100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE

Rating
5.0
(1)
Sold
1
Pages
104
Grade
A+
Uploaded on
27-08-2025
Written in
2025/2026

NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE

Show more Read less
Institution
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER
Course
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER

Content preview

NCLE ADVANCED CERTIFICATION


NCLE ADVANCED
CERTIFICATION EXAM STUDY
GUIDE. GRADED A+.
QUESTIONS AND 100%
VERIFIED ANSWERS. LATEST
2025/2026 UPDATE



The answer is D.

The posterior optical zone will directly affect the lens to cornea relationship of a rigid
gas permeable lens. If the posterior optical zone is steepened, it will increase the
sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the
power, which is accomplished by changing the anterior optical zone, will not affect
the sagittal depth of the lens, nor will changing its edge design. - Answer 1. The
sagittal depth of a rigid gas permeable contact lens can be altered without changing
the diameter by:

A. Changing the power
B. Changing the edge design
C. Changing the radius of curvature of the anterior optical zone
D. Changing the radius of curvature of the posterior optical zone

The answer is A.

A lens is truncated by removing a segment of the lower edge of a contact lens. This
creates a straight edge that interacts with the lower lid and aids in lens positioning.
Of the lens designs listed in the question, the only one that requires precise
positioning of its optical portions is a translating bifocal lens. - Answer 2. A truncation
is used on a rigid gas permeable contact lens to help enhance the performance of
which type of design?

A. Bifocal
B. Aphakic
C. Bitoric
D. Keratoconus

,NCLE ADVANCED CERTIFICATION
The answer is B.

,NCLE ADVANCED CERTIFICATION
A lenticular or myoflange design will decrease the mass of an aphakic lens as well
as increase the edge profile, which allows it to interact more with the upper lid and
aid in positioning of the lens. - Answer 3. The mass of an aphakic rigid gas
permeable contact lens can be reduced by making the lens design:

A. Spherical
B. Lenticular
C. Tricurve
D. Aspheric

The answer is B.

Increasing the optical zone diameter and increasing the overall lens diameter will
both tighten and steepen the relationship of the lens to the cornea. Decreasing the
optic zone diameter will serve to flatten and loosen the lens to cornea relationship.
Using a prism-ballasted lens design will not affect the lens to cornea relationship as it
relates to sagittal depth. - Answer 4. In order to tighten the fit of a rigid gas
permeable lens you can:
I. Increase the optical zone diameter
2. Decrease the optical zone diameter
3. Increase the overall lens diameter
4. Use a prism ballasted lens design

A. 3 only
B. 1&3
C. 2 only
D. 2&3

The answer is D.

A hyperflange will decrease edge thickness as well as lens awareness . Aspheric
peripheral curves change the posterior design of the lens but do not reduce edge
thickness. A higher Dk material will not change the overall lens edge thickness. A
myoflange will actually add thickness to the lens edge and is used for high plus
lenses not high minus lenses. - Answer 5. A high minus rigid gas permeable lens will
be thin centrally with relatively thick edges. To reduce the edge thickness, and
increase overall comfort, use:

A. Aspheric peripheral curves
B. A myoflange
C. A higher Dk material
D. A hyperflange

The answer is C.

One would rarely polish or attempt to manipulate the central posterior surface of a
rigid lens. Applying polishing pressure to the mid-peripheral and the peripheral
anterior surface would add plus power. Applying polishing pressure to the central
anterior surface would add minus power. - Answer 6. To add minus power to a rigid
contact lens with a rotating modifying spindle, one would:

, NCLE ADVANCED CERTIFICATION
A. Polish the posterior surface of the rigid lens
B. Polish the mid peripheral anterior surface
C. Polish the central anterior surface
D. Polish the peripheral anterior surface

The answer is A.

The keratometer readings indicate the need for a spherical back surface, which
would rule out the use of a bitoric lens. A soft spherical lens would not correct the
moderate amount of refractive astigmatism that is present, nor would the spherical
rigid gas permeable lens. A front surface toric RGP would best meet this patient's
needs since it has a spherical back surface, but has a toric front surface which would
correct the residual astigmatism. - Answer 7. Which lens design would provide the
best visual acuity for a patient with the following information?
K's 42.00@ 180/ 42.50@90
Rx -6.75 +1.75 cx 90

A. Front surface toric rigid gas permeable
B. Spherical rigid gas permeable
C. Soft sphere
D. Bitoric rigid gas permeable

The answer is A.

The wetting angle of a rigid gas permeable material describes how a fluid spreads
over the surface. It is important to remember, however, that wetting angle is a
description of the material outside of the patient's natural ocular environment. Within
minutes of insertion, a rigid lens is encapsulated in the natural tear mucin and the
wetting angle of the material is no longer important. - Answer 8. Which of the
following describes the angle that the edge of a bead of water makes with the
surface of a plastic?

A. Wetting angle
B. Surface angle
C. Bead angle
D. Reflection angle

The answer is B.

The back surface of a rigid lens will usually correct only the astigmatism that is found
on the surface of the cornea. Therefore, when there is significantly more astigmatism
in the refraction than on the surface of the cornea, residual astigmatism is
anticipated. - Answer 9. If a patient has 1.50 D of refractive cylinder and keratometer
readings of 44.00@ 180/ 44 .50 @ 90, a spherical rigid gas permeable lens will:

A. Give the patient their best correctable vision
B. Usually result in residual astigmatism
C. Fit poorly
D. Be uncomfortable

Written for

Institution
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER
Course
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER

Document information

Uploaded on
August 27, 2025
Number of pages
104
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Reviews from verified buyers

Showing all reviews
3 months ago

2 months ago

Thank you for the review.

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BESTGRADE32 Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
10
Member since
1 year
Number of followers
2
Documents
1986
Last sold
6 days ago
BESTGRADE32

EXCELLENT HOMEWORK HELP AND TUTORING,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially;psychology,nursing,human resource management and mathematics assisting students with quality work is my first priority.i ensure scholarly standards in my documents.

3.0

3 reviews

5
1
4
0
3
1
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions