Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

TEXAS PLUMBING MASTER EXAM QUESTIONS AND VERIFIED SOLUTIONS LATEST STUDY GUIDE GRADED A+.

Rating
-
Sold
-
Pages
10
Grade
A+
Uploaded on
03-09-2025
Written in
2025/2026

TEXAS PLUMBING MASTER EXAM QUESTIONS AND VERIFIED SOLUTIONS LATEST STUDY GUIDE GRADED A+. 1. air gap EXPLANATION the vertical distance between the opening of the water supply and the flood level rim of a receptacle 2. branch EXPLANATION any part of the piping system other than a main, riser or stack 3. Branch vent EXPLANATION A vent connecting one or more individual vents with a ventstack or stack vent 4. Building Drain EXPLANATION is the lowest part of the drainage system which receives waste from soil and waste pipes and connects to the building sewer 5. Building sewer EXPLANATION is drainage piping that conveys waste from the building drain to the public sewer or disposal system 6. Cleanout EXPLANATION Access opening in the drainage system used to remove obstructions 7. Combination fixture EXPLANATION Two or three compartment sink drained by a continuous waste connected to one trap 8. CombinationWaste andVentsystem EXPLANATION A horizontal wet venting system forsinks and floor drains 9. CommonVent EXPLANATION A single vent serving as the vent for two fixture drains 10. critical level EXPLANATION is an elevation mark on a vacuum breaker setting the minimum elevation the device can be installed above the flood level rim of a fixture 11. cross-connection EXPLANATION is an actual or potential tie between potable water and any source of pollution or contamination 12. Developed Length EXPLANATION A measurement of piping taken along the centerline of pipe and fittings 13. drain EXPLANATION Any pipe that conveys waste water in the drainage system 14. IndirectWaste EXPLANATION Is waste pipe that drains through an air gap to the drainage system 15. Individual vent EXPLANATION A pipe installed to vent one fixture trap.It may connect to the vent system above the fixture or terminate in the open air. 16. main EXPLANATION Is the primary or principal pipe to which branches are connected 17. potable water EXPLANATION Is waterthat issufficiently free ofimpuritiesto meet public health standards 18. Rough in EXPLANATION Parts of the plumbing system that are installed prior to the installation of fixtures. 19. Soil Pipe EXPLANATION Is drain pipe conveying sewage containing fecal matter 20. Stack Vent EXPLANATION The extension of a soil or waste stack above the highest fixture served 21. trap EXPLANATION Is a device that provides a waterseal to prevent the passage of sewer gas and allow the passage of waste 22. Trap seal EXPLANATION distance from weir to top of the dip of the trap 23. Vacuum Breaker EXPLANATION is a backflow preventer that allows air to a vacuum being pulled on a system 24. vent stack EXPLANATION A vertical vent pipe to provide circulation of air to and from the drainage system 25. Vertical pipe EXPLANATION Pipe that makes an angle of 45 degrees or more with the horizon- tal pipe 26. 6ft EXPLANATION Copper must be supported every or closer on small pipe 27. 10ft EXPLANATION Copper must be supported every on 1-1/2" or larger 28. 10 / 5 EXPLANATION Drainage pipe shall be tested with a foot head of water or air at psi 29. 32" EXPLANATION Pex 1" or smaller needs supporting every 30. Crosslink polyethylene EXPLANATION PEX stands for 31. Protected EXPLANATION Pipes shall be from breakage when passing under or through walls 32. deposited in the drainage system EXPLANATION No dangerous, flammable, poisonous, or explosive liquid shall be 33. 45 degrees EXPLANATION Trenches installed parallel to footings shall not extend below the bearing plane of the footing or wall 34. Fixtures EXPLANATION Must be set level and properly aligned with adjacent walls 35. 30 inches center t

Show more Read less

Content preview

TEXAS PLUMBING MASTER EXAM
QUESTIONS AND VERIFIED
SOLUTIONS LATEST STUDY
GUIDE GRADED A+.

, 1. air gap EXPLANATION the vertical distance between the opening of the water supply and the flood level rim

of a receptacle

2. branch EXPLANATION any part of the piping system other than a main, riser or stack
3. Branch vent EXPLANATION A vent connecting one or more individual vents with a vent stack or stack vent
4. Building Drain EXPLANATION is the lowest part of the drainage system which receives waste from soil and
waste pipes and connects to the building sewer
5. Building sewer EXPLANATION is drainage piping that conveys waste from the building drain to the public sewer
or disposal system
6. Cleanout EXPLANATION Access opening in the drainage system used to remove obstructions
7. Combination fixture EXPLANATION Two or three compartment sink drained by a continuous waste connected
to one trap
8. Combination Waste and Vent system EXPLANATION A horizontal wet venting system for sinks and floor drains
9. Common Vent EXPLANATION A single vent serving as the vent for two fixture drains
10. critical level EXPLANATION is an elevation mark on a vacuum breaker setting the minimum elevation the
device can be installed above the flood level rim of a fixture
11. cross-connection EXPLANATION is an actual or potential tie between potable water and any source of
pollution or contamination
12. Developed Length EXPLANATION A measurement of piping taken along the centerline of pipe and fittings
13. drain EXPLANATION Any pipe that conveys waste water in the drainage system
14. Indirect Waste EXPLANATION Is waste pipe that drains through an air gap to the drainage system
15. Individual vent EXPLANATION A pipe installed to vent one fixture trap. It may connect to the vent system
above the fixture or terminate in the open air.
16. main EXPLANATION Is the primary or principal pipe to which branches are connected
17. potable water EXPLANATION Is water that is sufficiently free of impurities to meet public health standards
18. Rough in EXPLANATION Parts of the plumbing system that are installed prior to the installation of fixtures.
19. Soil Pipe EXPLANATION Is drain pipe conveying sewage containing fecal matter
20. Stack Vent EXPLANATION The extension of a soil or waste stack above the highest fixture served
21. trap EXPLANATION Is a device that provides a water seal to prevent the passage of sewer gas and allow the
passage of waste
22. Trap seal EXPLANATION distance from weir to top of the dip of the trap
23. Vacuum Breaker EXPLANATION is a backflow preventer that allows air to a vacuum being pulled on a
system

Document information

Uploaded on
September 3, 2025
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
lectdenis Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
2075
Member since
4 year
Number of followers
1589
Documents
6606
Last sold
2 days ago
online tutor

FOR THE BEST ASSIGNMENTS AND HOMEWORKS ,TO HELP AND TUTORING ALL KIND OF EXAMS

3.7

299 reviews

5
133
4
48
3
49
2
19
1
50

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions