Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 1 out of 3 pages
Exam (elaborations)

Massachusetts Oil burner Practice || EXAM-STYLE QUESTIONS WITH CORRECT SOLUTIONS!!

Document preview thumbnail
Preview 1 out of 3 pages

The cross connection between two supply tanks shall not exceed? correct answers 660 gallons When is an automatic draft control not required? correct answers When the equipment is designed to control the draft. Combustion performance testing can indicate: correct answers Improper air oil mixture, too much combustion air, and low pump pressure. If a second oil-burning appliance is installed in a single chimney, you must insure: correct answers Sufficient draft is available for safe operation of all connected equipment. Delayed ignition can be caused by: correct answers Weak ignition transformer You should replace the oil burner nozzle with: correct answers The manufacturers recommended nozzle spray pattern and spray angle. Viscosity problems can be corrected by: correct answers Decreasing the nozzle size and increasing the pump pressure accordingly The minimum operating pressure of an oil pump is: correct answers 100 PSI If a stack relay fails you, must? correct answers Replace it with an approved type controller Aquastats are normally found on what type of heating systems? correct answers Hydronic Airstats are found on what type of heating systems? correct answers Forced warm air systems Under sized returns on a warm air system can result in what? correct answers Short cycling of the oil burner Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a steam system? correct answers Some radiators not heating quickly enough Low boiler water temperature in a hydronic hot water system may be caused by? correct answers Undersized oil burner nozzles Delayed opening oil valves are used to? correct answers Allow oil pump to come up to speed If a steam boiler is to be installed with an automatic feeder it must also have: correct answers A backflow prevention device How can a damaged heat exchanger be detected on a forced warm air system? correct answers With a smoke trace candle

Content preview

Massachusetts Oil burner Practice || EXAM-STYLE
QUESTIONS WITH CORRECT SOLUTIONS!!
The cross connection between two supply tanks shall not exceed? correct answers 660
gallons

When is an automatic draft control not required? correct answers When the equipment is
designed to control the draft.

Combustion performance testing can indicate: correct answers Improper air oil mixture, too
much combustion air, and low pump pressure.

If a second oil-burning appliance is installed in a single chimney, you must insure: correct
answers Sufficient draft is available for safe operation of all connected equipment.

Delayed ignition can be caused by: correct answers Weak ignition transformer

You should replace the oil burner nozzle with: correct answers The manufacturers
recommended nozzle spray pattern and spray angle.

Viscosity problems can be corrected by: correct answers Decreasing the nozzle size and
increasing the pump pressure accordingly

The minimum operating pressure of an oil pump is: correct answers 100 PSI

If a stack relay fails you, must? correct answers Replace it with an approved type controller

Aquastats are normally found on what type of heating systems? correct answers Hydronic

Airstats are found on what type of heating systems? correct answers Forced warm air systems

Under sized returns on a warm air system can result in what? correct answers Short cycling of
the oil burner

Incorrect nozzle selection in regards to gallon per hour, can result in what problems in a
steam system? correct answers Some radiators not heating quickly enough

Low boiler water temperature in a hydronic hot water system may be caused by? correct
answers Undersized oil burner nozzles

Delayed opening oil valves are used to? correct answers Allow oil pump to come up to speed

If a steam boiler is to be installed with an automatic feeder it must also have: correct answers
A backflow prevention device

How can a damaged heat exchanger be detected on a forced warm air system? correct
answers With a smoke trace candle

Document information

Uploaded on
July 2, 2025
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProPerfomer
3.8
(84)
Sold
443
Followers
322
Items
8859
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions