100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

CWMS TEST (CONSTRUCTION EDITION) EXAM QUESTIONS AND ANSWERS 100% PASS

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
10-05-2025
Written in
2024/2025

CWMS TEST (CONSTRUCTION EDITION) EXAM QUESTIONS AND ANSWERS 100% PASS ASTM E2886 - ANS Standard for testing ability of exterior vents to resist ember entry NFPA 1142 Standard for Water Supplies for Suburban and Rural Fire Fighting - ANS At minimum every building shall be provided with a water supply meeting requirements of _______________________________. 1) Education 2) Engineering 3) Enforcement - ANS Wildland Fire Mitigation activities fall into what 3 broad categories? 10% - ANS Steepest allowable road grade (without other mitigation measures agreed on by AHJ) NFPA 1143 Standard for Wildland Fire Management - ANS Which NFPA standard provides minimum requirements to fire protection organizations on the management of wildland fire, including prevention, mitigation, preparation and suppression? Solid-core wood no less than 1 3/4 inch thick approved non-combustible material or have a minimum 20 min fire rating - ANS Exterior doors shall be ©THESTAR 2025 ALL RIGHTS RESERVED 13 ft 6 inch vertical Unobstructed width of 20ft - ANS Vertical clearance for roadways and unobstructed width heavy timber, ignition resistant material, fire-retardant treated wood, or have minimum 1 hour fire rated construction material (Unless AHJ declares risk warrants greater protection) - ANS Exterior walls shall be heavy timber construction, non-combustible material, fire-retardant treated wood, other ignition resistant materials, or have a 1 hour fire rating - ANS All projections (balconies, decks, etc) shall be of 5/8 inch sheathing or non-combustible materials - ANS Eaves shall be boxed in with _______________________________________ or _________________________________________. NFPA 1144 Standard for reducing structure ignition hazards from wildland fire - ANS Standard which provides a methodology for assessing wildland fire ignition hazards around existing structure, residential developments and subdivisions and provides minimum requirements for new construction to reduce the potential of structure ignition from wildland fires 6 Inches - ANS Minimum non-combustible space between horizontal surface and siding. Intermediate Zone - ANS Extends out 30ft from foundation, deck, etc. Wildland Urban Interface - ANS Area where wildland fuels abut structures with clear line of demarcation between residential, business and public structures and wildland fuels Class B - ANS Minimum Fire Rating (Class) for exterior wall materials

Show more Read less
Institution
CWMS
Course
CWMS









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
CWMS
Course
CWMS

Document information

Uploaded on
May 10, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©THESTAR 2025 ALL RIGHTS RESERVED




CWMS TEST (CONSTRUCTION
EDITION) EXAM QUESTIONS AND
ANSWERS 100% PASS



ASTM E2886 - ANS Standard for testing ability of exterior vents to resist ember entry


NFPA 1142 Standard for Water Supplies for Suburban and Rural Fire Fighting - ANS At
minimum every building shall be provided with a water supply meeting requirements of
_______________________________.


1) Education
2) Engineering

3) Enforcement - ANS Wildland Fire Mitigation activities fall into what 3 broad categories?


10% - ANS Steepest allowable road grade (without other mitigation measures agreed on by
AHJ)


NFPA 1143 Standard for Wildland Fire Management - ANS Which NFPA standard provides
minimum requirements to fire protection organizations on the management of wildland fire,
including prevention, mitigation, preparation and suppression?


Solid-core wood no less than 1 3/4 inch thick
approved non-combustible material

or have a minimum 20 min fire rating - ANS Exterior doors shall be

, ©THESTAR 2025 ALL RIGHTS RESERVED



13 ft 6 inch vertical

Unobstructed width of 20ft - ANS Vertical clearance for roadways and unobstructed width


heavy timber, ignition resistant material, fire-retardant treated wood, or have minimum 1 hour
fire rated construction material (Unless AHJ declares risk warrants greater protection) -
ANS Exterior walls shall be


heavy timber construction, non-combustible material, fire-retardant treated wood, other
ignition resistant materials, or have a 1 hour fire rating - ANS All projections (balconies,
decks, etc) shall be of


5/8 inch sheathing or non-combustible materials - ANS Eaves shall be boxed in with
_______________________________________ or
_________________________________________.


NFPA 1144

Standard for reducing structure ignition hazards from wildland fire - ANS Standard which
provides a methodology for assessing wildland fire ignition hazards around existing structure,
residential developments and subdivisions and provides minimum requirements for new
construction to reduce the potential of structure ignition from wildland fires


6 Inches - ANS Minimum non-combustible space between horizontal surface and siding.


Intermediate Zone - ANS Extends out 30ft from foundation, deck, etc.


Wildland Urban Interface - ANS Area where wildland fuels abut structures with clear line of
demarcation between residential, business and public structures and wildland fuels


Class B - ANS Minimum Fire Rating (Class) for exterior wall materials

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar Florida State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
611
Member since
2 year
Number of followers
178
Documents
24049
Last sold
22 hours ago
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

121 reviews

5
58
4
21
3
21
2
4
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions