100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NICET Level I UPDATED ACTUAL Exam Questions and CORRECT Answers

Rating
-
Sold
-
Pages
11
Grade
A+
Uploaded on
13-06-2025
Written in
2024/2025

NICET Level I UPDATED ACTUAL Exam Questions and CORRECT Answers Fire Alarm Code? - CORRECT ANSWER National Electric Code? - CORRECT ANSWER AHJ? - CORRECT ANSWER - NFPA 72 - NFPA 70 - Authority Having Jurisdiction Disconnecting means for fire alarm power shall be what color? - CORRECT ANSWER Red - If a combination audible visible appliance is installed, the location of the installed appliance shall be determined by the requirements of... - CORRECT ANSWER - The visible appliance

Show more Read less
Institution
NICET
Course
NICET









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NICET
Course
NICET

Document information

Uploaded on
June 13, 2025
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NICET Level I UPDATED ACTUAL Exam
Questions and CORRECT Answers
Fire Alarm Code? - CORRECT ANSWER - NFPA 72



National Electric Code? - CORRECT ANSWER - NFPA 70



AHJ? - CORRECT ANSWER - Authority Having Jurisdiction



Disconnecting means for fire alarm power shall be what color? - CORRECT ANSWER -
Red


If a combination audible visible appliance is installed, the location of the installed appliance shall
be determined by the requirements of... - CORRECT ANSWER - The visible appliance


Two resistors are connected in parallel. Resister one measures 300 ohms and resistor two
measures 300 ohms. What is their equivalent resistance? - CORRECT ANSWER - 150
ohms


Fire warning equipment to be installed in residential occupancies shall produce the audible
emergency evacuation signal described in... - CORRECT ANSWER - ANSI S3.41


The minimum number of restorable fixed temperature spot type heat detectors that must be tested
during each annual test is... - CORRECT ANSWER - Two detectors or more on each
initiating devices circuit


What is the color code requirement for a spot type heat detector rated at 200°F? - CORRECT
ANSWER - White

, Unless otherwise recommended by the manufacturer's published instructions, single and multiple
station smoke alarms installed in one and two family dwellings shall be replaced every... -
CORRECT ANSWER - 10 years from the date of manufacture


When testing a water level supervisory switch serving a pressure tank, a signal shall indicate if
the water level has changed from the required level by... - CORRECT ANSWER - Rising
or falling 3 inches


Fire alarm cables are permitted to be strapped to conduit to support the cable. - CORRECT
ANSWER - False


Where non-powered limited wiring is installed exposed, it must be mechanically protected
within how many feet of the finished floor? - CORRECT ANSWER - 7 feet


According to NFPA 72 visible notification appliances for non-sleeping areas must be mounted
between — and — inches above the finished floor? - CORRECT ANSWER - 80 & 96


If system impairment occurs, the owner must be notified — and within —? - CORRECT
ANSWER - In writing & 24 hours


Conductors returning to the fire alarm control panel from the last field device on the circuit
might indicate what type of circuit? - CORRECT ANSWER - Class A


Secondary power supplies for an EVAC fire alarm system shall be capable of operating for a
minimum of — of standby followed by — of alarm. - CORRECT ANSWER - 24 hours
and 15 minutes


The secondary power supply for protected premises shall automatically provide power within
how many seconds when the primary power fails? - CORRECT ANSWER - 10 seconds


When the temperature exceeds how many degrees Fahrenheit should spot type smoke detectors
not be installed? - CORRECT ANSWER - Above 100°F

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MGRADES Stanford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1072
Member since
1 year
Number of followers
102
Documents
68976
Last sold
2 days ago
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

170 reviews

5
73
4
30
3
45
2
8
1
14

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions