperature can be achieved
using? - Answer- Fan cycle control

Cooling towers that pass air over water to remove system heat are limited in capacity
by: - Answer- Outside air wet bulb temperature

Parallel compressors often referred to as a rack system may use: - Answer- A common
suction, but not a common discharge header

Major difference between a cooling tower and an evaporator condenser is: - Answer-
The refrigerant is indirectly cooled in the cooling tower

Multiple compressors provide: - Answer- Capacity control

A dirty evaporator and subsequent low evaporator pressures will cause: - Answer- Low
compression rates

The thermostatic expansion valve (TEV) maintains a constant ____ in the evaporator. -
Answer- Superheat

What type of ice is made with commercial ice maker that uses a gear motor and auger?
- Answer- Shaved ice

Some capillary tube systems take advantage of heat exchange by soldering the
capillary tube to the suction line. In order to obtain the correct superheat reading, it must
be taken: - Answer- After the capillary tube suction line heat exchanger

A _____ is usually required for ultra low temperature applications. - Answer- Cascade
system

A hot gas defrost cycle can be initiated by a: - Answer- Timer

When the defrost cycle is terminated, the evaporator fans will: - Answer- Delay coming
on

Document information

Uploaded on
September 24, 2025
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuviaascorers
3.7
(67)
Sold
376
Followers
185
Items
11057
Last sold
3 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions