Efficiency of the refrigerant cycle is affected by the operations of the condenser. Of the
following, a more efficient centrifugal compressor operation results from:

Lowering the condensing pressure

The heat removed from the refrigerant in a condenser is:

Sensible and latent heat

The refrigerant unit that you have been assigned to is being taken out of service for a
major repair. You have been assigned to withdraw refrigerant for storage in suitable
containers. According to the NYC Fire Code, you must ensure that the containers:

Are approved by the US Dept. of Transportation

Which of the following best describes how the cylinder unloader works?

Keep in the suction valve opened while the compressor is in the return stroke

In most semi-hermetic compressors, the suction vapor is used to:

Cool the motor

The amount of refrigerant that flows through the orifices of an economizer is determined
by the:

Differences between the high side and low side pressure

The installation of an inline refrigerant cleaning system is advisable:

To remove impurities from the system

The type of refrigerant system that is least likely to leak refrigerant into the building space
that are being cooled:

Indirect system

,The suction pressure of a reciprocating compressor is 65 PSIG. The discharge pressure of
this compressor is 120 PSIG. The atmospheric is 14.7 PSI. The compression ratio for the
given condition is closest to:

1.69

A superheated vapor is:

Dry vapor above the saturation temperature

A refrigerant engineer verifies that a condenser water pump is cavitating. Of the following,
the most likely cause for this condition is:

A faulty cooling tower water level controller

A centrifugal water pump is known as a lift pump when the:

The water supply to the pump suction inlet is below the pump level

A TXV is used to maintain constant:

Evaporator superheat

The chilled water supply to the building is 55 deg F. If the chiller is being used for human
comfort, should you be concerned about this, and why?

Yes, this temp is too high for human comfort purposes

The packing gland of a centrifugal pump serves to:

The drip part of the packing gland gives evidence that there is water in the pump

Capacity control of reciprocating hermetic compressor is typically achieved through:

Operation of the hot gas bypass valve

The most important reason to sub-cool the refrigerant in the condenser is to ensure that:

A pure liquid refrigerant will enter the metering device

, A refrigeration engineer is logging readings from a reciprocating system. Compressor
discharge temperature have dropped significantly and the suction line pressure is high.
Which of the following that may be causing this set of condition?

An expansion valve that is open too wide

A low side float valve is used to maintain:

The level of the refrigerant in the evaporator

Regarding fire safety, which ASHRAE refrigerant safety classification indicates no
flammability and lower toxicity?

A1

When an expansion valve is operating properly, at the end of the evaporator will contain:

Only superheated vapor

What information is not contained in a Material Safety Data Sheet?

Cost of the material

In a steam turbine, what is the function of the Kingsbury thrust bearing?

Maintain axial positioning of the rotor shaft

A centrifugal water pump is considered to the fully primed when?

The pump is full of liquid

Copper tubing refrigerant lines must be installed for a new system. It is a well known
service practice that tubing collapses at bends that must be made, the refrigerant engineer
should use?

Level type tubing bender

A reciprocating compressor is making a knocking sound during operation. If the
refrigerant worn parts are not causing the knocking, what probably the cause?

Slugging of the liquid refrigerant

Document information

Uploaded on
May 26, 2025
Number of pages
27
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QUINTER
3.6
(72)
Sold
408
Followers
106
Items
39866
Last sold
4 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions