branch circuit - ANS That portion of a wiring system extending beyond the final overcurrent device is called the: Calculated load - ANS The final sum of the computed loads, based on the minimum code requirements, is the Resistance - ANS As compared to #10, a #8 wire of the same Iength has less: 0.001 inch - ANS One circular mil is the area of a circle whose diameter is: 1,000,000 cm - ANS A round bus-bar one inch in diameter, has a circular mil area of: four times as great - ANS A copper wire with twice the diameter of another wire has a current carrying capacity: 10.4 - ANS The specific resistance of copper wire @ 20° C in ohms per circular mil ft. is permit current to flow - ANS Conductance of an electric circuit is that property that will: 1O ohms - ANS The equivalent value of 0.1 mho is directly proportional to its length - ANS The resistance of copper wire is: Feeder - ANS The portion of a wiring system between a point of distribution and the branch circuit overcurrent device is locking - ANS GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____________type not less than 1 1/4 in. from - ANS Where cables or nonmetallic raceways are installed through in joists, rafters, or wood members;holes shall be bored so that the edge of the hole is the nearest edge -of the wood member. located on a balcony accessible only to qualified persons located in a room only accessible to qualified persons elevated 8 ft or more above floor or other working surface - ANS To guard live parts over 50V but less than 600V, equipment is permitted to be 12Ft - ANS Overhead feeder conductors shall have a minimum __________ vertical clearance over residential property and driveways, as well as those commercial areas not subject to truck traffic, where the voltage is limited to 300 volts-to-ground. 36 inches - ANS Where rear access is required to work on de-energized parts on the back of enclosed equipment, a minimum working space of horizontally shall be provided. 50' - ANS What is the maximum run length of a 18AWG fixture wire that is tapped on to a 20 amp branch circuit? power supply failure - ANS When the service disconnecting means is a power-operated switch or circuit breaker, it shall be able to be opened by hand in the event of a 2 in of concrete - ANS Conductors are considered outside a buildings when they are buried under not less than 8 - ANS In straight pull, the length of the box shall not be less than. ____times the trade size of the largest raceway. 18" - ANS At least one receptacle outlet shall be installed within of the top of a show window for each 12 linear feet measured horizontally across its length 1000A - ANS Ground-fault protection of equipment shall be provided fro solidly grounded wye electrical services of more than 150 volts-to-ground, but not exceeding 600V phase-to..phase for each service disconnecting means rated 18" - ANS Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located within ______ of the wall 50V - ANS Exposed live parts of motors and controllers operating at or more between terminals shall be guarded against accidental contact by enclosure or by location 5' - ANS Lighting track shall not be installed less than______ above the finished floor except' where protected from physical damage or where the track operates at less than 30 V rms, open-circuit voltage 4 - ANS Each general care area patient bed location shall be provided with a minimum of_______receptacles, which can be single, duplex, or a combination with each duplex counting as two receptacles Combination Range hood/ Microwave oven - ANS In a Dwelling Unit which appliance is allowed to have a 24" cord with attachment ground plug? 1 - ANS At least_____ 125 V, single phase, 15 A or 20 A, duplex with ground-fault circuit interrupter receptacle shall be provided in each elevator machine room and elevator machinery space. 25A - ANS Lighting systems covered by Article 411 shall have a power supply rated not more than______and not more than 30V 90 - ANS Temporary electrical power and lighting installations shall be permitted for a period not exceeding ____days for Christmas decorative lighting and similar purposes 10' - ANS Lighting systems operating at 30V or less shall not be·installed within_______of pools, spas, fountains, or similar locatipns 12 /40 - ANS Where communications wires and cables and electric light or power conductors are supported by the same pole and are run paralled to each other in span , the·supply service drops of 0-750 volts running above and parallel to communications service drops shall have a minimum separation of _______inches at any point in the span, including the point of and at their attachment to the building, provided the nongrounded conductors are insulated and that a clearance of not less than_______ inches is maintained between the two services at the pole 8 - ANS Communications Wires and cables shall have a vertical clearance of not less the ______feet from all points of roofs above which they pass. Cable Tray - ANS MV cable rated 35 KV cannot be installed in in a straight line - ANS The grounding of communications wires should be run to the grounding electrode: 10 AWG Copper - ANS Service Lateral conductors that supply power to limited loads of a single branch circuit-such as a small polyphase power, controlled water heaters, and similar loads-shall not be smaller than 35KV - ANS Dry type transformers installed indoors rated over._______ shall be installed in a vault. 1 1/2" - ANS Flat:top underfloor raceways over 4 inches, but less 8 inches wide, with a minimum 1 inch spacing between raceways, shall be covered with concrete to a depth of not iess than 1 inch. Raceways spaced less that 1 inch apart shall be covered with a concrete to a depth of

Content preview

Master Electrician Exam Review
Questions With Complete Solutions




A
R
U
LA
C
O
D

, branch circuit - ANS That portion of a wiring system extending beyond the final overcurrent
device is called the:

Calculated load - ANS The final sum of the computed loads, based on the minimum code
requirements, is the




A
Resistance - ANS As compared to #10, a #8 wire of the same Iength has less:

0.001 inch - ANS One circular mil is the area of a circle whose diameter is:




R
1,000,000 cm - ANS A round bus-bar one inch in diameter, has a circular mil area of:

four times as great - ANS A copper wire with twice the diameter of another wire has a



U
current carrying capacity:

10.4 - ANS The specific resistance of copper wire @ 20° C in ohms per circular mil ft. is
LA
permit current to flow - ANS Conductance of an electric circuit is that property that will:

1O ohms - ANS The equivalent value of 0.1 mho is

directly proportional to its length - ANS The resistance of copper wire is:
C

Feeder - ANS The portion of a wiring system between a point of distribution and the branch
circuit overcurrent device is
O


locking - ANS GFCI protection at a carnival is not required for equipment at circuit if the
receptacle is of the ____________type
D



not less than 1 1/4 in. from - ANS Where cables or nonmetallic raceways are installed
through bored.holes in joists, rafters, or wood members;holes shall be bored so that the edge of
the hole is the nearest edge -of the wood member.

located on a balcony accessible only to qualified persons
located in a room only accessible to
qualified persons
elevated 8 ft or more above floor or other working surface - ANS To guard live parts over
50V but less than 600V, equipment is permitted to be

Document information

Uploaded on
August 6, 2025
Number of pages
13
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.39

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocLaura
4.2
(44)
Sold
160
Followers
38
Items
6400
Last sold
1 month ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions