Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

NGWA AUGERING & MONITORING WELL PRACTICE EXAM QUESTIONS WITH CORRECT DETAILED ANSWERS | ALREADY GRADED A+RECENT VERSION

Rating
5.0
(1)
Sold
2
Pages
17
Grade
A+
Uploaded on
16-06-2025
Written in
2024/2025

NGWA AUGERING & MONITORING WELL PRACTICE EXAM QUESTIONS WITH CORRECT DETAILED ANSWERS | ALREADY GRADED A+RECENT VERSION 1. The most important function of the drilling fluids in rotary drilling is - answer to bring cuttings from the bottom of the hole. 2. In selecting a fluid for a well, the following consideration should be given. - answer fluid should be selected on the basis of the circumstances of each individual well. 3. When selecting a screen for a monitoring well, which of the following is not a consideration? - answer type of well head seal. 4. The purpose for making a sieve analysis of sand and gravel formations in monitoring well construction is... - answer ... To select the proper screen slot opening. 5. When backfilling the annulus of a monitoring well after the filter pack and seal are in place, the best material to use is... - answer ... Cement and/or bentonite grout materials. 6. Which material is best for a typical 2-inch monitoring well filter pack? - answer coarse clean silica sand. 7. Without regard to sampling parameters, which of the four typical types of materials used for monitoring wells would deteriorate the quickest in a low ph environment? - answer steel. 8. A flush mount well cover should have... - answer ... Concrete in the base. 9. If decontamination procedures are not followed, what piece(s) of drill equipment is (are) most likely to contaminate a well? - answer 1. Drill rods. 2. Augers. 3. Samplers. 10. The purpose for a double cased monitoring well would be... - answer ... To prevent migration of contamination between aquifers. 11. Which of the following is usually added to cement grout to reduce shrinkage? - answer bentonite. 12. To protect against suspected dust, mist, fumes, and vapors, personnel should begin operations by having... - answer ... A filtration respirator. 13. The site specific safety plan calls for level d ppe. Level d ppe includes... - answer hard hat, safety glasses, steel toe shoes. 14. When drilling monitoring wells in urban areas, which of the following should be taken into consideration? - answer 1. Access to drilling sites. 2. Underground utilities. 3. Overhead utilities. 15. Under what conditions will bentonite pellets not swell to their maximum size? - answer in highly mineralized water. 16. How far can a well screen section be moved vertically after a filter pack and bentonite seal have been placed? - answer the length of the filter pack above the screen. 17. The purpose of taking ground water samples while advancing the hole it... - answer ... To determine containment concentrations at specific intervals in the aquifer. 18. What standard method is used for decontaminating equipment and materials does not belong? - answer lubricate equipment with petroleum products after cleaning. 19. Which of the following factors can alter the quality of a ground water sample taken from a monitoring well? - answer 1. Solvent used to weld pvc casing together. 2. Improperly stored and handled casing. 3. Drilling fluid. 20. Which of the following is not true? - answer the spt is performed by driving a standard sampler 9 inches into the soil using a 100 lb hammer. 21. The most common use of a piezometer is... - answer ... For water quality sampling. 22. A "travel blank" is a special sample vial that... - answer ... Contains astm type ii reagent water and is shipped to the laboratory with ground water samples that are to be tested for vocs. 23. Which of the following is usually not recorded on either the driller's log or the geologist's log during the drilling of an environmental investigation boring? - answer the chemical-analytical laboratory where the samples are sent. 24. Doubling the inside diameter of casing in a well will increase its cross sectional area by... - answer ... 4 times. 25. When developing a monitoring well, what factor(s) will determine the well development method to be used? - answer well construction and geologic formation. 26. The drilling method used to construct a monitoring well should... - answer ... Minimize the risk of subsurface contamination. 27. The primary item which dictates the type of drilling equipment to be used on a site is... - answer ... Geology. 28. The commonly used hollow-stem auger system for monitoring well installations... - answer ... Should include an auger head than can be machined to accent a plate that facilitates well installation below the ground water level. 29. Which is not a component of a monitoring well rig? - answer mud pump. 30. What is the minimum size hollow-stem auger, casing, or borehole used for installation of a typical 2-inch well? - answer 4.25 in. 31. The best drilling method to use in a highly toxic contaminated limestone formation that would produce the least fluid management would be? - answer cable tool 32. Monitoring wells are commonly installed... - answer ... Downgradient of a landfill to determine ground water contamination. 33. Which of the following is not an impermeable material? - answer sand 34. Due to the advanced technology, today's monitoring equipment and material... - answer ... 35. Glacial drift is defined as... - answer unconsolidated sediment transported by glaciers and disposed and deposited directly on land or sea. 36. What type of material(s) is(are) typically on monitor wells for a seal above the filter packs? - answer bentonite pellets. 37. The most efficient method of drilling a bedrock monitoring well would be... - answer ... Air rotary with a down-hole hammer.

Show more Read less
Institution
NGWA Groundwater
Course
NGWA Groundwater

Content preview

NGWA AUGERING & MONITORING
WELL
PRACTICE EXAM QUESTIONS
WITH CORRECT DETAILED
ANSWERS | ALREADY GRADED
A+<RECENT VERSION>




1. The most important function of the drilling fluids in rotary drilling is -
answer to bring cuttings from the bottom of the hole.


2. In selecting a fluid for a well, the following consideration should be
given. - answer fluid should be selected on the basis of the
circumstances of each individual well.


3. When selecting a screen for a monitoring well, which of the following is
not a consideration? - answer type of well head seal.


4. The purpose for making a sieve analysis of sand and gravel formations in
monitoring well construction is... - answer ... To select the proper
screen slot opening.

,5. When backfilling the annulus of a monitoring well after the filter pack
and seal are in place, the best material to use is... - answer ... Cement
and/or bentonite grout materials.


6. Which material is best for a typical 2-inch monitoring well filter pack? -
answer coarse clean silica sand.


7. Without regard to sampling parameters, which of the four typical types of
materials used for monitoring wells would deteriorate the quickest in a
low ph environment? - answer steel.


8. A flush mount well cover should have... - answer ... Concrete in the
base.


9. If decontamination procedures are not followed, what piece(s) of drill
equipment is (are) most likely to contaminate a well? - answer 1. Drill
rods.
2. Augers.
3. Samplers.


10.The purpose for a double cased monitoring well would be... - answer
... To prevent migration of contamination between aquifers.


11.Which of the following is usually added to cement grout to reduce
shrinkage? - answer bentonite.


12.To protect against suspected dust, mist, fumes, and vapors, personnel
should begin operations by having... - answer ... A filtration respirator.

, 13.The site specific safety plan calls for level d ppe. Level d ppe includes... -
answer hard hat, safety glasses, steel toe shoes.


14.When drilling monitoring wells in urban areas, which of the following
should be taken into consideration? - answer 1. Access to drilling
sites.
2. Underground utilities.
3. Overhead utilities.


15.Under what conditions will bentonite pellets not swell to their maximum
size? - answer in highly mineralized water.


16.How far can a well screen section be moved vertically after a filter pack
and bentonite seal have been placed? - answer the length of the filter
pack above the screen.


17.The purpose of taking ground water samples while advancing the hole it...
- answer ... To determine containment concentrations at specific
intervals in the aquifer.


18.What standard method is used for decontaminating equipment and
materials does not belong? - answer lubricate equipment with
petroleum products after cleaning.


19.Which of the following factors can alter the quality of a ground water
sample taken from a monitoring well? - answer 1. Solvent used to
weld pvc casing together.
2. Improperly stored and handled casing.
3. Drilling fluid.


20.Which of the following is not true? - answer the spt is performed by
driving a standard sampler 9 inches into the soil using a 100 lb hammer.

Written for

Institution
NGWA Groundwater
Course
NGWA Groundwater

Document information

Uploaded on
June 16, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Reviews from verified buyers

Showing all reviews
2 months ago

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
jervismuthami Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
10
Member since
1 year
Number of followers
0
Documents
573
Last sold
2 months ago

4.5

2 reviews

5
1
4
1
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions