There are six conductors in a raceway connected to 75* rated breakers. Each wire has a 70-amp load using THHN conductors. The minimum size conductor used are #_______ AWG. 310.16 - ANS 4awg Thermal insulation shall not be installed within ______ inch(es) of recessed fixtures. 410.116 - ANS 3inches A 1-inch conduit contains three 3-wire circuits. All conductors are #10 TW. Each circuit consist of two phase conductors, one ground conductor, and one equipment grounding conductor. The maximum ampacity of each phase conductor is _____ amps. 310.15(B)(16), 310.15(B)(3)(a), 310.15(5)(a) - ANS 24amps The volt/ampere rating of a device that consumes 14.5 amps on a 230-volt circuit is _____ watts. A x V = P(Watts) - ANS 3335watts =14.5 x 230 A x V = P(Watts) A 208V, 3 phase heater draws 3598 watts. How many amperes does it draw? I=P/(1.73 x E) - ANS 10amps =3598/(1.73 x 208) =3598/(1.73)square root 3/208) The underwater light fixture shall be installed at least _____ inches below the water level. 680.23(A)(5) - ANS 18inches A general-purpose receptacle shall not be installed on the _____. 680.22(A)(1) - ANS Fence directly south of the pool. JOURNEYMAN ELECTRICAL EXAM 2025 QUESTIONS AND ANSWERS 2 Copyright ©BRIGHSTARS ALL RIGHTS RESERVED 2025 A junction box for the 120-volt wet-niche fixture shall be at least ____ inches above the ground. 680.24(A)(2)(A) - ANS 4inches (min.4" max.8") A GFCI protected _____ receptacle for the pump motor may be installed on the south side of the dwelling unit. 680.22(A)(1)(2) - ANS Locking type A metal fence installed within _____ feet of the pool shall be bonded. 690.26(A)(7) - ANS 5feet The feed to the wet-niche fixture shall be installed in _____. 680.23(B)(2)(a) - ANS A rigid brass conduit A 15 or 20-amp receptacle shall be located within _____ feet of a roof top air conditioner. 210.63 - ANS 25feet The maximum overcurrent protection for eight current carrying #12 THHN conductors in a 1/2" conduit is _____ amps. 310.15(B)(16), 310.15(B)(3)(a), 240.4(D) - ANS 20amps An AC system of 50 to 1000 volts shall be grounded if maximum voltage to ground does not exceed _____ volts. 250.20(B)(1) - ANS 150volts There is a 10 HP, 230 volt, 3 phase motor, code letter G. The maximum standard rating inverse time circuit breaker permitted to serve as branch circuit, short circuit, and ground fault protection when the motor starts the load without difficulty is _____ amps. 430.52, 430.250 - ANS 70amps Type "S" adapters are installed in Edison base fuse holders _____. 240.53(B) - ANS To limit the size of the fuse to be installed A laundry branch circ

Content preview

JOURNEYMAN ELECTRICAL EXAM
2025 QUESTIONS AND ANSWERS


There are six conductors in a raceway connected to 75* rated breakers. Each wire has a 70-amp
load using THHN conductors. The minimum size conductor used are #_______ AWG. 310.16 -
ANS 4awg


Thermal insulation shall not be installed within ______ inch(es) of recessed fixtures. 410.116 -
ANS 3inches


A 1-inch conduit contains three 3-wire circuits. All conductors are #10 TW. Each circuit consist
of two phase conductors, one ground conductor, and one equipment grounding conductor. The
maximum ampacity of each phase conductor is _____ amps. 310.15(B)(16), 310.15(B)(3)(a),
310.15(5)(a) - ANS 24amps


The volt/ampere rating of a device that consumes 14.5 amps on a 230-volt circuit is _____
watts. A x V = P(Watts) - ANS 3335watts =14.5 x 230 A x V = P(Watts)


A 208V, 3 phase heater draws 3598 watts. How many amperes does it draw? I=P/(1.73 x E) -
ANS 10amps =3598/(1.73 x 208) =3598/(1.73)square root 3/208)


The underwater light fixture shall be installed at least _____ inches below the water level.
680.23(A)(5) - ANS 18inches


A general-purpose receptacle shall not be installed on the _____. 680.22(A)(1) - ANS Fence
directly south of the pool.




1 Copyright ©BRIGHSTARS ALL RIGHTS RESERVED 2025

, A junction box for the 120-volt wet-niche fixture shall be at least ____ inches above the ground.
680.24(A)(2)(A) - ANS 4inches (min.4" max.8")


A GFCI protected _____ receptacle for the pump motor may be installed on the south side of
the dwelling unit. 680.22(A)(1)(2) - ANS Locking type


A metal fence installed within _____ feet of the pool shall be bonded. 690.26(A)(7) -
ANS 5feet


The feed to the wet-niche fixture shall be installed in _____. 680.23(B)(2)(a) - ANS A rigid
brass conduit


A 15 or 20-amp receptacle shall be located within _____ feet of a roof top air conditioner.
210.63 - ANS 25feet


The maximum overcurrent protection for eight current carrying #12 THHN conductors in a 1/2"
conduit is _____ amps. 310.15(B)(16), 310.15(B)(3)(a), 240.4(D) - ANS 20amps


An AC system of 50 to 1000 volts shall be grounded if maximum voltage to ground does not
exceed _____ volts. 250.20(B)(1) - ANS 150volts


There is a 10 HP, 230 volt, 3 phase motor, code letter G. The maximum standard rating inverse
time circuit breaker permitted to serve as branch circuit, short circuit, and ground fault
protection when the motor starts the load without difficulty is _____ amps. 430.52, 430.250 -
ANS 70amps


Type "S" adapters are installed in Edison base fuse holders _____. 240.53(B) - ANS To limit
the size of the fuse to be installed


A laundry branch circuit shall be rated at _____ amps. 210.11(C)(2) - ANS 20amps




2 Copyright ©BRIGHSTARS ALL RIGHTS RESERVED 2025

Document information

Uploaded on
August 5, 2025
Number of pages
11
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brightstars
3.3
(38)
Sold
251
Followers
7
Items
13561
Last sold
3 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions