Arizona Plumbing Exam C-37 (set 4) Questions and Answers Solved Correctly Latest Update What is the name for the measurement taken along the center line of a pipe and fittings? - Answers Developed Length What is the minimum water seal depth on a sand interceptor? - Answers 6 inches What is the minimum diameter of a sump pit being installed in the basement? - Answers 18 inches When installing a pipe that can carry a maximum of 7000 DFU at a slope of 1/16 in per ft, what is the minimum pipe size? - Answers 15 inch diameter How many roof drains are required for a building 300 feet by 50 feet? - Answers 4 What may be added as anti-freeze when fire sprinklers are connected to potable water? - Answers Glycerine Fire sprinkler heads with the brackets color coded green have a maximum ceiling temperature of ______ degrees - Answers 375 An gas supply line using a threaded connection between black iron pipe and plastic pipe is allowed - Answers only outside and underground What is the maximum size of a drilled hole in a 2 x 6 joist, drilled 2feet from the edge? - Answers 1-1/2 inch What is the maximum drainage fixture units of a 6 inch drain line with a slope of 1/8 inch per foot? - Answers 700 Connections for approved embedded piping in concrete hydronic systems shall be connected using all of the following methods except: - Answers threaded All water heaters, including the gas fired solar storage tank type heaters, installed in a seismic zone 3 or 4, shall be strapped at what points on the water heater? - Answers On the upper 1/3 and the lower 1/3 In a solar piping system the valve use to prevent thermal siphonage is called? - Answers Check valve Mechanically formed tee fittings shall be ____? - Answers Brazed After Blue Stake has marked facilities, how many working days are the markings good for? - Answers 15 days Underground utilities are assigned color codes for identification. what color identifies electric power distribution and transmission lines? - Answers Safety Red What is the weight of a gallon of water? - Answers 8.33 pounds A gas pipe is being run through a oversized hole in a concrete wall, what should be done to hole? - Answers Sleeved and sealed On a black iron gas pipe installed in a wood frame wall by boring through the studs, what is the minimum distance from the edge of the stud that a nail plate will be required? - Answers 1-1/2 inches Which of the following is not required as part of a whirlpool bathtub installation - Answers Atmospheric vacuum breaker The minimum height at which a backflow preventer or vacuum breaker is installed above the flood level of a fixture is called. - Answers critical level A gas piping systems demand is 1,000,000 BTU's and has a developed length of 75 feet. The specific gravity is 0.60, with a pressure drop of 0.5 inches of water column. The heating value of the gas is 1000. Using schedule 40 metallic pipe, what minimum pipe size is required to supply this system? (Note: BTU's, developed length, specific gravity, pressure drop and type of pipe can all change, know how to work and use the 35 different tables.) - Answers 2 inch The maximum length of a 2 inch trap arm to its vent shall not exceed _____. - Answers 8 feet When the capacity of an isolated trapped section of a wet fire protection pipe is 10 gallons, what minimum size auxiliary drain valve shall be provided? - Answers 3/4 inch valve with nipple and cap An atmospheric-type vacuum breaker in a potable water line shall be set at least ____ inches above the flood level rim of a fixture or device. - Answers 6 inches A 3/4 inch steel pipe horizontally mounted shall be supported at intervals of no more than? - Answers 12 feet Interceptors and separators shall be maintained how? - Answers Periodic removal of accumulated solids Which is true about fire sprinklers? - Answers Sprinkler with green marking have a temperature classification of very-extra-high What is the maximum size hole allowed in a 2 x 6 exterior wall stud for a 3/4 inch copper tube? -

Content preview

Arizona Plumbing Exam C-37 (set 4) Questions and Answers Solved Correctly Latest Update 2025-2026

What is the name for the measurement taken along the center line of a pipe and fittings? - Answers
Developed Length

What is the minimum water seal depth on a sand interceptor? - Answers 6 inches

What is the minimum diameter of a sump pit being installed in the basement? - Answers 18 inches

When installing a pipe that can carry a maximum of 7000 DFU at a slope of 1/16 in per ft, what is the
minimum pipe size? - Answers 15 inch diameter

How many roof drains are required for a building 300 feet by 50 feet? - Answers 4

What may be added as anti-freeze when fire sprinklers are connected to potable water? - Answers
Glycerine

Fire sprinkler heads with the brackets color coded green have a maximum ceiling temperature of ______
degrees - Answers 375

An gas supply line using a threaded connection between black iron pipe and plastic pipe is allowed -
Answers only outside and underground

What is the maximum size of a drilled hole in a 2 x 6 joist, drilled 2feet from the edge? - Answers 1-1/2
inch

What is the maximum drainage fixture units of a 6 inch drain line with a slope of 1/8 inch per foot? -
Answers 700

Connections for approved embedded piping in concrete hydronic

systems shall be connected using all of the following methods except: - Answers threaded

All water heaters, including the gas fired solar storage tank type heaters, installed in a seismic zone 3 or
4, shall be strapped at what points on the water heater? - Answers On the upper 1/3 and the lower 1/3

In a solar piping system the valve use to prevent thermal siphonage is

called? - Answers Check valve

Mechanically formed tee fittings shall be ____? - Answers Brazed

After Blue Stake has marked facilities, how many working days are the

markings good for? - Answers 15 days

Underground utilities are assigned color codes for identification. what color identifies electric power
distribution and transmission lines? - Answers Safety Red

, What is the weight of a gallon of water? - Answers 8.33 pounds

A gas pipe is being run through a oversized hole in a concrete wall, what should be done to hole? -
Answers Sleeved and sealed

On a black iron gas pipe installed in a wood frame wall by boring through the studs, what is the
minimum distance from the edge of the stud that a nail plate will be required? - Answers 1-1/2 inches

Which of the following is not required as part of a whirlpool bathtub installation - Answers Atmospheric
vacuum breaker

The minimum height at which a backflow preventer or vacuum breaker is installed above the flood level
of a fixture is called. - Answers critical level

A gas piping systems demand is 1,000,000 BTU's and has a developed

length of 75 feet. The specific gravity is 0.60, with a pressure drop of 0.5

inches of water column. The heating value of the gas is 1000. Using

schedule 40 metallic pipe, what minimum pipe size is required to supply this system? (Note: BTU's,
developed length, specific gravity, pressure drop and type of pipe can all change, know how to work and
use the 35 different tables.) - Answers 2 inch

The maximum length of a 2 inch trap arm to its vent shall not exceed _____. - Answers 8 feet

When the capacity of an isolated trapped section of a wet fire protection pipe is 10 gallons, what
minimum size auxiliary drain valve shall be provided? - Answers 3/4 inch valve with nipple and cap

An atmospheric-type vacuum breaker in a potable water line shall be set at least ____ inches above the
flood level rim of a fixture or device. - Answers 6 inches

A 3/4 inch steel pipe horizontally mounted shall be supported at intervals of no more than? - Answers
12 feet

Interceptors and separators shall be maintained how? - Answers Periodic removal of accumulated solids

Which is true about fire sprinklers? - Answers Sprinkler with green marking have a temperature
classification of very-extra-high

What is the maximum size hole allowed in a 2 x 6 exterior wall stud for a 3/4 inch copper tube? -
Answers 2-3/16 inch

A lavatory faucet is 3 inches from a wall and has a 1/2 inch effective opening. What is the required
minimum air gap? - Answers 1 inch

Tanks filled with propane shall not be stored: - Answers within a building

Document information

Uploaded on
June 15, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh
3.4
(74)
Sold
474
Followers
16
Items
32584
Last sold
1 day ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions