CSLB CONTRACTOR B EXAM (PLUMBING) acid waste piping - Answer- System piping and fittings that are resistant to acid contents usually found in manufacturing processes. aerator - Answer- A device used to mix air and water with water distribution and water conservation in mind; e.g., faucets. air gap (drainage system) - Answer- The unobstructed vertical distance through the free atmosphere between the outlet of a waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging backflow - Answer- Pressure created by any means in the water distribution system, which, by being in excess of the pressure in the water supply mains, causes a potential _________ condition back pressure, low head - Answer- A pressure less than or equal to 4.33 psi (29.88 kPa) or the pressure exerted by a 10-foot (3048 mm), column of water back siphonage - Answer- The backflow of potentially contaminated water into the potable water system as a result of the pressure in the potable water system falling below atmospheric pressure of the plumbing fixtures, pools, tanl‹s, or vats connected to the potable water distribution piping. backwater valve - Answer- A device or valve installed in the building drain or sewer pipe where a sewer is subject to backflow, which prevents drainage or waste from bacl‹ing up into a low level or fixtures and causing a flooding condition. drainage - Answer- A reversal of flow in the drainage system. backflow presenter - Answer- A device or means to prevent the flow water or other liquids, mixtures or substances into the distributing pipe of a potable supply of water, or into any other fixture or appliance from any source other than its intended course. bathroom group - Answer- A group of fixtures consisting of a water closet, lavatory, bathtub or shower, including or excluding a bidet, an emergency floor drain, or both. Such fixtures are located battery of fixtures - Answer- Any group of two or more similar adjacent plumbing fixtures that discharges into a common horizontal waste or soil branch.

Show more Read less
Institution
CSLB CONTRACTOR B
Course
CSLB CONTRACTOR B

Content preview

CSLB CONTRACTOR B EXAM
(PLUMBING)
acid waste piping - Answer- System piping and fittings that are resistant to acid
contents usually found in manufacturing
processes.

aerator - Answer- A device used to mix air and water with water distribution and
water conservation in mind; e.g., faucets.

air gap (drainage system) - Answer- The unobstructed vertical distance through the
free atmosphere between the outlet of a
waste pipe and the flood level rim of the receptacle into which the waste pipe is
discharging

backflow - Answer- Pressure created by any means in the water distribution system,
which, by being in excess of the pressure in the water supply mains, causes a
potential _________ condition

back pressure, low head - Answer- A pressure less than or equal to 4.33 psi (29.88
kPa) or the pressure exerted by a 10-foot
(3048 mm), column of water

back siphonage - Answer- The backflow of potentially contaminated water into the
potable water system as a result of the pressure in the potable water system falling
below atmospheric pressure of the plumbing fixtures, pools, tanl‹s, or vats connected
to the potable water distribution piping.

backwater valve - Answer- A device or valve installed in the building drain or sewer
pipe where a sewer is subject to backflow, which prevents drainage or waste from
bacl‹ing up into a low level or fixtures and causing a flooding condition.

drainage - Answer- A reversal of flow in the drainage system.

backflow presenter - Answer- A device or means to prevent the flow water or other
liquids, mixtures or substances into the distributing pipe of a potable supply of water,
or into any other fixture or appliance from any source other than its intended course.

bathroom group - Answer- A group of fixtures consisting of a water closet, lavatory,
bathtub or shower, including or
excluding a bidet, an emergency floor drain, or both. Such fixtures are located

battery of fixtures - Answer- Any group of two or more similar adjacent plumbing
fixtures that discharges into a common horizontal waste or soil branch.

, bell reducer - Answer- A fitting; shaped like a bell which has one opening of a
smaller diameter used to reduce the size of the pipe in the line, and the opposite
opening of larger diameter.

bell and spigot joint - Answer- Cast-iron piping system comprising a bell that receives
pipe inside and is sealed using molten lead poured over pacl‹ed oakum or rubber
seal gasl‹et.

branch - Answer- Any part of the piping system other than a main, a riser or a stack.

branch water pipe - Answer- That portion of the water distribution system extending,
from a trailer park service main to a trailer site, including the terminal end which
connects to the trailer water supply pipe.

brass connection - Answer- ____ connection is used to connect galvanized iron pipe
to copper pipe.

blazing - Answer- High temperature soldering with alloys that bond to metals in
excess of 840-degrees F.

building drain - Answer- The main horizontal sanitary collection system, inside the
wall line of the building, that conveys sewage to the building sewer which begins 2-
feet (more in some codes), outside the building wall.

building storm drain - Answer- A drain used to receive and convey rain water,
surface water, ground water, subsurface water, and other clear water waste, and
discharge these waste products into a building storm sewer or a combined building
sewer beginning 2-feet outside the building wall

building storm sewer - Answer- The pipe that connects to the end of the building
storm drain to receive and convey its contents to a public storm sewer; combined
sewer, or other approved disposal point.

building subdrain - Answer- Any portion of a drainage system which cannot drain by
gravity into the building sewer.__

building trap - Answer- A device, fitting or assembly of fittings installed in the building
drain to prevent circulation of air between the drainage system of the building and
the building sewer.

check valve - Answer- A one-direction valve that allows flow one way, the check
operated by gravity or spring.

circuit vent - Answer- A vent that serves two or more fixture traps. It connects to a
horizontal branch drain from the downstream side of the highest (last) fixture
connection and then to the vent stack.

cleanout - Answer- An access opening in the drainage system utilized for the
removal of obstructions. Types of _______ included a removal plug or cap, and a
removable fixture or fixture trap.

Written for

Institution
CSLB CONTRACTOR B
Course
CSLB CONTRACTOR B

Document information

Uploaded on
May 27, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Freshy Oxford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
62
Member since
2 year
Number of followers
4
Documents
6986
Last sold
1 month ago

3.6

10 reviews

5
3
4
4
3
1
2
0
1
2

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions