Two 90-degree bends are allowed in any one conduit segment. A third bend may be acceptable under certain situations - ANSWER -Runs under 33 feet When installing racks and cabinets on an access floor, what should they be secured to? - ANSWER -The frame Min seperation from electric motors and transformers? - ANSWER -48" During which phase of the project would you determine cable labeling requirements? - ANSWER -Pre-construction Phase What type of documentation uses the original floor plans and reflects the actual installed outlet locations, cables, length, and firestopping materials? - ANSWER Record drawings Which project document is used to request clarification, supplemental information, or approval of material substitutions? - ANSWER -RFI Comparing design documents to existing conditions, verifying parking access, and determining the work hours are all examples of what you would learn during - ANSWER -A job start T1 - ANSWER -Layout of complete building per floor; serving zone boundaries, backbone distribution systems, and horizontal pathways T0 - ANSWER -Campus or site plans; exterior pathways and interbu

Show more Read less
Institution
Bicsi Technician
Course
Bicsi Technician









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Bicsi Technician
Course
Bicsi Technician

Document information

Uploaded on
September 19, 2025
Number of pages
6
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH
100% CORRECT ANSWERS
Two 90-degree bends are allowed in any one conduit segment. A third bend may
be acceptable under certain situations - ANSWER -Runs under 33 feet

When installing racks and cabinets on an access floor, what should they be
secured to? - ANSWER -The frame

Min seperation from electric motors and transformers? - ANSWER -48"

During which phase of the project would you determine cable labeling
requirements? - ANSWER -Pre-construction Phase

What type of documentation uses the original floor plans and reflects the actual
installed outlet locations, cables, length, and firestopping materials? - ANSWER
Record drawings

Which project document is used to request clarification, supplemental information,
or approval of material substitutions? - ANSWER -RFI

Comparing design documents to existing conditions, verifying parking access, and
determining the work hours are all examples of what you would learn during -
ANSWER -A job start

T1 - ANSWER -Layout of complete building per floor; serving zone boundaries,
backbone distribution systems, and horizontal pathways

T0 - ANSWER -Campus or site plans; exterior pathways and interbuilding
systems

T3 - ANSWER -Communication equipment rooms; outlet/connector locations and
cable ID

, T4 - ANSWER -Typical detail drawings; faceplate labeling; firestopping;
disability/accessibility, guidelines, and safety

T5 - ANSWER -Schedules- cabling and equipment spreadsheets for cutovers

The top of an extension ladder should extend up to the work area and _________
feet above catworlks or lofts - ANSWER -3 feet

Which document lists all the elements of a project including people and firms
involved, time frames, materials, and testing methods? - ANSWER -Scope of work

What is dispersion? - ANSWER -Widening or spreading out of the modes in a
light pulse as it progresses along the optical fiber.

Light pulses in optical fiber cables are subject to a loss in power as the light pulses
travel along the optical fiber is called - ANSWER -Attenuation
What are the two most important characteristics in transporting information over
optical fiber media? - ANSWER -Bandwidth
Attenuation
When placing cabinets on an access floor, how should the cabinets be aligned? -
ANSWER -One edge flush with the floor tile cut line

What is a telecommunications enclosure TE used for? - ANSWER -May be used
to provide a suitable option for moves, adds, and changes without compromising
infection control measures and other restrictions

What size threaded rod would you typically use in a heavy duty ladder rack
installation? - ANSWER -5/8in

A supplemental bonding network within an ER or data center consisting of a set of
conductors formed into a grid is often associated with what? - ANSWER -Access
flooring

Which type of anchor requires a hole to be drilled into the floor where the
attachment is to be made? - ANSWER -Expansion anchors
$9.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
mumbikarimi

Also available in package deal

Thumbnail
Package deal
BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH 100% CORRECT ABICSI INSTALLER 2:NSWERS
-
2 2025
$ 19.48 More info

Get to know the seller

Seller avatar
mumbikarimi Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
9 months
Number of followers
0
Documents
17
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions