ARRT CI ACTUAL EXAM REVIEW 2025 \NEWEST VERSION
WITH COMPLETE QUESTIONS AND CORRECT DETAILED
ANSWERS \VERIFIED SOLUTIONS ALREADY GRADED A+
|ACTUAL EXAM ARRT CI \LATEST UPDATE
What is the area The power factor of an automatic power injector
relationship indicated by indicates the area relationship of the power cylinder
the power factor of an to the syringe
automated injector?
1. power cylinder
2. catheter
3.syringe
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3
How long is the injection Answer: C
time for 12ml of contrast Injection time is calculated as volume/time, so 12/2.5 equals 4.8
seconds
media delivered at 2.5
ml/sec?
A. 0.2 sec
B. 2.5 sec
C. 4.8 sec
D. 30 sec
/ 1/44
,7/1/25, 8:18 PM ARRT CI Review
Which of the following Answer: A
describe exact Exact framing of a fluoroscopic image for Cine film
framing of a fluoroscopic recording includes the entire fluoroscopic with the
image in a Cine film circular image within the square film frame
system?
1. the circular image
intensifier image is
included within the
square film frame.
2. the diameter of the
intensifier image is equal
to the mean of the
transverse dimensions of
the useful square film area.
3. The diameter of the
intensifier image is equal
to the diagonal
dimensions of the useful
square film area.
A. 1 only
B. 2 only
C. 3 only
D. 1,2, and 3
Which of the following can Answer: D
be avoided by proper use of Proper use of an automatic injector pressure control
a automatic injector pressure avoids vessel damage, catheter whipping, and
limit control? catheter damage.
1. Vessel damage
2. catheter whipping
2. catheter breakage
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1,2, and 3
What effect does the Answer: A
addition of side holes in a
catheter have on the total
flow rate?
A. 10 to 20 percent increase
B. 50 to 60 percent increase
/ 2/44
,7/1/25, 8:18 PM ARRT CI Review
C. 10 to 20 percent decrease
D. 50 to 60 percent decrease
What is the area Answer: B
relationship indicated by
the power factor of an
automated injector?
1. power cylinder
2. catheter
3.syringe
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3
Which of the following devices Answer: C
permits
simultaneoulsy cine
recording and viewing of a
fluoroscopic image?
A. Grid biased X-RAY tube
B. High frequency generator
C. beam splitting mirror
D. roll film camera
Which of the following are Answer: A
important
considerations when selecting
the proper diameter of a
guide wire?
1. size of vascular catheter
2. vessel size
3. contrast media bolus volume
A. 1 and 2 only
B. 1 and 3 only
C. 2 and 3 only
D. 1, 2, and 3
Which of the following is Answer: D
not a proper technique of
custom shaping of a catheter?
A. the cut tip should be
smooth
/ 3/44
, 7/1/25, 8:18 PM ARRT CI Review
B. shape the tip in hot water
C. fix the tip in cold water
D. punch side hole opposite
one another
Which of the following are Answer: A
inversely
proportional to contrast
delivery rate?
1. catheter length
2. catheter diameter
3.more side holes
A. 1 only
B. 2 only
C. 3 only
D. 1, 2, and 3
How long is the injection time Answer: C
for 30ml of contrast media Injection time is calculated as volume/time, so 30/3.7=8.1 seconds.
delivered at 3.7ml/sec?
A. 0.1sec
B. 4.5sec
C. 8.1sec
D. 111sec
What is the primary reason Answer: A
that guide wires must have a The primary reason guide wires must have a flexible tip
flexible tip? is to permit bending and avoid vascular wall damage.
A. to permit bending and
avoid damage to vascular
walls
B. to permit whip lash to occur
C. to avoid unraveling
D. to avoid clotting
What term describes the Answer C
thin wire along which a
catheter will be threaded
when it is inserted into a
vessel?
A. French catheter
B. Seldinger needle
C. guide wire
D. J wire
/ 4/44