A fuel oil storage tank cannot be installed: correct answers In the furnace room within 5 feet of the heating unit. What temperature does a thermal wheel automatically activate at? correct answers 165F Who inspects an oil burner installation? correct answers Local Fire Department. Any valve used on an oil burner installation must be a: correct answers Fusible Valve. What Form is used to pull an Oil Burner Permit? correct answers Form 1. What size pipe is used to cross connect tank outlet piping? correct answers 1/2 Inch. When is an OSV or Oil Safety Switch used? correct answers On existing installations when a burner, boiler, furnace or tank is replaced. When must you install a draft regulator? correct answers On every new installation and when not exempted by the manufacturer. (Both A and C). As of January 1st, 2014. The maximum safety timing for an oil burner safety lockout switch must be no more than? correct answers 15 Seconds. What type of boiler must be equipped with a low-water cutoff? correct answers Water boilers over 500,000 Btu's and All steam boilers. (Both A and B). What device must be equipped with an air proving switch? correct answers A power-venter and A power-venter. (Both B and C). All new oil burner controls must be: correct answers Interrupted ignition. Hot water boilers must be equipped with a low-water cutoff when the heat input is greater than: correct answers 400,000 Btu's. How far must continuous concrete slab extend beyond the tank perimeter? correct answers 8 Inches. All protective, control and emergency devices shall be series connected from the electrical distribution panel: correct answers Through the emergency switch, through the thermal switch, to the service switch in the ungrounded line conductor. If the ceiling above the burner boiler or burner furnace exceeds 12 feet in height, an additional thermal switch shall be installed at a height of _______ and connected in series with the lower switch. correct answers 10 Feet. An oil safety valve can perform the following functions: correct answers Reduce pressure from its inlet to its outlet, and Prevent gravity flow. (Both A and C).

Content preview

Oil Burners MA Pt. 1 || QUESTIONS WITH COMPLETE
SOLUTIONS!!
A fuel oil storage tank cannot be installed: correct answers In the furnace room within 5 feet
of the heating unit.

What temperature does a thermal wheel automatically activate at? correct answers 165F

Who inspects an oil burner installation? correct answers Local Fire Department.

Any valve used on an oil burner installation must be a: correct answers Fusible Valve.

What Form is used to pull an Oil Burner Permit? correct answers Form 1.

What size pipe is used to cross connect tank outlet piping? correct answers 1/2 Inch.

When is an OSV or Oil Safety Switch used? correct answers On existing installations when a
burner, boiler, furnace or tank is replaced.

When must you install a draft regulator? correct answers On every new installation and when
not exempted by the manufacturer. (Both A and C).

As of January 1st, 2014. The maximum safety timing for an oil burner safety lockout switch
must be no more than? correct answers 15 Seconds.

What type of boiler must be equipped with a low-water cutoff? correct answers Water boilers
over 500,000 Btu's and All steam boilers. (Both A and B).

What device must be equipped with an air proving switch? correct answers A power-venter
and A power-venter. (Both B and C).

All new oil burner controls must be: correct answers Interrupted ignition.

Hot water boilers must be equipped with a low-water cutoff when the heat input is greater
than: correct answers 400,000 Btu's.

How far must continuous concrete slab extend beyond the tank perimeter? correct answers 8
Inches.

All protective, control and emergency devices shall be series connected from the electrical
distribution panel: correct answers Through the emergency switch, through the thermal
switch, to the service switch in the ungrounded line conductor.

If the ceiling above the burner boiler or burner furnace exceeds 12 feet in height, an
additional thermal switch shall be installed at a height of _______ and connected in series
with the lower switch. correct answers 10 Feet.

An oil safety valve can perform the following functions: correct answers Reduce pressure
from its inlet to its outlet, and Prevent gravity flow. (Both A and C).

Document information

Uploaded on
July 2, 2025
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProPerfomer
3.8
(84)
Sold
443
Followers
322
Items
8859
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions