Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

IL SEPTIC INSTALLERS EXAMINATION 2025 WITH 100% CORRECT ANSWERS

Rating
-
Sold
-
Pages
21
Grade
A+
Uploaded on
22-07-2025
Written in
2024/2025

Public Sewer Connection - CORRECT ANSWERPrivate residence must connect if w/in 300' or for any commercial bldg. w/in 300' that has flows less than 1500 gpd. Commercial w/ flows = to or greater than 1500 gpd must connect if sewer is w/in 1000'. Unless physical barrier, ordinance, or cannot be done w/ individual line (4" line)-then PSD system is OK. Acceptable Pipe Materials - CORRECT ANSWERVitrified clay, ductile iron, or plastic. Anything after the tank or from distribution box has to be vitrified clay or plastic. Schedule 40 or Greater - CORRECT ANSWERunder roads, driveways, or parking areas Gravity Slope - CORRECT ANSWERDiameter: 4" pipe + min. slope of 12" per 100' Building sewers in excess of 50' should have what? - CORRECT ANSWERA C/O @ least every 50' from building to tank, distribution box, or ATU Creviced Limestone Formation - CORRECT ANSWERSS system cannot be installed where bottom of system is less than 4' from top of limestone If limestone is known to be present a soil test must be done @ least 4' deeper than where the bottom of the trench will be

Show more Read less
Institution
IL SEPTIC INSTALLERS
Course
IL SEPTIC INSTALLERS

Content preview

IL SEPTIC INSTALLERS EXAMINATION
2025 WITH 100% CORRECT ANSWERS

Public Sewer Connection - CORRECT ANSWER✔✔Private residence must connect if w/in 300' or
for any commercial bldg. w/in 300' that has flows less than 1500 gpd. Commercial w/ flows = to
or greater than 1500 gpd must connect if sewer is w/in 1000'.

Unless physical barrier, ordinance, or cannot be done w/ individual line (4" line)-then PSD
system is OK.



Acceptable Pipe Materials - CORRECT ANSWER✔✔Vitrified clay, ductile iron, or plastic.

Anything after the tank or from distribution box has to be vitrified clay or plastic.



Schedule 40 or Greater - CORRECT ANSWER✔✔under roads, driveways, or parking areas



Gravity Slope - CORRECT ANSWER✔✔Diameter: 4" pipe + min. slope of 12" per 100'



Building sewers in excess of 50' should have what? - CORRECT ANSWER✔✔A C/O @ least every
50' from building to tank, distribution box, or ATU



Creviced Limestone Formation - CORRECT ANSWER✔✔SS system cannot be installed where
bottom of system is less than 4' from top of limestone



If limestone is known to be present a soil test must be done @ least 4' deeper than where the
bottom of the trench will be



How far away can quick disconnect be? - CORRECT ANSWER✔✔no more than 50' away from the
device & w/in sight of

,Experimental Use Permits - CORRECT ANSWER✔✔min. of 10 experimental systems installed b4
unconditional approval granted. Permit valid for 2 yrs & evaluated @ end of 2 yrs.



2 options for garbage grinders - CORRECT ANSWER✔✔1. solids retention tank btwn WW source
& septic tk. for kitchen waste only. Needs to be 50% of the size of the designed septic tank w/ a
min. of 500 gals.

2. A septic tank receiving all flows sized as 50% of the septic tank size + septic tank size. i.e.,
septic tk = 1500 gals. /2 = 750 + 1500 = 2250 (would need 2500 gal tk)



How long should a homeowner keep maint. records for their system? - CORRECT
ANSWER✔✔the life of the system



When should the 1st maintenance of a septic tank after installation be completed for a
residence? - CORRECT ANSWER✔✔Prior to or within 3 yrs. After initial inspection it can be done
once every 5 yrs. Can be done by everyone + homeowner



If sludge layer /suspended solids are greater than 33% . . . - CORRECT ANSWER✔✔Must pump
tank and perform maintenance



When should a septic system be evaluated initially after installation for a non-residential bldg? -
CORRECT ANSWER✔✔prior to or w/in 3 yrs. After that it should be done @ least every 3 yrs.

Owner cannot do. has to be engineer, env. health practitioner, member of dept, HD, or septic
contractor



Aerobic Treatment Unit Evaluations - CORRECT ANSWER✔✔1 every 6 mos @ least (same ppl) +
HOMEOWNER as long as they follow manufacturer's requirements & proper maintenance



What is the maint. schedule for SFs & WSPs w/ surface discharges? - CORRECT ANSWER✔✔@
least 1 per yr. + H.O. if rules r followed. Pumped when solids & scum greater than 33%

, Can a H.O. install & maintain a septic system on his/her property? - CORRECT ANSWER✔✔Yes



Who can perform the excavation for a septic system? - CORRECT ANSWER✔✔A licensed
installer (employee while supervised) or the property owner.



What is the min. size tank for flows UP TO 500 gpd? - CORRECT ANSWER✔✔750 gals.



If flows are greater than 500 gpd, how do you size the tank? - CORRECT ANSWER✔✔Tank size
should be = to @ least 1.5x the estimated sewage flow



How do you size a tank(s) for flows greater than 1350 gpd? - CORRECT ANSWER✔✔U must use
multiple tks. in a series or multiple compartment tks. where the 1st tank or the 1st comp. in a
multicomp. tk. is 1/2-2/3 of the total required capacity. of the tank(s)



How do you size the tank for a raised filter bed for a residence? - CORRECT ANSWER✔✔It has to
be an NSF 40 batch treatment system. The aeration tank has to be 2x the daily flow



How do you size the tank for a RFB for a commercial bldg? - CORRECT ANSWER✔✔The aeration
tk. has to be 3x the daily flow.



Multiple tanks in a series connected @ btm for flow equalization can be used



How are RFB sidewalls sized? - CORRECT ANSWER✔✔3:1 ratio



How are distribution lines for RFBs? - CORRECT ANSWER✔✔4" perforated pipe on 15" centers

Written for

Institution
IL SEPTIC INSTALLERS
Course
IL SEPTIC INSTALLERS

Document information

Uploaded on
July 22, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$20.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QUILLSKY Yale University
View profile
Follow You need to be logged in order to follow users or courses
Sold
524
Member since
3 year
Number of followers
275
Documents
13964
Last sold
2 weeks ago
,STUDY GUIDES,TESTBANKS AND QUALITY EXAMS IS THE KEY TO STUDENTS CAREER EXCELLENCE!!!

On this page, you find all documents, package deals, and flashcards offered by seller MAXGRADES WELCOME TO MAXGRADES ALL THE BEST !!!!!!

3.6

131 reviews

5
51
4
23
3
29
2
6
1
22

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions