QUESTIONS WITH CORRECT ANSWERS 2025
In the absence of a complete geotechnical evaluation to determine the soil's characteristics, sandy gra
vel material shall be assumed to have a presumptive load-bearing value of psf. -
correct answer-3,000 psf
R401.4.1 Soil tests.
In the absence of a complete geotechnical evaluation to determine the soil's characteristics, sand, silty
sand, clayey sand, silty gravel, and clayey gravel material shall be assumed to have a presumptive load
-bearing value of psf. - correct answer-2,000 psf
R401.4.1 Soil tests.
In the absence of a complete geotechnical evaluation to determine the soil's characteristics, clay, sand
y, silty clay, clayey silt, silt, and sandy siltclay shall be assumed to have a presumptive load-
bearing value of psf. - correct answer-1,500 psf
R401.4.1 Soil tests.
In the absence of a complete geotechnical evaluation to determine the soil's characteristics, crystalline
bedrock shall be assumed to have a presumptive load-bearing value of psf. -
correct answer-12,000
R401.4.1 Soil tests.
In the absence of a complete geotechnical evaluation to determine the soil's characteristics, sedimenta
ry and foliated rock shall be assumed to have a presumptive load-bearing value of psf. -
correct answer-4,000
R401.4.1 Soil tests.
, Concrete used in a basement slab shall have a minimum strength of psi where a severe wea
thering potential exists. - correct answer-2,500 psi
R402.2 Concrete.
Minimum compressive strength of concrete whether or not it is exposed to weather is psi. -
correct answer-2,500 psi
R402.2 Concrete.
Where there is evidence that the groundwater table can rise to within inches of the finished
floor at the building perimeter, the grade in the under-
floor space shall be as high as the outside finished grade unless an approved drainage system is provid
ed. - correct answer-6"
R408.6 Under-floor space.
The minimum Width and Thickness for concrete footings shall not be less than inches in Wi
dth and __________ nches in depth. - correct answer-12
6
R403.1.1 Minimum size.
Footing projections shall not be less than and shall not exceed the thickness of the footing.
- correct answer-2 inches
R403.1.1 Minimum size.
All exterior footings shall be placed at least inches below the undisturbed ground surface. -
correct answer-12 inches
R403.1.4 Minimum depth.