Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 10 pages
Exam (elaborations)

NYC FUEL GAS CODE EXAM NEWEST 2025 ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+

Document preview thumbnail
Preview 2 out of 10 pages

NYC FUEL GAS CODE EXAM NEWEST 2025 ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ Where is the union located for a gas appliance? - CORRECT ANSA union fitting shall be provided for appliance connected by rigid metallic pipe. Such unions shall be accessible and located within 6 feet of the appliance. Where is gas piping permitted? - CORRECT ANSGas piping may be installed in public corridors in residential buildings that do not have floors below grade or in multi-use buildings that have a residential occupancy in accordance with the following, Gas piping shall be permitted to be installed within a public corridor at the lowest level of the building or the lowest residential level of the building. All gas valves located within the public corridor shall be accessible for maintenance and inspection. Gas pressure within the public corridor piping shall not exceed 1/2 psi. The completed piping within the public corridor is to be tested and proven tight at 10 psig for a minimum of 30 minutes. The public corridor shall be ventilated in accordance with the New York City Mechanical Code. The pipe shall not be installed in a return air plenum. Pipes must be welded. How much must piping for other than dry gas conditions be sloped? - CORRECT ANSNot less the 1/4 inch in 15 feet to prevent traps. Hanger spacing for 3/4 inch and 1 inch gas pipe - CORRECT ANS8 feet When is water permitted for testing? - CORRECT ANSFresh water may be used the test medium where the required test pressure exceeds 100 p.s.i.g. 2 When do need temporary restraints when testing? - CORRECT ANSExpansion joints shall be provided with temporary restraints, if required, for the additional trust load under test. What must each digital gauge used to measure pressure in the magnitude of 3 and higher read? - CORRECT ANSThe gauge shall have a minimum reading of 1/100 of a p.s.i.g. Where pipe passes through an outside wall, this piping shall not be less than how many inches outside of the buildings? - CORRECT ANSWith conduit going through the wall, pipe shall not be less than 4 inches outside the building and sleeve shall be at least 1 inch beyond the inner side of the wall. Pipe shall be vented above grade to the outdoors and shall be installed so as to prevent the entrance of water and insects. Threaded pipe may be used up to 4 inches at pressure no greater than? - CORRECT ANS1/2 p.s.i.g. Gas piping going through the foundation wall of a building, shall be protected by? - CORRECT ANSEncasing it in a protective sleeve. Gas piping in solid floor shall be installed in a conduit of schedule 40 pipe. This conduit shall extend not less than how many inches above the floor? - CORRECT ANS2 inches. 3 All exterior gas piping shall be elevated not less than how many inches above ground and roof surfaces? - CORRECT ANS3 1/2 inches. The untreated portion of gas piping outlets must extend at least how many inches through finished ceilings and walls? - CORRECT ANS1 inch Underground piping systems shall be installed a minimum depth of, how many inches below grade? - CORRECT ANS24 inches The unthreatened portion of gas piping outlets extending through floors or outdoor patios and slabs must extend at least, how many inches above them? - CORRECT ANS2 inches What gas is prohibited from being used for testing gas piping? - CORRECT ANSOxygen The testing duration for gas piping with distribution pressures over 1/2 p.s.I.g through 5 p.s.I.g is? - CORRECT ANS50 p.s.I.g for a minimum of 30 minutes. Supports for 1 inch gas piping shall be spaced no more than, how many feet apart? - CORRECT ANS8 feet The gas shut off valve shall be within how many feet of the appliance? - CORRECT ANS6 feet 4 Located on the supply side of the meter, every meter shall be equipped with a what? - CORRECT ANSShut off valve Gas distribution piping with pressures up to 1/2 p.s.I.g, shall be tested at a pressure of how many P.s.I.g? and a minimum of how many minutes? - CORRECT ANS3 p.s.I.g for 30 minutes What joints is acceptable in gas piping? - CORRECT ANSThreaded, flanged and welded Gas meters and service piping is found in what part of the F.G.C? - CORRECT ANSAppendix E What is the final step before you restore gas service after a shutdown? - CORRECT ANSThe gas utility company shall be notified by owner or his or her authorized representative. All factory applied coated and wrapped pipe shall be pressure tested at a minimum of what p.s.I.g? - CORRECT ANS90 p.s.i.g. The holder of the plumbing permit shall give how many days prior written notice for inspection? - CORRECT ANS2 days Gas leak detection methods include? - CORRECT ANSAn approved gas detector, a noncorrosive leak detection fluid and other approved leak detection methods.

Content preview

1


NYC FUEL GAS CODE EXAM NEWEST 2025
ACTUAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+

Where is the union located for a gas appliance? - CORRECT ANS>>A union fitting shall be
provided for appliance connected by rigid metallic pipe. Such unions shall be accessible and
located within 6 feet of the appliance.


Where is gas piping permitted? - CORRECT ANS>>Gas piping may be installed in public
corridors in residential buildings that do not have floors below grade or in multi-use buildings
that have a residential occupancy in accordance with the following, Gas piping shall be
permitted to be installed within a public corridor at the lowest level of the building or the
lowest residential level of the building. All gas valves located within the public corridor shall
be accessible for maintenance and inspection. Gas pressure within the public corridor piping
shall not exceed 1/2 psi. The completed piping within the public corridor is to be tested and
proven tight at 10 psig for a minimum of 30 minutes. The public corridor shall be ventilated in
accordance with the New York City Mechanical Code. The pipe shall not be installed in a
return air plenum. Pipes must be welded.


How much must piping for other than dry gas conditions be sloped? - CORRECT ANS>>Not less
the 1/4 inch in 15 feet to prevent traps.


Hanger spacing for 3/4 inch and 1 inch gas pipe - CORRECT ANS>>8 feet


When is water permitted for testing? - CORRECT ANS>>Fresh water may be used the test
medium where the required test pressure exceeds 100 p.s.i.g.

, 2



When do need temporary restraints when testing? - CORRECT ANS>>Expansion joints shall be
provided with temporary restraints, if required, for the additional trust load under test.


What must each digital gauge used to measure pressure in the magnitude of 3 and higher
read? - CORRECT ANS>>The gauge shall have a minimum reading of 1/100 of a p.s.i.g.


Where pipe passes through an outside wall, this piping shall not be less than how many
inches outside of the buildings? - CORRECT ANS>>With conduit going through the wall, pipe
shall not be less than 4 inches outside the building and sleeve shall be at least 1 inch beyond
the inner side of the wall. Pipe shall be vented above grade to the outdoors and shall be
installed so as to prevent the entrance of water and insects.


Threaded pipe may be used up to 4 inches at pressure no greater than? - CORRECT ANS>>1/2
p.s.i.g.


Gas piping going through the foundation wall of a building, shall be protected by?
- CORRECT ANS>>Encasing it in a protective sleeve.


Gas piping in solid floor shall be installed in a conduit of schedule 40 pipe. This conduit shall
extend not less than how many inches above the floor? - CORRECT ANS>>2 inches.

Document information

Uploaded on
July 16, 2025
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Nurslink
3.5
(27)
Sold
237
Followers
72
Items
1693
Last sold
2 weeks ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions