Question: With an R-410A condensing pressure of 395 psig and a liquid line temperature of 108°F what is the sub cooling temperature? Ans: D. 8°F Question: When performing maintenance on a heat pump the technician should check the outdoor fan to be certain: Ans: C. The fan runs freely without binding or vibrations Question: The continuity of a fuse in a disconnect should be tested by checking resistance: Ans: A. With power off Question: Why does the outdoor fan on a heat pump stopped during defrost? Ans: C. Minimize defrost time Question: It technician measures the return air temperature of 100,000 BTU output furnace to be 65°F and the supply side air temperature is 135°F. what is the SCFM(standard CFM)? Page | 2 Ans: B. 1323 SCFM Question: The following measurements are recorded on an operating heat pump system. The heat pump is operating with the compressor only with no auxiliary heat. -heat pump only supply air temperature 92°F, heat pump only return air temperature 70°F, outdoor temperature 54°F, supply air temp./Auxiliary heat on 115°F, return air temp./Auxiliary heat on 70°F, CFM 1228 What is the heating capaci

Content preview

Page | 1



HPSV exam Questions with Detailed
Verified Answers

Question: With an R-410A condensing pressure of 395 psig and a liquid line
temperature of 108°F what is the sub cooling temperature?


Ans: D. 8°F


Question: When performing maintenance on a heat pump the technician
should check the outdoor fan to be certain:


Ans: C. The fan runs freely without binding or vibrations


Question: The continuity of a fuse in a disconnect should be tested by
checking resistance:


Ans: A. With power off


Question: Why does the outdoor fan on a heat pump stopped during defrost?


Ans: C. Minimize defrost time


Question: It technician measures the return air temperature of 100,000 BTU
output furnace to be 65°F and the supply side air temperature is 135°F. what is
the SCFM(standard CFM)?

, Page | 2

Ans: B. 1323 SCFM


Question: The following measurements are recorded on an operating heat
pump system. The heat pump is operating with the compressor only with no
auxiliary heat.
-heat pump only supply air temperature 92°F, heat pump only return air
temperature 70°F, outdoor temperature 54°F, supply air temp./Auxiliary heat
on 115°F, return air temp./Auxiliary heat on 70°F, CFM 1228
What is the heating capacity of the unit in BTU/H?


Ans: D. 29,177 btu/h


Question: R-410A Vapor in line diameters with links 50 feet or less are
typically specified for a vapor pressure drop that does not exceed what value?


Ans: B. 3 psi


Question: Which of the following is used to make accurate residential loan
calculations?


Ans: B. ACCA manual J


Question: The following conditions exist in a circuit that supplies power to
three parallel loads:
One load is resistive, one load is capacitive, one load is inductive
The total current in the circuit when operating will be:

, Page | 3

Ans: D. The sum of the currents through each load


Question: what condition can cause a reduction from design capacity in a
heat pump?


Ans: A. An undersized vapor line


Question: What can happen if defrost runoff is not properly drained away?


Ans: B. Ice can build up on the bottom of the coil


Question: Undersized ductwork often cause:


Ans: C. High air quantities and high static pressures


Question: Where is the sensor of an outdoor ambient thermostat for a heat
pump system typically installed?


Ans: C. In the entering airstream to the outdoor coil


Question: What effect does a low charge have on the switch over operations
of a reversing valve?


Ans: C. Reversing valves are less likely to shift if charge is very low


Question: The technician is using an analog multi meter to check a run
capacitor. With the meter set to OHMS the needle swings towards zero and
then slowly rise is toward infinity. What does this tell the technician about the
capacitor?

Document information

Uploaded on
July 11, 2025
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Ivie
3.4
(7)
Sold
32
Followers
1
Items
8533
Last sold
1 month ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions