LADWP ELECTRIC STATION OPERATOR (CIRCUIT BREAKERS, DISCONNECTS, TRANSFORMERS) PRACTICE EXAM QUESTIONS WITH CORRECT DETAILED ANSWERS | ALREADY GRADED A+RECENT VERSION 1) Arc - answer The current that continues to flow across the opening contacts of a switch (or across any opening in a circuit) is known as an __________. 2) dielectric - answer Dry, clean air normally has a __________ strength of about 10,000 volts per inch. This means that you would have to apply a voltage greater than 10,000 volts across conductors separated by one inch of air to establish current flow across the separated conductors. 3) resistance - answer Air has a high __________ value so this current flow creates heat. 4) cool - answer Using multiple contacts and rapid opening times helps __________ the arc by reducing the cross sectional area of the arc or by lengthening it. 5) zero - answer Alternating current is easier to interrupt than direct current because periodically (120 times per second in a 60Hz circuit) the current value in the circuit becomes _________. 6) safe - answer Visual disconnection is usually necessary to create __________ working conditions for repair and maintenance crews. 7) series - answer In station designs, circuits are placed in __________ with disconnects. 8) Transformers - answer __________ allow the transfer of electric energy between two circuits that are completely insulated from each other through the use of magnetic induction. 9) induced - answer Back emf or counter emf is also referred to as __________ voltage. 10) magnetic - answer Much stronger __________ fields are obtained if the wire is wound into a coil with many turns of wire. 11) spiral - answer A ___________-shaped coil allows a much stronger field to be created than a flat coil does. 12) self induction - answer When current flow in a coil causes an emf to be induced in itself, it is known as __________. 13) mutual - answer If a second coil is placed in the field of the first coil that is connected to an AC source, the rising and collapsing magnetic field of the first coil will cut across the second coil and will induce an AC voltage in the second coil as well. This is known as __________ induction. 14) inductively - answer When there is no physical or electrical connection between the two coils yet energy is transferred from one coil to the other. The coils are said to be __________ coupled. 15) windings - answer A simple power transformer essentially consists of two 16) Permeability - answer a measure of the ability of a substance to conduct magnetic lines of force. 17) Silicon - answer __________ steel, which has a high permeability rating, is used as a material for manufacturing transformer cores. 18) 98 - answer Well-designed transformers are about _____% efficient. 19) excitation - answer Since they have no moving parts, the only losses are those caused by field __________ when a transformer is energized, and resistance of the core material. 20) Eddy - answer Circulating currents, called __________ currents, cause unwanted heating of the transformer and a loss of energy. 21) silicon - answer By laminating it, using thin sheet of __________ steel or other ferrous alloys sprayed with an insulating material, eddy currents are greatly reduced in transformers cores. 22) Hysteresis - answer The heat and accompanying loss of energy caused by friction of the molecules is called __________. 23) iron - answer The losses of electrical energy that appear as heat and which are cause by hysteresis and eddy currents in the magnetic core are known as __________ losses. 24) switchgear - answer electric equipment that provides a means of centeralizing switch and circuit interupting devices. 25) 3 major parts of CB contacts. - answer contacts, operating mechanism, and control circuits. 26) operating orders-2 - answer clearance needed when encroaching on approach distance. 27) 4.8kv - answer 25" 28) 34.5kv - answer 28" 29) is clearance required when tanks are dropped - answer yes 30) pneumatic uses a? - answer reciever 31) hydraulic mechanism uses? - answer accumilator 32) Operating orders-44 - answer safe handling of SF6 33) should you move bushings under pressure? - answer no 34) classifications of CB's - answer air, oil, gas, and vaccum 35) CB's are capable of breaking currents under? - answer normal and abnormal conditions. 36) current zero - answer used on CB's to extinguish the arc. 37) two common contacts - answer main, and arcing 38) Dielectric strength - answer is a measure of how well a medium can, withstand voltage without conducting electricity. 39) pressure on a medium_____________dielectric strength. - answer increases 40) On vacuum CB, the arc chutes are removed cleaned and inspected for physical damage. - answer False 41) Rubber gloves can be used without leather gloves. - answer False 42) Before working on a CB, always make sure that the CB is? - answer tagged, locked out, and grounds are hung 43) Before testing a CB for power always check your tester against a known source of voltage. - answer hot dead hot 44) most CB's have? - answer Pumps, valves, compressors 45) Which is not classified as a CB - answer hydrolic 46) SF6 - answer Sulfur hexaflouride 47) most important "tool" is? - answer equipment manual 48) contact resistance test; uses a_________________to measure CB contact resistance. - answer ductor micrometer 49) 4 types of CB mechanisms - answer air, hydrolic, spring, and solenoid 50) the term "operation" includes? - answer tripping, closing, and reclosing 51) when CB mechanisms are on "latch" you need air, electrical, or hydraulic energy to make the mechanism operate. - answer false 52) circuit breakers are classified according to their? - answer dielectric medium 53) circuit interruption must occur whether the tripping or opening signal is received with the circuit breaker fully closed or in any partially closed position. - answer true 54) in both pneumatic and hydraulic operating mechanisms, the opening spring is charged as the breaker contacts close. - answer true 55) the purpose of compressed gas in a pneumatic circuit breaker is to drive what? - answer the hydraulic fluid into the operating piston of the main mechanism.

Show more Read less
Institution
LADWP ELECTRIC STATION OPERATOR
Course
LADWP ELECTRIC STATION OPERATOR

Content preview

LADWP ELECTRIC STATION
OPERATOR (CIRCUIT BREAKERS,
DISCONNECTS, TRANSFORMERS)
PRACTICE EXAM QUESTIONS
WITH CORRECT DETAILED
ANSWERS | ALREADY GRADED
A+<RECENT VERSION>



1) Arc - answer The current that continues to flow across the opening
contacts of a switch (or across any opening in a circuit) is known as an
__________.


2) dielectric - answer Dry, clean air normally has a __________ strength
of about 10,000 volts per inch. This means that you would have to apply a
voltage greater than 10,000 volts across conductors separated by one inch
of air to establish current flow across the separated conductors.


3) resistance - answer Air has a high __________ value so this current
flow creates heat.


4) cool - answer Using multiple contacts and rapid opening times helps
__________ the arc by reducing the cross sectional area of the arc or by
lengthening it.

,5) zero - answer Alternating current is easier to interrupt than direct
current because periodically (120 times per second in a 60Hz circuit) the
current value in the circuit becomes _________.


6) safe - answer Visual disconnection is usually necessary to create
__________ working conditions for repair and maintenance crews.


7) series - answer In station designs, circuits are placed in __________
with disconnects.


8) Transformers - answer __________ allow the transfer of electric
energy between two circuits that are completely insulated from each other
through the use of magnetic induction.


9) induced - answer Back emf or counter emf is also referred to as
__________ voltage.


10) magnetic - answer Much stronger __________ fields are
obtained if the wire is wound into a coil with many turns of wire.


11) spiral - answer A ___________-shaped coil allows a much
stronger field to be created than a flat coil does.


12) self induction - answer When current flow in a coil causes an
emf to be induced in itself, it is known as __________.


13) mutual - answer If a second coil is placed in the field of the first
coil that is connected to an AC source, the rising and collapsing magnetic
field of the first coil will cut across the second coil and will induce an AC
voltage in the second coil as well. This is known as __________
induction.

, 14) inductively - answer When there is no physical or electrical
connection between the two coils yet energy is transferred from one coil
to the other. The coils are said to be __________ coupled.


15) windings - answer A simple power transformer essentially
consists of two


16) Permeability - answer a measure of the ability of a substance to
conduct magnetic lines of force.


17) Silicon - answer __________ steel, which has a high
permeability rating, is used as a material for manufacturing transformer
cores.


18) 98 - answer Well-designed transformers are about _____%
efficient.


19) excitation - answer Since they have no moving parts, the only
losses are those caused by field __________ when a transformer is
energized, and resistance of the core material.


20) Eddy - answer Circulating currents, called __________
currents, cause unwanted heating of the transformer and a loss of energy.


21) silicon - answer By laminating it, using thin sheet of
__________ steel or other ferrous alloys sprayed with an insulating
material, eddy currents are greatly reduced in transformers cores.


22) Hysteresis - answer The heat and accompanying loss of energy
caused by friction of the molecules is called __________.

Written for

Institution
LADWP ELECTRIC STATION OPERATOR
Course
LADWP ELECTRIC STATION OPERATOR

Document information

Uploaded on
July 24, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
jervismuthami Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
10
Member since
1 year
Number of followers
0
Documents
573
Last sold
2 months ago

4.5

2 reviews

5
1
4
1
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions