NYC RMO EXAM, CHAPTER 16 (Refrigeration Code) EXAM REVIEW QUESTIONSWITH CORRECT SOLUTIONS UPDATED 2025/2026 SYLLABUS ALREADY GRADED!!100% GUARANTEED PASS!!!BRAND NEW VERSION 16.1.) The maximum permissible number of pounds of group 2 refrigerant for an indirect system in a commercial building for a class T machine room is? - ANSWER No limit 16.2.) The "safety code for mechanical refrigeration" calls for ducts on one or more power driven exhaust fans, to remove gas from the refrigeration machinery room. In an R-12 plant, the inlet to such ducts shall be located? - ANSWER Near the floor next to the refrigeration equipment 16.3.) According to the NYC Refrigeration Code; when withdrawing refrigerant from a system, to what capacity shall the container used to hold the refrigerant be filled? - ANSWER 80% 16.4.) Muntz metal, zinc or magnesium cannot be used in the presence of which of the following refrigerants? - ANSWER R-40 16.5.) Which of the following correctly indicated the maximum permissible quantity of R-12 that can be used in a direct system? Refrigerant quantity is to be expressed in "lbs. per 1000 cubic feet of humanly occupied space". - ANSWER 31 16.26.) An emergency situation has developed in the mechanical equipment room. You are considering discharging the refrigerant into the sewer. You cannot do this unless? - ANSWER The Fire Department/plant supervisor? oversees the discharge (ask professor) 16. 7.) The maximum permissible quantity of refrigerant in a R-22 direct system 22 lbs. per 1000 cu. ft. of humanly occupied space. A particular R-22 system has evaporator coils serving individual stories of a building. The amount of refrigerant in the system will be determined by? - ANSWER The story having the smallest volume 16.8.) Which of the following correctly indicates the maximum permissible quantity of R-744 that can be used in a direct system? Refrigerant quantity is to be expressed in "lbs. per 1000 cubic feet of humanly occupied space". - ANSWER 11 16.9.) According to the ANSI/ASHRAE standard; when withdrawing refrigerant from a system, to what capacity shall the container used to hold the refrigerant be filled? - ANSWER 80%

Content preview

NYC RMO EXAM, CHAPTER 16
(Refrigeration Code) EXAM
REVIEW QUESTIONSWITH
CORRECT SOLUTIONS UPDATED
2025/2026 SYLLABUS ALREADY
GRADED!!100% GUARANTEED
PASS!!!<<BRAND NEW
VERSION>>
16.1.) The maximum permissible number of pounds of group 2 refrigerant for an
indirect system in a commercial building for a class T machine room is? -
ANSWER ✓ No limit

16.2.) The "safety code for mechanical refrigeration" calls for ducts on one or
more power driven exhaust fans, to remove gas from the refrigeration machinery
room. In an R-12 plant, the inlet to such ducts shall be located? - ANSWER ✓
Near the floor next to the refrigeration equipment

16.3.) According to the NYC Refrigeration Code; when withdrawing refrigerant
from a system, to what capacity shall the container used to hold the refrigerant be
filled? - ANSWER ✓ 80%

16.4.) Muntz metal, zinc or magnesium cannot be used in the presence of which of
the following refrigerants? - ANSWER ✓ R-40

16.5.) Which of the following correctly indicated the maximum permissible
quantity of R-12 that can be used in a direct system? Refrigerant quantity is to be
expressed in "lbs. per 1000 cubic feet of humanly occupied space". - ANSWER ✓
31

, 16.26.) An emergency situation has developed in the mechanical equipment room.
You are considering discharging the refrigerant into the sewer. You cannot do this
unless? - ANSWER ✓ The Fire Department/plant supervisor? oversees the
discharge (ask professor)

16. 7.) The maximum permissible quantity of refrigerant in a R-22 direct system
22 lbs. per 1000 cu. ft. of humanly occupied space. A particular R-22 system has
evaporator coils serving individual stories of a building. The amount of refrigerant
in the system will be determined by? - ANSWER ✓ The story having the smallest
volume

16.8.) Which of the following correctly indicates the maximum permissible
quantity of R-744 that can be used in a direct system? Refrigerant quantity is to be
expressed in "lbs. per 1000 cubic feet of humanly occupied space". - ANSWER ✓
11

16.9.) According to the ANSI/ASHRAE standard; when withdrawing refrigerant
from a system, to what capacity shall the container used to hold the refrigerant be
filled? - ANSWER ✓ 80%

16.10.) Standard soft anneal copper tubing used for refrigerant piping erected on
the premises shall not be used in sizes larger than? - ANSWER ✓ 7/8 of an inch

16.11.) According to the ASHRAE standard, which of the following describes
how the discharge of a pressure relief valve or fusible plug must be installed? -
ANSWER ✓ 15 feet above the ground level and not less than 20 feet from any
window, ventilation opening or exit in any building

16.12.) When a rupture member is used in parallel with a relief valve it shall
operate at which of the following pressures? - ANSWER ✓ Not to exceed 20%
above the design working pressure

16.13.) The dial of a pressure gauge installed on the high-side of a refrigeration
system shall be graduated to a minimum value of? - ANSWER ✓ 1.2 times the
design working pressure

16.14.) Which of the following could be referred to as a "pressure limiting
device"? - ANSWER ✓ High pressure cut-out

Document information

Uploaded on
September 23, 2025
Number of pages
6
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.09

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SmartscoreAaron
3.1
(7)
Sold
87
Followers
6
Items
4147
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions